内侧球窝型全膝关节置换术:五年临床结果
本研究回顾性分析了首批100例连续接受SAIPH内侧球窝型全膝关节置换术(TKA)患者的五年随访数据,评估临床与影像学结局。结果显示所有患者报告结局指标(PROMs)显著改善且满意度高,平均活动度为0°至124°屈曲,主要并发症发生率为7%,无植入物相关影像学并发症。作者认为该系统的安全性和有效性支持其更广泛应用。
要点
- SAIPH内侧球窝型TKA术后五年所有PROMs显著改善,患者满意度高。
- 末次随访平均活动度为0°(完全伸直)至124°屈曲。
- 主要并发症7例(7%),包括1例感染、2例深静脉血栓、1例脑血管事件、2例僵硬需麻醉下手法松解。
核心结论
- SAIPH内侧球窝型TKA术后五年临床和影像学结果满意,并发症率和翻修率与既往TKA报道一致,作者认为该系统的安全性和有效性支持其更广泛应用。
研究设计与样本
- 回顾性综述,纳入由资深作者实施的首批100例连续SAIPH TKA患者,随访五年,数据包括人口学、临床发现、术中韧带松解率、PROMs、影像学评估、并发症和全因翻修,翻修数据与国家登记系统交叉核对。
主要发现
- 共纳入92例患者100例TKA,3例患者(3例TKA)死亡,另2例TKA翻修,剩余95例TKA中81例(85%)获得五年随访数据(涉及87例患者)。
- 所有PROMs显著改善且满意度高,末次随访平均活动度为0°(完全伸直)至124°屈曲。
- 主要并发症7例(7%):1例感染、2例深静脉血栓、1例脑血管事件、2例僵硬需麻醉下手法松解。
- 2例患者因外翻膝需行外侧支持带松解以优化髌骨轨迹,所有患者均未行额外韧带松解。
- 影像学分析未显示植入物相关并发症证据。
临床怎么用
- 原文结论指出该结果支持SAIPH膝关节TKA系统的更广泛应用(作者结论)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Between 15% and 20% of patients remain dissatisfied following total knee arthroplasty (TKA). The SAIPH knee system (MatOrtho, Surrey, United Kingdom) is a medial ball and socket TKA that has been designed to replicate native knee kinematics in order to maximize the range of movement, stability, and function. This system is being progressively introduced in a stepwise fashion, with this study reporting the mid-term clinical and radiological outcomes. PATIENTS AND METHODS: A retrospective review was undertaken of the first 100 consecutive patients with five-year follow-up following SAIPH TKA performed by the senior authors. The data that were collected included the demographics of the patients, clinical findings, the rate of intraoperative ligamentous release, patient-reported outcome measures (PROMS), radiological assessment, complications, and all-cause revision. Revision data were cross-checked with a national registry. RESULTS: A total of 100 TKAs in 92 patients were included. Three patients died (three TKAs) and a further two TKAs were revised. Of the remaining 95 TKAs, five-year follow-up data were available for 81 TKAs (85%) in 87 patients. There were significant improvements in all PROMs and high satisfaction. The mean ROM at final follow-up was from 0° (full extension) to 124° flexion. There were seven major complications (7%): one infection, two deep vein thromboses, one cerebrovascular event, and two patients with stiffness requiring a manipulation under anaesthesia. Two patients required a lateral retinacular release to optimize patellar tracking in valgus knees; no additional ligament releases were performed in any patient. Radiological analysis demonstrated no evidence of implant-related complications. CONCLUSION: These results demonstrate satisfactory clinical and radiological outcomes at five years following a medial ball and socket TKA. The complication and revision rates are consistent with those previously reported for patients undergoing TKA. These results demonstrate the safety and efficacy of the SAIPH Knee TKA system and support its wider use.
引用
- Katchky AM, Jones CW, Walter WL, et al. Medial ball and socket total knee arthroplasty: five-year clinical results. Bone Joint J. 2019. PMID: 30648493. doi:10.1302/0301-620X.101B1.BJJ-2018-0434.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。