文献速递关节外科

双十字稳定型全膝关节置换术中髌股关节压缩力对患者报告结局的影响

The influence of compressive forces across the patellofemoral joint on patient-reported outcome after bi-cruciate stabilized total knee arthroplasty.
PubMed 文献 · Bone Joint J · 2018-01-01

前瞻性研究纳入42例(42膝)内翻型骨关节炎行双十字稳定型全膝关节置换术患者,术中测量髌股关节压缩力,分析其与术后2年患者报告结局的关系。140°屈曲位压缩力与患者满意度(R²=0.458;β=-0.706;β=-0.636;β=-0.688;作者认为降低60°和140°屈曲位髌股压缩力可能改善患者报告结局,但对膝前痛无影响。

要点

  • 术后无患者出现膝前痛,作者认为降低压缩力可能改善患者报告结局但对膝前痛无影响。

核心结论

  • 患者满意度、FJS-12和髌骨评分受60°和140°屈曲位髌股压缩力影响。
  • 作者认为全膝关节置换术中降低60°和140°屈曲位髌股压缩力可能改善患者报告结局,但对膝前痛无影响。

研究设计与样本

  • 前瞻性研究纳入42例(42膝)内翻型骨关节炎患者,均行双十字稳定型全膝关节置换术,且计划对线经3D CT确认。
  • 42例中36例为女性、6例为男性,平均年龄72.3岁(61至87),平均体重指数24.4 kg/m²(18.2至34.3)。
  • 植入股骨和胫骨假体后,使用与髌骨假体同形状制造的载荷传感器(Kyowa Electronic Instruments Co., Ltd., Tokyo, Japan)在屈曲10°、30°、60°、90°、120°和140°位测量髌股关节压缩力。
  • 采用多元回归分析探讨术中髌股压缩力与植入后2年患者报告结局的关系。

主要发现

  • 术后无患者出现膝前痛。

临床怎么用

  • 作者认为全膝关节置换术中降低60°和140°屈曲位髌股压缩力可能改善患者报告结局,但对膝前痛无影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Patellofemoral problems are a common complication of total knee arthroplasty. A high compressive force across the patellofemoral joint may affect patient-reported outcome. However, the relationship between patient-reported outcome and the intraoperative patellofemoral contact force has not been investigated. The purpose of this study was to determine whether or not a high intraoperative patellofemoral compressive force affects patient-reported outcome. PATIENTS AND METHODS: This prospective study included 42 patients (42 knees) with varus-type osteoarthritis who underwent a bi-cruciate stabilized total knee arthroplasty and in whom the planned alignment was confirmed on 3D CT. Of the 42 patients, 36 were women and six were men. Their mean age was 72.3 years (61 to 87) and their mean body mass index (BMI) was 24.4 kg/m 2 (18.2 to 34.3). After implantation of the femoral and tibial components, the compressive force across the patellofemoral joint was measured at 10°, 30°, 60°, 90°, 120°, and 140° of flexion using a load cell (Kyowa Electronic Instruments Co., Ltd., Tokyo, Japan) manufactured in the same shape as the patellar implant. Multiple regression analyses were conducted to investigate the relationship between intraoperative patellofemoral compressive force and patient-reported outcome two years after implantation. RESULTS: No patient had anterior knee pain after total knee arthroplasty. The compressive force across the patellofemoral joint at 140°of flexion was negatively correlated with patient satisfaction (R 2 = 0.458; β = -0.706; p = 0. 041) and Forgotten Joint Score-12 (FJS-12; R 2 = .378; β = -0.636; p = 0. 036). The compressive force across the patellofemoral joint at 60° of flexion was negatively correlated with the patella score (R 2 = 0.417; β = -0.688; p = 0. 046). CONCLUSION: Patient satisfaction, FJS-12, and patella score were affected by the patellofemoral compressive force at 60° and 140° of flexion. Reduction of the patellofemoral compressive forces at 60° and 140° of flexion angle during total knee arthroplasty may improve patient-reported outcome, but has no effect on anterior knee pain.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Kaneko T, Kono N, Mochizuki Y, et al. The influence of compressive forces across the patellofemoral joint on patient-reported outcome after bi-cruciate stabilized total knee arthroplasty. Bone Joint J. 2018. PMID: 30499324. doi:10.1302/0301-620X.100B12.BJJ-2018-0693.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。