轻度冠状面股骨柄对线不良对双锥度非骨水泥初次全髋关节置换术的假体生存率或临床结果无负面影响
该研究纳入2005至2010年间1028例使用两种现代双锥度近端涂层非骨水泥股骨柄的初次全髋关节置换术,评估冠状面中立位对线(0°±3°)是否改善远期假体生存率;978例(95%)股骨柄位于中立位范围内,50例(5%)为对线不良(外翻3.1°至内翻4.8°);结果显示两组假体生存率、Harris髋关节评分、大腿疼痛及脱位发生率均无显著差异。
要点
- 轻度冠状面对线不良(外翻3.1°至内翻4.8°)未显著影响非骨水泥双锥度股骨柄的假体生存率。
- 对线不良组与中立位组的Harris髋关节评分相似(均为89分,P=0.84)。
- 两组轻中度大腿疼痛发生率(6.1% vs 6%,P=0.85)和脱位发生率(P=0.77)均无显著差异。
核心结论
- 现代双锥度非骨水泥全髋关节置换股骨柄的轻度对线不良似乎不会对假体生存率或临床结果产生负面影响,这与骨水泥股骨柄相反。
研究设计与样本
- 2005年至2010年间共实施1028例初次全髋关节置换术,使用两种现代双锥度近端涂层非骨水泥股骨柄。
- 术后即刻及末次随访时测量对线,978例股骨柄(95%)位于中立解剖冠状轴0°±3°范围内,50例(5%)超出该范围被视为对线不良(外翻3.1°至内翻4.8°)。
- 分析指标包括假体生存率、Harris髋关节评分和脱位发生率,平均随访5年。
- 证据等级III:病例对照研究。
主要发现
- 无无菌性股骨假体松动生存率在中立位组5年和8年分别为99.3%和98.2%,对线不良组5年和8年均为100%(P=0.98)。
- 无任何原因股骨假体翻修生存率在中立位组5年和8年分别为99.1%和97.3%,对线不良组5年和8年均为100%(P=0.80)。
- 末次随访时Harris髋关节评分两组相似(均为89分;P=0.84)。
- 轻中度大腿疼痛发生率两组相似(6.1% vs 6%,P=0.85)。
- 8年时脱位发生率为1.5%,两组间相似(P=0.77)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Proper component positioning in total hip arthroplasty (THA) is crucial for implant fixation and hip stability. The purpose of this study is to assess if neutral coronal stem alignment (0° ± 3°) improved long-term survivorship in uncemented femoral components. METHODS: Between 2005 and 2010, 1028 primary THAs were performed with 2 contemporary dual-tapered, proximally coated uncemented stem types. Alignment was measured immediately postoperatively and at most recent follow-up. In total, 978 femoral stems (95%) were within 0° ± 3° of the neutral anatomic coronal axis, and the 50 stems (5%) outside that range were considered outliers (3.1° of valgus to 4.8° of varus). Outcomes analyzed included implant survivorship, Harris Hip Scores, and incidence of dislocation. Mean follow-up was 5 years. RESULTS: Survivorship free of aseptic femoral component loosening was 99.3% and 98.2% at 5 and 8 years in the neutral group vs 100% at 5 and 8 years in the outlier group (P = .98). Survivorship free of femoral component revision for any reason was 99.1% and 97.3% at 5 and 8 years vs 100% at 5 and 8 years, respectively (P = .80). Harris Hip Scores were similar (89 in both groups; P = .84) at most recent follow-up. The incidence of mild to moderate thigh pain was also similar in both groups (6.1% vs 6%, P = .85). The incidence of dislocation was 1.5% at 8 years, and similar between both groups (P = .77). CONCLUSION: Slight malalignment of contemporary dual-tapered uncemented THA femoral components does not appear to negatively impact survivorship or clinical outcomes, which is in contrast to cemented femoral components. LEVEL OF EVIDENCE III: Case-control study.
引用
- Reina N, Salib CG, Perry KI, et al. Mild Coronal Stem Malalignment Does Not Negatively Impact Survivorship or Clinical Results in Uncemented Primary Total Hip Arthroplasties With Dual-Tapered Implants. J Arthroplasty. 2019. PMID: 30773361. doi:10.1016/j.arth.2019.01.055
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。