上关节囊重建增强关节镜下肩袖修补可改善肩袖完整性
研究纳入34例严重退变但可修复的肩袖撕裂患者,在关节镜下肩袖修补前以上关节囊重建(SCR)用阔筋膜自体移植增强,并与91例单纯关节镜下肩袖修补患者比较。SCR组术后无再撕裂且无III型肩袖完整性,单纯修补组再撕裂发生率为4%(4/91)、III型肩袖完整性发生率为8%;两组功能评分与活动度均改善且术后无差异。
要点
- SCR增强组34例术后无再撕裂、无III型肩袖完整性,单纯修补组再撕裂4%(4/91)、III型8%。
- 两组ASES、JOA评分及主动活动度均较术前改善(P < .001),术后组间无差异。
- SCR组冈上肌Goutallier分级均值2.8高于单纯修补组2.1(P < .0001),仍获更好肩袖完整性。
核心结论
- 关节镜下肩袖修补前以上关节囊重建增强可预防术后1年再撕裂,并改善MRI上修复肌腱的质量。
- 尽管接受SCR增强的患者撕裂肌腱退变更重,两组功能结局相似。
研究设计与样本
- 队列研究,证据等级3级。
- SCR增强组为34例连续患者(平均年龄69.1岁),肩袖撕裂严重退变但可修复,在关节镜下肩袖修补前以阔筋膜自体移植行SCR增强。
- 所有撕裂为中型(1-3 cm)或大型(3-5 cm);撕裂肌腱数量为2条(冈上肌和冈下肌)者29肩,3条(冈上肌、冈下肌和肩胛下肌)者5肩。
- 对照组为91例连续中型或大型肩袖撕裂患者(平均年龄63.6岁),接受单纯关节镜下肩袖修补。
- 比较ASES评分、JOA评分、肩关节主动活动度及肩袖完整性(Sugaya MRI分类),采用t检验和卡方检验,比较SCR增强与单纯修补组间及术前与末次随访。
主要发现
- SCR增强组34例均无术后再撕裂,也无III型肩袖完整性;单纯修补组再撕裂发生率为4%(4/91),III型肩袖完整性发生率为8%。
- 两组ASES评分、JOA评分、主动前屈、主动外旋和主动内旋均较术前增加(P < .001)。
- 术后ASES评分和主动活动度组间无差异,但SCR增强组冈上肌Goutallier分级均值2.8高于单纯修补组均值2.1(P < .0001)。
关键数值与推荐
- 肩袖完整性以Sugaya MRI分类评估,SCR增强组无III型,单纯修补组III型发生率为8%。
- 再撕裂:SCR增强组0例,单纯修补组4%(4/91)。
- 冈上肌Goutallier分级均值:SCR增强组2.8 vs 单纯修补组2.1(P < .0001)。
- ASES评分、JOA评分及主动活动度术前至末次随访均改善(P < .001),术后组间无差异。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Retear of repaired rotator cuff tendons worsens patient outcome and decreases patient satisfaction. Superior capsule reconstruction (SCR) was developed to center the humeral head and thus restore the force couple for patients with rotator cuff tears. PURPOSE: To evaluate whether SCR for reinforcement before arthroscopic rotator cuff repair (ARCR) improves cuff integrity. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: Thirty-four consecutive patients (mean age, 69.1 years) with severely degenerated but reparable rotator cuff tears underwent SCR with fascia lata autografts for reinforcement before ARCR. All tears were medium (1-3 cm) or large (3-5 cm), and the number of torn tendons was 2 (supraspinatus and infraspinatus) in 29 shoulders and 3 (supraspinatus, infraspinatus, subscapularis) in 5 shoulders. To assess the benefit of SCR for reinforcement, all data were compared with those after ARCR alone among 91 consecutive patients with medium or large rotator cuff tears (mean age, 63.6 years). The American Shoulder and Elbow Surgeons (ASES) and Japanese Orthopaedic Association (JOA) scores, active shoulder range of motion, and cuff integrity (Sugaya magnetic resonance imaging classification) were compared ( t test and chi-square test) between ARCR with and without SCR, as well as before surgery and at final follow-up. RESULTS: All 34 patients who underwent SCR before ARCR had neither postoperative retear nor type III cuff integrity, whereas those treated with ARCR alone had a 4% incidence (4 of 91) of retear and 8% incidence of type III cuff integrity. ASES and JOA scores, active elevation, active external rotation, and active internal rotation increased in both treatment groups ( P < .001). Postoperative ASES score and active range of motion did not differ between groups, although the Goutallier grade of the supraspinatus was higher for ARCR with SCR (mean, 2.8) than ARCR alone (mean, 2.1; P < .0001). CONCLUSION: SCR for reinforcement prevented retear at 1 year after ARCR and improved the quality of the repaired tendon on magnetic resonance imaging. Functional outcomes were similar between groups, even though degeneration of the torn tendons was greater among patients who underwent ARCR with SCR.
引用
- Mihata T, Lee TQ, Hasegawa A, et al. Superior Capsule Reconstruction for Reinforcement of Arthroscopic Rotator Cuff Repair Improves Cuff Integrity. Am J Sports Med. 2018. PMID: 30596519. doi:10.1177/0363546518816689
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。