文献速递关节外科

50岁及以下患者钴铬股骨头与高交联聚乙烯全髋关节置换术十五年结果

Fifteen-Year Results of Total Hip Arthroplasty With Cobalt-Chromium Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years and Less.
PubMed 文献 · J Arthroplasty · 2019-02-05

回顾性分析82例(89髋)50岁及以下初次全髋关节置换术患者,使用高交联聚乙烯髋臼内衬与钴铬股骨头。平均15年随访无磨损相关翻修,线性磨损率0.0185 mm/y,患者报告结局显著改善,无骨溶解影像学改变。

要点

  • 平均15年无翻修生存率97.8%,无磨损相关翻修。
  • 线性磨损率0.0185 mm/y(标准差0.05),容积磨损率12.80 mm3/y(标准差22.69),临床不可检测。
  • 改良Harris髋关节评分改善35.3(22.5),P < .0001;UCLA活动评分中位数6.0,P < .0001。

核心结论

  • 15年随访显示,该年轻队列中高交联聚乙烯轴承磨损性能优异,维持了良好的临床改善,且无磨损相关翻修手术。
  • 高交联聚乙烯与钴铬轴承组合在50岁以下患者初次全髋关节置换术后15年仍极为有效。

研究设计与样本

  • 回顾性研究,基于前瞻性纵向队列,纳入82例连续患者(89髋)接受初次全髋关节置换术,使用高交联聚乙烯髋臼内衬和钴铬股骨头。
  • 手术时平均年龄38.8岁(范围12-50),所有患者均通过后路入路接受非骨水泥髋臼组件与钴铬股骨头及非骨水泥股骨组件,所有组件来自单一制造商。
  • 记录加州大学洛杉矶分校活动评分和改良Harris髋关节评分,磨损计算使用Martell髋关节分析套件(版本8.0.4.3)。

主要发现

  • 平均15年(范围13.1-18.5)随访,高交联聚乙烯组无翻修生存率为97.8%,无磨损相关翻修。
  • 扣除1年磨合期后,线性磨损率为0.0185 mm/y(标准差0.05),容积磨损率为12.80 mm3/y(标准差22.69),登记为临床不可检测,与同队列早期时间点的稳态磨损率相当。
  • 未发现 concerning 骨溶解的影像学改变。
  • 改良Harris髋关节评分改善35.3(22.5),P < .0001;加州大学洛杉矶分校活动评分中位数6.0,P < .0001。

关键数值与推荐

  • 无翻修生存率97.8%(平均15年随访)。
  • 线性磨损率0.0185 mm/y(标准差0.05),容积磨损率12.80 mm3/y(标准差22.69)。
  • 改良Harris髋关节评分改善35.3(22.5),P < .0001;加州大学洛杉矶分校活动评分中位数6.0,P < .0001。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Highly cross-linked polyethylene (HXLPE) is the most commonly used bearing surface in total hip arthroplasty (THA) because of its superior wear properties, but long-term results in young patients are limited. Mid-term survivorship has been promising; however, polyethylene wear rates and need for revision surgeries remain a concern in this population. The purpose of our study is to investigate polyethylene wear rates, implant survivorship, wear-related revisions, and patient-reported outcomes in a young patient cohort at 15-year follow-up. METHODS: We performed a retrospective study of a prospective longitudinal cohort of 82 consecutive patients (89 hips) who underwent primary THA with an HXLPE acetabular liner and a cobalt-chromium femoral head. The mean age at the time of surgery for the cohort was 38.8 years (range 12-50). All patients received HXLPE liners with a cementless acetabular component coupled with a cobalt-chrome femoral head through a posterior approach with a cementless femoral component. All components were from a single manufacturer. We recorded University of California, Los Angeles Activity, and modified Harris Hip Scores. Wear calculations were made using the Martell Hip Analysis Suite (Version 8.0.4.3). RESULTS: At average 15 years (range 13.1-18.5), there was a revision-free survivorship of 97.8% in our HXLPE group with no wear-related revisions. We observed a linear wear rate of 0.0185 mm/y (standard deviation 0.05) after accounting for a 1-year bedding-in period. The volumetric wear rate was found to be 12.80 mm3/y (standard deviation 22.69). These numbers are registered as clinically undetectable and are comparable to steady state wear rates in the same cohort of patients at earlier time points. We found no radiographic changes concerning osteolysis. We observed excellent patient-reported outcomes at this time point with improvements in modified Harris Hip Scores (35.3 [22.5], P < .0001) and University of California, Los Angeles Activity Scores (median 6.0, P < .0001). CONCLUSION: At 15-year follow-up, we demonstrated that HXLPE bearings in this young cohort had excellent wear properties, maintained superior clinical improvements, and underwent no wear-related revision operations. The HXLPE and cobalt-chrome bearing couple continues to be extremely effective 15 years after primary THA in patients less than 50 years. LEVEL OF EVIDENCE: IV.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Rames RD, Stambough JB, Pashos GE, et al. Fifteen-Year Results of Total Hip Arthroplasty With Cobalt-Chromium Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years and Less. J Arthroplasty. 2019. PMID: 30808529. doi:10.1016/j.arth.2019.01.071

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。