文献速递关节外科

传统与机器人臂辅助单髁膝关节置换术早期功能康复及出院评估:一项前瞻性队列研究

An assessment of early functional rehabilitation and hospital discharge in conventional versus robotic-arm assisted unicompartmental knee arthroplasty: a prospective cohort study.
PubMed 文献 · Bone Joint J · 2019-01-01

前瞻性队列研究纳入146例症状性内侧间室膝骨关节炎行初次单髁膝关节置换术的患者,由单一术者分别采用传统胫骨导向活动平台假体(73例)和机器人臂辅助固定平台假体(73例)。机器人臂辅助组术后疼痛减轻、阿片类镇痛需求减少、直腿抬高时间缩短、物理治疗次数减少、出院时最大膝关节屈曲度增加,平均出院时间缩短(42.5小时 vs 71.1小时,p<0.001);两组90天内术后并发症无差异。

要点

  • 机器人臂辅助单髁膝关节置换术较传统胫骨导向术式减轻术后疼痛并减少阿片类镇痛需求(p<0.001)。
  • 机器人臂辅助组直腿抬高时间更短、物理治疗次数更少、出院时最大膝关节屈曲度更大(p<0.001)。
  • 机器人臂辅助组平均出院时间42.5小时(sd 5.9)较传统组71.1小时(sd 14.6)缩短(p<0.001),90天内并发症无差异。

核心结论

  • 与传统胫骨导向单髁膝关节置换术相比,机器人臂辅助单髁膝关节置换术与术后疼痛减轻、阿片类镇痛需求减少、早期功能康复改善及出院时间缩短相关。

研究设计与样本

  • 前瞻性队列研究,纳入146例症状性内侧间室膝骨关节炎行初次单髁膝关节置换术的患者,由单一术者完成手术。
  • 73例连续患者接受传统胫骨导向活动平台单髁膝关节置换术,随后73例连续患者接受机器人臂辅助固定平台单髁膝关节置换术。
  • 所有手术均采用标准内侧髌旁入路,所有患者接受相同的术后康复方案;术后疼痛数字评分、阿片类镇痛消耗量、达到预设功能康复结局的时间、出院时间及术后并发症由独立观察者记录。

主要发现

  • 与传统胫骨导向单髁膝关节置换术相比,机器人臂辅助单髁膝关节置换术与术后疼痛减轻相关(p<0.001)。
  • 与传统胫骨导向单髁膝关节置换术相比,机器人臂辅助单髁膝关节置换术与阿片类镇痛需求减少相关(p<0.001)。
  • 与传统胫骨导向单髁膝关节置换术相比,机器人臂辅助单髁膝关节置换术与直腿抬高时间缩短(p<0.001)、物理治疗次数减少(p<0.001)及出院时最大膝关节屈曲度增加(p<0.001)相关。
  • 机器人臂辅助组平均出院时间为42.5小时(sd 5.9),传统胫骨导向组为71.1小时(sd 14.6),机器人臂辅助组较传统组缩短(p<0.001)。
  • 两组在90天随访期内术后并发症无差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The objectives of this study were to compare postoperative pain, analgesia requirements, inpatient functional rehabilitation, time to hospital discharge, and complications in patients undergoing conventional jig-based unicompartmental knee arthroplasty (UKA) versus robotic-arm assisted UKA. PATIENTS AND METHODS: This prospective cohort study included 146 patients with symptomatic medial compartment knee osteoarthritis undergoing primary UKA performed by a single surgeon. This included 73 consecutive patients undergoing conventional jig-based mobile bearing UKA, followed by 73 consecutive patients receiving robotic-arm assisted fixed bearing UKA. All surgical procedures were performed using the standard medial parapatellar approach for UKA, and all patients underwent the same postoperative rehabilitation programme. Postoperative pain scores on the numerical rating scale and opiate analgesia consumption were recorded until discharge. Time to attainment of predefined functional rehabilitation outcomes, hospital discharge, and postoperative complications were recorded by independent observers. RESULTS: Robotic-arm assisted UKA was associated with reduced postoperative pain (p < 0.001), decreased opiate analgesia requirements (p < 0.001), shorter time to straight leg raise (p < 0.001), decreased number of physiotherapy sessions (p < 0.001), and increased maximum knee flexion at discharge (p < 0.001) compared with conventional jig-based UKA. Mean time to hospital discharge was reduced in robotic UKA compared with conventional UKA (42.5 hours (sd 5.9) vs 71.1 hours (sd 14.6), respectively; p < 0.001). There was no difference in postoperative complications between the two groups within 90 days' follow-up. CONCLUSION: Robotic-arm assisted UKA was associated with decreased postoperative pain, reduced opiate analgesia requirements, improved early functional rehabilitation, and shorter time to hospital discharge compared with conventional jig-based UKA.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Kayani B, Konan S, Tahmassebi J, et al. An assessment of early functional rehabilitation and hospital discharge in conventional versus robotic-arm assisted unicompartmental knee arthroplasty: a prospective cohort study. Bone Joint J. 2019. PMID: 30601042. doi:10.1302/0301-620X.101B1.BJJ-2018-0564.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。