矿化胶原改性聚甲基丙烯酸甲酯骨水泥治疗骨质疏松性椎体压缩骨折的1年随访
该回顾性对比研究将105例骨质疏松性椎体压缩骨折(OVCF)患者按经皮椎体后凸成形术(PKP)治疗分为MC-PMMA组与PMMA组,比较术后及1年随访的临床与影像学指标。结果显示MC-PMMA组在1年随访时疼痛、功能障碍及后凸角改善更优,骨水泥渗漏率与再骨折率更低,伤椎CT值更高。作者认为MC改性PMMA未改变PMMA的有益特性,具有更好的生物相容性。
要点
- MC-PMMA组1年随访时VAS、ODI及Cobb角与PMMA组差异有统计学意义。
- MC-PMMA组骨水泥渗漏率与再骨折率均低于PMMA组。
- MC-PMMA组1年随访时伤椎CT值明显高于PMMA组。
核心结论
- MC改性PMMA未改变PMMA的有益特性,该新型骨水泥具有更好的生物相容性,可在椎体内形成稳定结构,并通过减轻疼痛和减少再手术改善患者预后。
研究设计与样本
- 回顾性对比研究,纳入2016年7月至2017年7月间105例OVCF患者,按PKP治疗随机分为MC-PMMA组与PMMA组。
主要发现
- 两组临床操作无差异。
- 1年随访时两组VAS评分、ODI评分及Cobb角差异有统计学意义。
- 椎体高度在每组术前与术后3天差异有统计学意义,1年后两组间差异有统计学意义。
- MC-PMMA组再骨折率与骨水泥渗漏率低于PMMA组。
- 1年随访时MC-PMMA组伤椎CT值明显高于PMMA组。
临床怎么用
- 作者认为MC改性PMMA具有更好的生物相容性,可在椎体内形成稳定结构,并通过减轻疼痛和减少再手术改善患者预后。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Retrospective comparative study. OBJECTIVE: This study aimed to compare the clinical effects and imaging features of polymethyl methacrylate (PMMA) bone cement with and without mineralized collagen (MC) in percutaneous kyphoplasty (PKP) for osteoporotic vertebral compression fractures (OVCFs). SUMMARY OF BACKGROUND DATA: PKP with PMMA is widely performed for OVCF. However, numerous complications have also been reported about the PMMA bone cement. Moreover, PMMA bone cement with and without MC have not been compared with respect to their postoperative efficacy and long-term follow-up. METHODS: From July 2016 to July 2017, 105 OVCF patients were randomly divided into two groups based on their PKP treatment: MC-PMMA group and PMMA group. Clinical operation, cement leakage, Oswestry Disability Index, visual analog scale, height of the fractured vertebrae, Cobb angle, refracture of the adjacent vertebra, recompression, and computed tomography values of the injured vertebra were compared between the two groups postoperatively and after 1-year follow-up. RESULTS: Clinical operation showed no differences between the two groups. Visual analog scale scores, Oswestry Disability Index scores, and Cobb angles showed statistically significant differences between the two groups after 1-year follow-up. The height of the vertebral body showed significant difference at 3 days postoperatively and preoperatively in each group and significant difference after 1 year between the two groups. The rate of refracture and leakage of the MC-PMMA group was lower than that of the PMMA group. The computed tomography value of the MC-PMMA group was obviously higher than that of the PMMA group after 1-year follow-up. CONCLUSION: MC-modified PMMA did not change the beneficial properties of PMMA. This new bone cement has better biocompatibility, can form a stable structure in the vertebral body, and improve the prognosis of patients by reducing pain and reoperation. LEVEL OF EVIDENCE: 3.
引用
- Zhu J, Zhang K, Luo K, et al. Mineralized Collagen Modified Polymethyl Methacrylate Bone Cement for Osteoporotic Compression Vertebral Fracture at 1-Year Follow-up. Spine (Phila Pa 1976). 2019. PMID: 30601358. doi:10.1097/BRS.0000000000002971
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。