文献速递关节外科创伤骨科

荧光原位杂交(FISH)用于福尔马林固定石蜡包埋手术组织假体周围关节感染的诊断

Fluorescence in Situ Hybridization (FISH) for the Diagnosis of Periprosthetic Joint Infection in Formalin-Fixed Paraffin-Embedded Surgical Tissues.
PubMed 文献 · J Bone Joint Surg Am · 2019-01-01

该研究回顾性分析88份关节假体周围膜,采用靶向多数细菌序列的探针进行FISH分析,并与MSIS临床分类、微生物培养及Morawietz和Krenn组织病理分类比较。FISH与临床分类比较灵敏度95%、特异度85.42%;与组织病理分类比较灵敏度95.12%、特异度87.23%,并可用种特异性探针区分铜绿假单胞菌和金黄色葡萄球菌。作者认为FISH诊断假体周围关节感染可行,可作为附加诊断标准。

要点

  • FISH与MSIS临床分类比较:灵敏度95%,特异度85.42%。
  • FISH与组织病理分类比较:灵敏度95.12%,特异度87.23%。
  • 种特异性FISH探针在所有培养阳性病例中检出铜绿假单胞菌和金黄色葡萄球菌。

核心结论

  • FISH诊断假体周围关节感染可行,可作为附加诊断标准。
  • FISH不仅能在假体周围膜中检测细菌,还能在种水平区分病原体。
  • FISH是检测假体周围膜中假体周围关节感染的快速可靠工具,尤其与临床和组织病理分类联合时。

研究设计与样本

  • 回顾性分析88份关节假体周围膜,按标准方案进行FISH分析。
  • 使用靶向多数细菌中存在的序列的探针。
  • 与MSIS指南的常规临床分类、微生物培养及Morawietz和Krenn组织病理分类比较。
  • 对若干培养阳性病例额外使用2种种特异性探针进行FISH分析。
  • 证据等级:诊断III级。

主要发现

  • FISH在临床分类评为阳性的40份假体周围膜中成功检出38份(95%)的细菌。
  • FISH与临床分类比较:灵敏度95%(95%CI 83.08%至99.39%),特异度85.42%(95%CI 72.24%至93.93%),阳性预测值84.44%(95%CI 70.55%至93.50%),阴性预测值95.35%(95%CI 84.19%至99.43%)。
  • FISH与组织病理分类比较:灵敏度95.12%(95%CI 83.47%至99.40%),特异度87.23%(95%CI 74.26%至95.17%),阳性预测值86.67%(95%CI 73.21%至94.95%),阴性预测值95.35%(95%CI 84.19%至99.43%)。
  • 种特异性FISH探针在所有经微生物培养对相应细菌呈阳性的病例中成功检出铜绿假单胞菌和金黄色葡萄球菌。

关键数值与推荐

  • MSIS推荐根据其指南诊断假体周围关节感染。
  • FISH与临床分类比较的灵敏度95%、特异度85.42%、阳性预测值84.44%、阴性预测值95.35%。
  • FISH与组织病理分类比较的灵敏度95.12%、特异度87.23%、阳性预测值86.67%、阴性预测值95.35%。

临床怎么用

  • 作者认为FISH诊断假体周围关节感染可行,可作为附加诊断标准。
  • 作者认为FISH是检测假体周围膜中假体周围关节感染的快速可靠工具,尤其与临床和组织病理分类联合时。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: As the number of arthroplasties performed increases, periprosthetic joint infection (PJI) represents a common and challenging problem. The Musculoskeletal Infection Society (MSIS) recommends diagnosing PJI according to its guidelines. The aim of the current study was to assess whether fluorescence in situ hybridization (FISH) analysis of formalin-fixed paraffin-embedded periprosthetic membranes can successfully improve the diagnosis of infection in patients with orthopaedic implants. METHODS: We retrospectively analyzed 88 periprosthetic membranes of joint prostheses using FISH analysis according to a standard protocol, with a probe targeting a sequence found in most bacteria. We compared the results with routine clinical classification according to the guidelines of the MSIS, microbiological culture, and histopathological classification according to Morawietz and Krenn. We additionally performed FISH analysis using 2 species-specific probes for several culture-positive cases. RESULTS: FISH successfully detected bacteria in 38 (95%) of 40 periprosthetic membranes that were rated positive by clinical classification. FISH results compared with clinical classification demonstrated a sensitivity of 95% (95% confidence interval [CI], 83.08% to 99.39%), a specificity of 85.42% (95% CI, 72.24% to 93.93%), a positive predictive value of 84.44% (95% CI, 70.55% to 93.50%), and a negative predictive value of 95.35% (95% CI, 84.19% to 99.43%). FISH results compared with histopathological classification demonstrated a sensitivity of 95.12% (95% CI, 83.47% to 99.40%), a specificity of 87.23% (95% CI, 74.26% to 95.17%), a positive predictive value of 86.67% (95% CI, 73.21% to 94.95%), and a negative predictive value of 95.35% (95% CI, 84.19% to 99.43%). We successfully detected Pseudomonas aeruginosa and Staphylococcus aureus with species-specific FISH probes in all cases that were positive for these respective bacteria by microbiological culture. CONCLUSIONS: FISH-based diagnosis of PJI is feasible and can be used as an additional diagnostic criterion. FISH not only can detect bacteria in periprosthetic membranes but can also differentiate pathogens at the species level. FISH represents a fast and reliable tool for detecting PJI in periprosthetic membranes, especially in combination with clinical and histopathological classification. LEVEL OF EVIDENCE: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.