全膝关节置换术中股骨远端固定6°外翻截骨:788例连续病例的影像学回顾
回顾性分析788例连续全膝关节置换术,股骨远端截骨固定为6°外翻,术前及术后6周测量髋-踝X线机械轴。术后全体患者机械轴为0.0°±2.3°(范围-7.0°至8.0°),86.5%内翻患者、86.1%中立患者和82.5%外翻患者术后获得中立机械轴。作者认为在缺乏复杂术前规划工具时,该简单技术可能比测量胫股角更可靠。
要点
- 788例连续全膝关节置换术均采用股骨远端固定6°外翻截骨。
- 术后全体患者机械轴为0.0°±2.3°(范围-7.0°至8.0°)。
- 术后中立机械轴(-3°<MA<3°)在术前内翻、中立和外翻组分别占86.5%、86.1%和82.5%。
核心结论
- 标准股骨远端6°截骨使86%的患者获得中立机械轴。
- 作者认为,在缺乏复杂术前规划工具时,这种简单技术可能比测量胫股角提供更可靠的手术技术。
研究设计与样本
- 回顾性研究,纳入788例连续全膝关节置换术,股骨远端截骨设定为6°外翻。
- 术前和术后6周在髋-踝X线片上测量机械轴,并按术前畸形分组(MA<-3°、-3°<MA<3°、3°<MA)。
主要发现
- 术后全体患者机械轴为0.0°±2.3°(范围-7.0°至8.0°)。
- 按术前对线分组:内翻(MA<-3°)548例,中立(-3°<MA<3°)137例,外翻(3°<MA)103例。
- 术后中立对线(-3°<MA<3°)在内翻组为86.5%,中立组为86.1%,外翻组为82.5%。
关键数值与推荐
- 股骨远端截骨固定为6°外翻。
- 中立机械轴定义为-3°<MA<3°。
- 术后全体患者机械轴为0.0°±2.3°(范围-7.0°至8.0°)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In place of the mechanical axis (MA), the use of the variable tibiofemoral angle is frequently used to plan measured resection bony cuts during total knee arthroplasty (TKA). This angle, coupled with operator-dependent variability of intramedullary distal femoral cutting guides, has the potential for catastrophic outcomes. Therefore, a simpler, fixed femoral cut of 6° valgus may be more appropriate when direct measurement of the MA is not possible. METHODS: This was a retrospective study of 788 consecutive TKAs, in which the distal femoral cut was set to 6° valgus. The preoperative and 6-week postoperative MA were measured on hip-to-ankle radiographs. Data were evaluated as a group as well as grouped by preoperative deformity (MA < -3°, -3° < MA < 3°, 3° < MA). RESULTS: Following TKA, MA alignment for all patients was 0.0° ± 2.3° (range, -7.0° to 8.0°). When grouped by pre-TKA alignment, 548 patients were considered varus (MA < -3°), 137 were neutral (-3° < MA < 3°), and 103 patients were valgus (3° < MA). When evaluating the post-TKA alignment achieved in the 3 groups, neutral alignment (-3° < MA < 3°) was established in 86.5% of varus patients, 86.1% of neutral patients, and 82.5% of valgus patients. CONCLUSION: A standard distal femoral cut of 6° resulted in a neutral MA in 86% of patients. While no single technique will be correct for all deformities, in the absence of sophisticated preoperative planning aids, this simple technique could provide a more reliable surgical technique than the measured tibiofemoral angle.
引用
- Andrews SN, Beeler DM, Parke EA, et al. Fixed Distal Femoral Cut of 6° Valgus in Total Knee Arthroplasty: A Radiographic Review of 788 Consecutive Cases. J Arthroplasty. 2018. PMID: 30616977. doi:10.1016/j.arth.2018.12.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。