文献速递关节外科

低接触应力旋转平台全膝关节置换术无骨水泥胫骨组件十七至二十年随访

Seventeen to Twenty Years of Follow-Up of the Low Contact Stress Rotating-Platform Total Knee Arthroplasty With a Cementless Tibia in All Cases.
PubMed 文献 · J Arthroplasty · 2018-11-23

前瞻性分析500例低接触应力旋转平台活动平台全膝关节置换术,胫骨组件均无骨水泥固定,最短随访17年。以任何原因翻修为终点,累积生存率为97.4%,患者报告功能评分可接受。

要点

  • 500例全膝关节置换术在467例患者中施行,平均随访18.1年(范围17.0-21.8年),141膝(28.2%)存活并可复查。
  • 以任何原因翻修为终点,累积生存率为97.4%;13膝需翻修。
  • 平均美国膝关节协会评分:评估评分83分,功能评分48分;平均牛津膝关节评分32.1分,平均Bartlett髌骨评分21.6分。

核心结论

  • 该系列显示,活动平台全膝关节置换术使用无骨水泥胫骨托在最短17年随访时具有优异的生存率和可接受的患者报告功能结局评分。

研究设计与样本

  • 前瞻性分析500例低接触应力旋转平台活动平台全膝关节置换术,胫骨组件均无骨水泥固定,最短随访17年。
  • 500例初次全膝关节置换术在467例患者中施行,平均随访18.1年(范围17.0-21.8年),141膝(28.2%)存活并可复查。

主要发现

  • 以任何原因翻修为终点,累积生存率为97.4%。
  • 13膝需翻修:3膝深部感染,3膝仅更换衬垫处理脱位,3膝胫骨托下沉,2膝二期髌骨表面置换,1膝无菌性松动,1膝疑似无菌性松动但术中发现固定良好。
  • 平均美国膝关节协会评分:评估评分83分,功能评分48分;平均牛津膝关节评分32.1分,平均Bartlett髌骨评分21.6分。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Total knee arthroplasty designs can be categorized by bearing design and fixation method. The mobile-bearing concept was developed with the aim of increasing longevity and improving function by reduced polyethylene wear and closer replication of physiological knee motion. Cementless fixation has the goal of achieving a long-lasting "biological" fixation between prosthesis and bone. METHODS: Prospective analysis of the survivorship and patient-reported functional outcomes of a series of 500 low contact stress rotating-platform mobile-bearing total knee arthroplasties with a cementless tibial component with a minimum 17-year follow-up. RESULTS: Five hundred primary total knee arthroplasties were conducted in 467 patients. Mean follow-up was 18.1 (17.0-21.8) years and 141 (28.2%) knees were alive and available for review. Using revision for any cause as the end point, cumulative survivorship was 97.4%. Thirteen knees required revision: 3 for deep infection, 3 bearing only revisions for spinout, 3 for tibial tray subsidence, 2 secondary patella resurfacings, 1 aseptic loosening, and 1 for suspected aseptic loosening that was found to be well fixed. Mean American Knee Society Scores were 83 (evaluation) and 48 (function), Mean Oxford Knee Score was 32.1, and the mean Bartlett Patellar Score was 21.6. CONCLUSION: This series demonstrates excellent survivorship and acceptable patient-reported functional outcome scores of a mobile-bearing total knee arthroplasty with a cementless tibial tray at minimum 17-year follow-up.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. McMahon SE, Doran E, O'Brien S, et al. Seventeen to Twenty Years of Follow-Up of the Low Contact Stress Rotating-Platform Total Knee Arthroplasty With a Cementless Tibia in All Cases. J Arthroplasty. 2018. PMID: 30553560. doi:10.1016/j.arth.2018.11.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。