文献速递关节外科

计算机辅助与传统全膝关节置换术功能结局比较:高质量前瞻性研究的系统综述与Meta分析

Comparison of Functional Outcomes of Computer-Assisted vs Conventional Total Knee Arthroplasty: A Systematic Review and Meta-Analysis of High-Quality, Prospective Studies.
PubMed 文献 · J Arthroplasty · 2018-12-02

该系统综述与Meta分析纳入18项前瞻性研究共3060膝,比较计算机辅助导航全膝关节置换术(CAS-TKA)与传统TKA的功能结局。在5至8年随访时,CAS-TKA组的西安大略和麦克马斯特大学骨关节炎指数(WOMAC)评分(P < .001)与膝关节学会功能评分(KSS-function)(P = .03)优于传统TKA组;其余随访时段两组无差异。作者结论为CAS-TKA在5至8年随访改善功能结局的证据有限,需更多大样本、更长随访的前瞻性研究支持。

要点

  • 共纳入18项前瞻性研究、3060膝,CAS-TKA组1538膝,传统TKA组1522膝。
  • 5至8年随访时CAS-TKA组WOMAC评分(P < .001)与KSS-function评分(P = .03)优于传统TKA组。
  • 其余随访时段两组功能结局无差异。

核心结论

  • Meta分析结论为CAS-TKA在5至8年随访改善WOMAC与KSS-function评分的证据有限。
  • 需更多大样本、更长随访的前瞻性研究支持CAS趋向更好功能结局。

研究设计与样本

  • 系统综述与Meta分析,按PRISMA指南进行,检索PubMed、Embase、灰色文献及clinicaltrials.gov至2018年4月30日。
  • 纳入仅1级和2级的前瞻性原始研究,比较CAS-TKA与传统TKA功能结局,最短随访2年。
  • 共纳入18项研究、3060膝,其中CAS-TKA组1538膝,传统TKA组1522膝;研究按随访时间分组:≥2年至<5年、≥5年至<8年、>8年。
  • 研究问题与纳入标准事先设定,提取相关数据并使用随机效应模型。

主要发现

  • 5至8年随访时,CAS-TKA组汇总平均WOMAC评分优于传统TKA组(P < .001)。
  • 5至8年随访时,CAS-TKA组汇总平均KSS-function评分优于传统TKA组(P = .03)。
  • 其余随访时段两组功能结局无差异。

关键数值与推荐

  • 纳入研究仅为1级和2级前瞻性原始研究。
  • 纳入研究最短随访2年。
  • 5至8年随访时WOMAC评分组间比较P < .001。
  • 5至8年随访时KSS-function评分组间比较P = .03。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 作者结论指出CAS-TKA改善功能结局的证据有限。
  • 需更多大样本、更长随访的前瞻性研究支持CAS趋向更好功能结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Computer-assisted navigation system (CAS) in total knee arthroplasty (TKA) has been shown to improve mechanical alignment and prosthesis positioning as compared to conventional TKA. However, the evidence with regard to whether CAS-TKA has better patient function over conventional TKA is not clear. This systematic review and meta-analysis compares functional outcomes of CAS vs conventional TKA at longer follow-up periods. METHODS: This study was conducted in accordance with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. PubMed, Embase, gray literature, and clinicaltrials.gov were searched up to April 30, 2018. All prospective original studies (only level 1 and 2) that compared functional outcomes of CAS-TKA vs conventional TKA, with minimum 2-year follow-up, were included. The research question and eligibility criteria were established a priori. Pertinent data were extracted and random-effects model was used. RESULTS: A total of 18 studies with 3060 knees were included; of which 1538 underwent TKA with CAS and 1522 underwent conventional TKA. Studies were grouped based on the follow-up reported into: (1) ≥2 years to <5 years; (2) ≥5 years to <8 years; (3) >8 years. Pooled mean Western Ontario and McMaster Universities Osteoarthritis Index scores (P < .001) and Knee Society Score-function score (P = .03) were better in the CAS-TKA group in the 5- to 8-year follow-up. For the remaining follow-ups, there was no difference between the 2 groups. CONCLUSION: The meta-analysis concluded that there is limited evidence that CAS-TKA improves functional outcomes at 5- to 8-year follow-up as measured by Western Ontario and McMaster Universities Osteoarthritis Index and Knee Society Score-function scores. More prospective studies with larger sample size and longer-term follow-up are required to support the trend toward better functional outcomes with CAS.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Panjwani TR, Mullaji A, Doshi K, et al. Comparison of Functional Outcomes of Computer-Assisted vs Conventional Total Knee Arthroplasty: A Systematic Review and Meta-Analysis of High-Quality, Prospective Studies. J Arthroplasty. 2018. PMID: 30611520. doi:10.1016/j.arth.2018.11.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。