文献速递关节外科

全膝关节置换假体设计与聚乙烯类型对感染翻修风险的影响:澳大利亚骨科协会国家关节置换登记系统336,997例假体分析

The Effect of Prosthetic Design and Polyethylene Type on the Risk of Revision for Infection in Total Knee Replacement: An Analysis of 336,997 Prostheses from the Australian Orthopaedic Association National Joint Replacement Registry.
PubMed 文献 · J Bone Joint Surg Am · 2018-01-01

本研究基于澳大利亚骨科协会国家关节置换登记系统1999年9月至2015年12月的数据,分析336,997例因骨关节炎行初次全膝关节置换的假体,比较4种假体设计(微稳定型/后稳定型)与聚乙烯类型(交联/非交联)组合对感染翻修风险的长期影响。结果显示,以微稳定型+交联聚乙烯为参照,微稳定型+非交联聚乙烯、后稳定型+交联聚乙烯、后稳定型+非交联聚乙烯的感染翻修风险分别高25%、89%、102%;后稳定型+非交联聚乙烯较微稳定型+非交联聚乙烯高61%;后稳定型+非交联聚乙烯与后稳定型+交联聚乙烯无显著差异。

要点

  • 微稳定型+非交联聚乙烯较微稳定型+交联聚乙烯的感染翻修风险高25%(HR=1.25,95%CI 1.07-1.45,p=0.003)。
  • 后稳定型+交联聚乙烯较微稳定型+交联聚乙烯的感染翻修风险高89%(HR=1.89,95%CI 1.52-2.35,p<0.001)。
  • 后稳定型+非交联聚乙烯较微稳定型+交联聚乙烯的感染翻修风险高102%(HR=2.02,95%CI 1.72-2.37,p<0.001)。

核心结论

  • 与微稳定型+交联聚乙烯假体相比,微稳定型+非交联聚乙烯假体及后稳定型假体(无论聚乙烯类型)的长期假体周围感染翻修风险更高。

研究设计与样本

  • 基于澳大利亚骨科协会国家关节置换登记系统的数据分析,纳入1999年9月至2015年12月因骨关节炎行初次全膝关节置换的4个患者队列,按假体设计与聚乙烯类型定义,共336,997例假体。

主要发现

  • 共纳入336,997例初次全膝关节置换假体,其中1,651例(0.49%)因假体周围感染行翻修。
  • 以微稳定型+交联聚乙烯为参照(校正年龄、性别和抗生素骨水泥使用),微稳定型+非交联聚乙烯的感染翻修风险高25%(HR=1.25,95%CI 1.07-1.45,p=0.003)。
  • 以微稳定型+交联聚乙烯为参照,后稳定型+交联聚乙烯的感染翻修风险高89%(HR=1.89,95%CI 1.52-2.35,p<0.001)。
  • 以微稳定型+交联聚乙烯为参照,后稳定型+非交联聚乙烯的感染翻修风险高102%(HR=2.02,95%CI 1.72-2.37,p<0.001)。
  • 后稳定型+非交联聚乙烯较微稳定型+非交联聚乙烯的感染翻修风险高61%(HR=1.61,95%CI 1.43-1.83,p<0.001)。

关键数值与推荐

  • 翻修定义为因外科医生报告的感染而行翻修手术,≤6个月的翻修被删失以减少混杂偏倚。
  • 风险比(HR)校正了年龄、性别和抗生素骨水泥使用。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Periprosthetic infection following total knee replacement remains alarmingly frequent, is devastating for patients, and is an increasingly substantial public health burden. While both the prosthetic design elements and type of polyethylene used in total knee replacement can independently affect survivorship of the prosthesis, their influence on the risk of revision for infection is unknown. Therefore, we examined the effects of total knee prosthetic design and type of polyethylene bearing on the long-term revision risk for nonacute infection following total knee replacement by comparing 4 different cohorts: patients who had minimally stabilized total knee prostheses with crosslinked polyethylene (XLPE) bearing surfaces, minimally stabilized total knee prostheses with noncrosslinked polyethylene (NXLPE), posterior stabilized total knee prostheses with XLPE, and posterior stabilized total knee prostheses with NXLPE. METHODS: National registry data on revision procedures for surgeon-reported infection following primary total knee replacement for osteoarthritis from September 1999 through December 2015 were obtained for 4 patient cohorts. The cohorts were defined by the total knee prosthetic design and polyethylene type used. Revisions at ≤6 months were censored to reduce confounding bias. Hazard ratios (HRs) were adjusted for age, sex, and antibiotic cement usage. RESULTS: A total of 336,997 primary total knee prostheses were included, 1,651 (0.49%) of which underwent revision for periprosthetic infection. Compared with minimally stabilized total knee prostheses that had XLPE bearing surfaces, the revision risk for infection, adjusted for age, sex, and antibiotic cement usage, was 25% higher for minimally stabilized total knee prostheses with NXLPE bearing surfaces (HR = 1.25 [95% confidence interval (CI), 1.07 to 1.45]; p = 0.003), 89% higher for posterior stabilized total knee prostheses with XLPE (HR = 1.89 [95% CI, 1.52 to 2.35]; p < 0.001), and 102% higher for posterior stabilized total knee prostheses with NXLPE (HR = 2.02 [95% CI, 1.72 to 2.37]; p < 0.001). Posterior stabilized total knee prostheses with NXLPE had a 61% higher risk of infection compared with minimally stabilized total knee prostheses with NXLPE (HR = 1.61 [95% CI, 1.43 to 1.83]; p < 0.001). The revision risk for infection for posterior stabilized total knee prostheses with NXLPE was the same as that for posterior stabilized total knee prostheses with XLPE (HR = 1.08 [95% CI, 0.88 to 1.32]; p = 0.481). CONCLUSIONS: Minimally stabilized total knee prostheses with NXLPE bearing surfaces and posterior stabilized total knee prostheses, irrespective of bearing type, had a greater long-term revision risk for periprosthetic infection when compared with the revision risk for minimally stabilized total knee prostheses with XLPE bearing surfaces. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of Levels of Evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Vertullo CJ, de Steiger RN, Lewis PL, et al. The Effect of Prosthetic Design and Polyethylene Type on the Risk of Revision for Infection in Total Knee Replacement: An Analysis of 336,997 Prostheses from the Australian Orthopaedic Association National Joint Replacement Registry. J Bone Joint Surg Am. 2018. PMID: 30516626. doi:10.2106/JBJS.17.01639

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。