双十字韧带保留型全膝关节置换术中的爬楼梯与高屈膝活动:体内运动学与关节接触分析
研究纳入29例单侧双十字韧带保留型全膝关节置换术(BCR TKA)患者,采用CT与双荧光透视成像系统评估深蹲、上台阶和坐站转换时双膝的关节接触位置。结果显示BCR TKA外侧髁接触点较对侧非手术膝更偏前,股骨外旋减少,仅约半数患者呈现内侧枢轴模式,提示高强度屈膝活动下体内胫股运动学未完全恢复。
要点
- BCR TKA外侧髁接触点在坐站转换、深蹲和上台阶时均较对侧非手术膝更偏前。
- BCR TKA在坐站转换、深蹲和上台阶时股骨外旋均较对侧非手术膝减少。
- 仅59%、56%和48%的BCR TKA膝在上台阶、坐站转换和深蹲时呈现内侧枢轴模式。
核心结论
- 当代BCR TKA设计在约半数患者中表现为不对称股骨后滚、内侧平移及外侧枢轴,提示高强度屈膝活动下体内胫股运动学参数未完全恢复。
研究设计与样本
- 研究纳入29例单侧BCR TKA患者,采用经过验证的CT与双荧光透视成像系统组合,评估深蹲、上台阶和坐站转换时双膝的关节接触位置。
主要发现
- 坐站转换时BCR TKA外侧髁接触位移为-4.9±3.1 mm,对侧非手术膝为-9.7±4.6 mm,BCR TKA更偏前(P<.05)。
- 单次深蹲时BCR TKA外侧髁接触位移为-5.7±3.2 mm,对侧非手术膝为-10.0±4.5 mm,BCR TKA更偏前(P<.05)。
- 上台阶时BCR TKA外侧髁接触位移为-4.8±3.6 mm,对侧非手术膝为-9.1±3.9 mm,BCR TKA更偏前(P<.05)。
- 坐站转换时BCR TKA股骨外旋为2.1±4.8°,对侧非手术膝为7.7±5.4°,BCR TKA减少(P<.05);单次深蹲时分别为1.8±4.8°与7.0±7.1°(P<.05);上台阶时分别为0.1±4.1°与6.2±4.9°(P<.05)。
- BCR TKA膝呈现内侧枢轴模式的比例分别为上台阶59%、坐站转换56%、单次深蹲48%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Bi-cruciate retaining (BCR) total knee arthroplasty (TKA) preserves both anterior and posterior cruciate ligaments with the potential to restore normal posterior femoral rollback and joint kinematics. However, there is limited information regarding articular contact behavior in the contemporary BCR TKA design during high knee flexion activities. This study aimed to investigate the articular knee contact performance in unilateral BCR TKA patients during strenuous flexion activities. METHODS: Twenty-nine unilateral BCR TKA patients were evaluated for both knees during single deep lunges, step-ups, and sit-to-stand (STS) using a validated combined computer tomography and dual fluoroscopic imaging system. Medial and lateral condylar contact positions were quantified during weight-bearing flexion. RESULTS: Contact excursions of the lateral condyle in BCR TKAs were significantly more anteriorly located than the contralateral non-operated knees during STS (-4.9 ± 3.1 vs -9.7 ± 4.6 mm, P < .05), single deep lunge (-5.7 ± 3.2 vs -10.0 ± 4.5 mm, P < .05), and step-ups (-4.8 ± 3.6 vs -9.1 ± 3.9 mm, P < .05). Contact points of BCR TKAs indicated reduced femoral external rotation during STS (2.1 ± 4.8° vs 7.7 ± 5.4°, P < .05), single deep lunges (1.8 ± 4.8° vs 7.0 ± 7.1°, P < .05), and step-ups (0.1 ± 4.1° vs 6.2 ± 4.9°, P < .05). Medial pivoting patterns were observed in only 59%, 56%, and 48% of the BCR TKA knees for step-ups, STS, and single deep lunge, respectively. CONCLUSION: The contemporary BCR TKA design demonstrated asymmetric femoral rollback, medial translation, as well as lateral pivoting in about half of the patient cohort, suggesting that in vivo tibiofemoral kinematic parameters were not fully restored in BCR patients during strenuous flexion activities.
引用
- Arauz P, Klemt C, Limmahakhun S, et al. Stair Climbing and High Knee Flexion Activities in Bi-Cruciate Retaining Total Knee Arthroplasty: In Vivo Kinematics and Articular Contact Analysis. J Arthroplasty. 2018. PMID: 30514641. doi:10.1016/j.arth.2018.11.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。