切口负压伤口治疗装置改善髋膝关节置换术后短期伤口并发症但不降低远期感染率
一项前瞻性随机对照试验纳入398例初次或翻修下肢全关节置换患者,比较切口负压伤口治疗(iNPWT)与常规敷料。iNPWT组第7天伤口渗液报告更多(P=0.01),但渗液持续超过14天更少(P=0.04);全髋置换患者第7天渗液显著更高(P=0.04)。全膝置换且BMI>35 kg/m²患者中iNPWT组并发症更少(1.3% vs 21.6%,P<0.01)。两组远期表浅或深部感染率无显著差异(4.0% vs 3.4%,P=0.8)。
要点
- iNPWT组第7天伤口渗液报告更多(P=0.01),但渗液超过14天更少(P=0.04)。
- 全膝置换且BMI>35 kg/m²患者iNPWT组并发症1.3% vs 常规敷料21.6%(P<0.01)。
- 两组远期表浅或深部感染率无显著差异(iNPWT 4.0% vs 常规敷料3.4%,P=0.8)。
核心结论
- 研究结果支持使用iNPWT装置可改善软组织愈合反应。
- 术后伤口渗液可能限制iNPWT在全髋关节置换术后的价值,但切口负压伤口治疗装置可能对BMI>35 kg/m²的择期全膝关节置换患者有针对性获益。
- 作者认为针对这一更高风险患者群体的专门研究可能有助于明确iNPWT的价值。
研究设计与样本
- 前瞻性随机对照试验,纳入398例接受初次或翻修下肢全关节置换术的患者,随机分为iNPWT组或常规伤口敷料组。
- 术后第7、14、35天评估伤口愈合和早期并发症发生率;平均2年随访时确定远期感染率。
主要发现
- iNPWT组患者第7天报告伤口渗液的可能性更高(P=0.01),但渗液持续超过14天的可能性更低(P=0.04)。
- 全髋关节置换患者第7天伤口渗液在iNPWT组显著更高(P=0.04),但差异未在其他时间间隔持续。
- 全膝关节置换且BMI>35 kg/m²患者中,iNPWT组并发症更少(1.3% vs 21.6%,P<0.01),敷料相关顾虑更少(1.3% vs 10.8%,P=0.02)。
- iNPWT组与常规敷料组远期表浅或深部感染率无显著差异(4.0% vs 3.4%,P=0.8)。
关键数值与推荐
- 全膝关节置换且BMI>35 kg/m²患者:iNPWT组并发症1.3% vs 常规敷料组21.6%(P<0.01)。
- 全膝关节置换且BMI>35 kg/m²患者:iNPWT组敷料相关顾虑1.3% vs 常规敷料组10.8%(P=0.02)。
- 远期表浅或深部感染率:iNPWT组4.0% vs 常规敷料组3.4%(P=0.8),无显著差异。
临床怎么用
- 作者认为iNPWT装置可能对BMI>35 kg/m²的择期全膝关节置换患者有针对性获益。
- 作者指出术后伤口渗液可能限制iNPWT在全髋关节置换术后的价值。
- 作者认为针对更高风险患者群体的专门研究可能有助于明确iNPWT的价值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The potential value of incisional negative pressure wound therapy (iNPWT) on lower extremity total joint arthroplasty (TJA) wound healing has been supported in a few retrospective studies. We performed this prospective, randomized, controlled trial to assess the impact of iNPWT on wound appearance, early complications, and late infection rates following hip and knee TJA compared with a standard surgical dressing. METHODS: Three-hundred ninety-eight patients undergoing primary or revision lower extremity TJA were randomized into iNPWT or conventional wound dressing groups. Wound healing and early complication rates were assessed at 7, 14, and 35 days after the index surgery. Late infection rates were determined at a mean 2-year follow-up. RESULTS: Patients treated with an iNPWT device were more likely to report wound drainage at day 7 (P = .01), but less drainage longer than 14 days (P = .04). Wound drainage was significantly higher for total hip arthroplasty patients at day 7 (P = .04), but differences were not sustained through the other time intervals. Total knee arthroplasty patients with a body mass index > 35 kg/m2 treated with an iNPWT device experienced fewer complications (1.3% vs 21.6%, P < .01) and fewer dressing-related concerns (1.3% vs 10.8%, P = .02) compared with a conventional dressing. No significant difference in late superficial or deep infection rates was identified between iNPWT and conventional dressing groups (4.0% vs 3.4%, P = .8). CONCLUSION: Our study findings support improved soft tissue healing response with the use of iNPWT devices. While postoperative wound drainage may limit their value following total hip arthroplasty, incisional NPWT devices may have a targeted benefit for elective total knee arthroplasty patients with a body mass index > 35 kg/m2. Specific study in this higher-risk patient group may be helpful to define the value of iNPWT.
引用
- Keeney JA, Cook JL, Clawson SW, et al. Incisional Negative Pressure Wound Therapy Devices Improve Short-Term Wound Complications, but Not Long-Term Infection Rate Following Hip and Knee Arthroplasty. J Arthroplasty. 2018. PMID: 30612833. doi:10.1016/j.arth.2018.12.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。