双动髋臼杯对原发性全髋关节置换术后因骨关节炎翻修风险的影响:基于北欧关节置换登记协会数据库的配对人群研究
基于北欧关节置换登记协会数据库的配对人群研究,比较双动髋臼杯(DMC)与金属对聚乙烯(MoP)或陶瓷对聚乙烯(CoP)轴承初次全髋关节置换术后的翻修风险。共匹配2277例DMC患者与2277例MoP/CoP患者。DMC组总体翻修风险无显著差异(调整HR=1.18;95%CI 0.87-1.62),但脱位翻修风险更低(调整HR=0.09;95%CI 0.03-0.29),感染翻修风险更高(调整HR=3.20;95%CI 1.49-6.85)。
要点
- DMC组与MoP/CoP组总体翻修风险无显著差异(调整HR=1.18;95%CI 0.87-1.62)。
- DMC组因脱位翻修风险更低(调整HR=0.09;95%CI 0.03-0.29)。
- DMC组因感染翻修风险更高(调整HR=3.20;95%CI 1.49-6.85)。
核心结论
- DMC组与MoP/CoP组总体翻修风险无差异。
- DMC可降低因脱位翻修的风险,但使用该轴承的THA更常因感染而翻修。
- 可能存在选择偏倚,倾向于将DMC植入更衰弱的患者,因为DMC组死亡率高于年龄和性别匹配的MoP/CoP组。
研究设计与样本
- 基于北欧关节置换登记协会(NARA)数据库的匹配人群研究,纳入1995年至2013年间使用DMC的THA。
- 采用倾向性评分匹配,按性别、年龄、部件固定方式和手术年份1:1匹配,共匹配2277例DMC患者与2277例MoP或CoP轴承患者。
- 采用竞争风险模型估计翻修累积发生率,以死亡为竞争风险,并进行竞争风险回归,终点为翻修或死亡。
- 证据等级:治疗性III级。
主要发现
- DMC组与倾向性评分匹配的MoP/CoP组总体翻修风险无差异(调整HR=1.18;95%CI 0.87-1.62)。
- DMC组因脱位翻修风险更低(调整HR=0.09;95%CI 0.03-0.29)。
- DMC组因感染翻修风险更高(调整HR=3.20;95%CI 1.49-6.85)。
- DMC组死亡率高于年龄和性别匹配的MoP/CoP组。
局限性
- 可能存在选择偏倚,倾向于将DMC植入更衰弱的患者,因为DMC组死亡率高于年龄和性别匹配的MoP/CoP组。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The dual mobility acetabular cup (DMC) was designed to reduce prosthetic instability and has gained popularity for both primary and revision total hip arthroplasty (THA). We compared the risk of revision of primary THA for primary osteoarthritis between patients treated with a DMC and those who received a metal-on-polyethylene (MoP) or ceramic-on-polyethylene (CoP) bearing. METHODS: A search of the Nordic Arthroplasty Register Association (NARA) database identified THAs performed with a DMC during 1995 to 2013. With use of propensity score matching, 2,277 of these patients were matched (1:1), with regard to sex, age, component fixation, and year of surgery, with patients with an MoP or CoP bearing. We estimated the cumulative incidence of revision taking death as a competing risk into consideration and performed competing risk regression with revision or death as end points. RESULTS: There was no difference in the overall risk of revision between the DMC group and the propensity-score-matched MoP/CoP group (adjusted hazard ratio [HR] = 1.18; 95% confidence interval [95% CI] = 0.87 to 1.62). Patients with a DMC bearing had a lower risk of revision due to dislocation (adjusted HR = 0.09; 95% CI = 0.03 to 0.29) but a higher risk of revision caused by infection (adjusted HR = 3.20; 95% CI = 1.49 to 6.85). CONCLUSIONS: There was no difference in overall risk of revision between the DMC and MoP/CoP groups. The DMCs protected against revision due to dislocation but THAs performed with this bearing were more commonly revised because of infection. There may have been a selection bias toward placing DMC implants in patients with greater frailty as the mortality rates were higher in the DMC group than in the age and sex-matched MoP/CoP group. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
引用
- Kreipke R, Rogmark C, Pedersen AB, et al. Dual Mobility Cups: Effect on Risk of Revision of Primary Total Hip Arthroplasty Due to Osteoarthritis: A Matched Population-Based Study Using the Nordic Arthroplasty Register Association Database. J Bone Joint Surg Am. 2019. PMID: 30653047. doi:10.2106/JBJS.17.00841
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。