文献速递关节外科

肥胖患者无影像导航髋臼假体放置的准确性与精确性

Accuracy and Precision of Acetabular Component Placement With Imageless Navigation in Obese Patients.
PubMed 文献 · J Arthroplasty · 2018-12-08

研究比较肥胖与非肥胖患者在全髋关节置换术中采用无影像导航放置髋臼假体的准确性与精确性,共纳入459例骨关节炎手术。肥胖组假体倾斜度精确性较差,但组间准确性无差异,83%假体位于目标范围;BMI连续增加与倾斜度超出目标范围风险升高相关(OR 1.06,P=0.001)。

要点

  • 肥胖与非肥胖患者无影像导航下髋臼假体倾斜度和前倾度准确性无显著差异。
  • 非肥胖患者倾斜度精确性优于肥胖患者,但差异可能无临床意义。
  • BMI每增加1单位,倾斜度超出目标范围的比值比为1.06(P=0.001)。

核心结论

  • 使用无影像导航时,肥胖患者倾斜度定向精确性较低,但观察到的差异可能无临床相关性。
  • 肥胖患者可实现准确的体表标志注册,无影像导航在肥胖与非肥胖患者中同样改善髋臼假体定位。

研究设计与样本

  • 回顾性审查单外科医生机构审查委员会批准数据库中的459例因骨关节炎行无影像导航全髋关节置换术的病例。
  • 采用Einzel-Bild-Roentgen Analyse在术后6周正位X线片上测定假体定向。
  • 比较肥胖(体重指数≥30 kg/m2)与非肥胖患者的平均定向误差(准确性)和精确性,并采用回归分析评估肥胖对假体位置的影响。

主要发现

  • 肥胖组与非肥胖组平均倾斜度分别为43.0°±3.5°(范围35.8°-57.8°)与41.9°±4.4°(范围33.0°-57.1°),差异为1.1°。
  • 肥胖组与非肥胖组平均前倾度分别为24.9°±6.3°(范围14.2°-44.3°)与23.8°±6.6°(范围7.0°-38.6°),差异为1.1°。
  • 非肥胖患者倾斜度精确性更好,组间倾斜度准确性及前倾度准确性或精确性均未检测到差异。
  • 83%的假体被放置在目标范围内。
  • 肥胖(二分类)与倾斜度、前倾度或两者同时超出目标范围之间无关系;作为连续变量,体重指数增加与倾斜度超出目标区域的比值升高相关(比值比1.06;P=0.001)。

临床怎么用

  • 作者认为,使用无影像导航时肥胖患者倾斜度精确性较低,但观察到的差异可能无临床相关性。
  • 作者认为,肥胖患者可实现准确的体表标志注册,无影像导航在肥胖与非肥胖患者中同样改善髋臼假体定位。

局限性

  • 证据等级为治疗性IV级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Obesity is a risk factor for acetabular component malposition when total hip arthroplasty is performed with manual techniques. The utility of imageless navigation in obese patients remains unknown. This study compared the accuracy and precision of imageless navigation for component orientation between obese and nonobese patients. METHODS: A total of 459 total hip arthroplasties performed for osteoarthritis using imageless navigation were reviewed from a single surgeon's institutional review board-approved database. Einzel-Bild-Roentgen Analyse determined component orientation on 6-week postoperative anteroposterior radiographs. Mean orientation error (accuracy) and precision were compared between obese (body mass index ≥ 30 kg/m2) and nonobese patients. Regression analysis evaluated the influence of obesity on component position. RESULTS: The difference in mean inclination and anteversion between obese and nonobese groups was 1.1° (43.0° ± 3.5°; range, 35.8°-57.8° vs 41.9° ± 4.4°; range, 33.0°-57.1° and 24.9° ± 6.3°; range, 14.2°-44.3° vs 23.8° ± 6.6°; range, 7.0°-38.6°, respectively). Inclination precision was better for nonobese patients. No difference in inclination accuracy or anteversion accuracy or precision was detected between groups. And 83% of components were placed within the target range. There was no relationship between obesity (dichotomized) and component placement outside the target ranges for inclination, anteversion, or both. As a continuous variable, increased body mass index correlated with higher odds of inclination outside the target zone (odds ratio, 1.06; P = .001). CONCLUSION: Using imageless navigation, inclination orientation was less precise for obese patients, but the observed difference is likely not clinically relevant. Accurate superficial registration of landmarks in obese patients is achievable, and the use of imageless navigation similarly improves acetabular component positioning in obese and nonobese patients. LEVEL OF EVIDENCE: Therapeutic Level IV.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Buller LT, McLawhorn AS, Romero JA, et al. Accuracy and Precision of Acetabular Component Placement With Imageless Navigation in Obese Patients. J Arthroplasty. 2018. PMID: 30616976. doi:10.1016/j.arth.2018.12.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。