后稳定型旋转平台全膝关节置换术中假体几何形状对髌骨力学的影响
这项在体生物力学研究比较了后稳定型旋转平台全膝关节置换术中解剖型与穹顶型髌骨假体患者的运动学、功能、力量和患者报告结局。两组膝关节活动度和满意度相似,但解剖型组伸膝力量平均比穹顶型组高36%,且在负重弓步时髌骨相对股骨屈曲更大、外旋更小。
要点
- 两组患者术后膝关节功能活动度和患者报告结局及满意度相似。
- 解剖型髌骨假体组伸膝力量平均比穹顶型组高36%。
- 负重弓步时解剖型组髌骨相对股骨屈曲显著更大、外旋更低。
核心结论
- 相对于改良穹顶几何形状,解剖型髌骨几何形状患者获得更大的髌骨屈曲,可能更好地复制正常髌骨运动。
- 由于髌骨假体设计的几何差异,解剖型假体患者可能比穹顶型假体患者恢复更多的伸膝力量。
研究设计与样本
- 在体生物力学研究,纳入年龄、性别和体重指数匹配的旋转平台全膝关节置换术后患者,穹顶型髌骨假体组16例,解剖型髌骨假体组16例。
- 在人体运动实验室使用高速立体放射摄影术,于无负重坐位伸膝和负重弓步活动中测试。
主要发现
- 两组患者获得相似的功能性膝关节活动度,报告相似的结局和满意度。
- 解剖型假体组患者伸膝力量平均比穹顶型组高36%。
- 负重弓步活动中,解剖型髌骨假体组患者髌骨相对股骨屈曲显著更大,外旋更低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Patellofemoral complications may cause pain and discomfort, sometimes leading to revision surgery for total knee arthroplasty patients, and patellar implant design has an impact on function of the reconstructed knee. The purpose of this in vivo biomechanics study was to understand the kinematic, functional, strength, and patient-reported outcome data of patients with anatomic and dome patellar implants. METHODS: Satisfactory age-matched, gender-matched, and body mass index-matched patients who underwent rotating-platform total knee arthroplasty from one joint replacement system with either dome (n = 16) or anatomic (n = 16) patellar components were tested in a human motion laboratory using high-speed stereoradiography during an unweighted seated knee extension and a weight-bearing lunge activity. Patellar kinematics, range of motion, strength, and patient-reported outcomes were compared between subjects with anatomic or dome component geometry. RESULTS: Both groups of patients achieved similar functional knee range of motion and reported similar outcomes and satisfaction. On average, patients with the anatomic component had 36% greater extensor strength compared with dome subjects. Patients with anatomic patellar components demonstrated significantly greater flexion of the patella relative to the femur and lower external rotation during the weighted lunge activity. CONCLUSIONS: Relative to the modified dome geometry, patients with anatomic patellar geometry achieved greater patellar flexion which may better replicate normal patellar motion. Patients with anatomic implants may regain more extensor strength compared to patients with dome implants due to geometric differences in the patellar component designs.
引用
- Mannen EM, Ali AA, Dennis DA, et al. Influence of Component Geometry on Patellar Mechanics in Posterior-Stabilized Rotating Platform Total Knee Arthroplasty. J Arthroplasty. 2019. PMID: 30777625. doi:10.1016/j.arth.2019.01.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。