患者自报关节置换术前后活动水平既不准确也不可重复
本研究纳入66例全髋或全膝关节置换术患者,术前及术后6-8周佩戴FitBit Zip加速度计并每日自报步行距离。患者自报误差均值术前69%(SD 58%)、术后93%(SD 86%),均超过50%误差界限(术前p=0.002,术后p<0.001),且误差随时间增大(p=0.001)。作者认为临床医生解读患者自报活动水平时应谨慎。
要点
- 患者自报步行距离误差均值术前69%、术后93%,均超过50%误差界限。
- 自报误差随时间增大(p=0.001)。
- 临床医生解读患者自报活动水平时应谨慎。
核心结论
- 患者对每日步行距离的估计与加速度计记录的距离存在实质性差异,临床医生解读患者自报活动水平时应谨慎。
研究设计与样本
- 前瞻性诊断研究,招募全髋或全膝关节置换术患者,16个月内筛查121例、纳入66例(55%)。
- 纳入与筛查患者在平均年龄(p=0.68)、髋膝比例(p=0.95)和性别(p=0.16)上无差异。
- 患者佩戴FitBit Zip加速度计1周且对测量值盲态,每日自报以英里计的感知步行距离。
- 数据于术前及术后6至8周收集,以加速度计距离归一化后行Wilcoxon单侧符号秩检验,主要终点为患者平均误差与50%误差界限的比较。
主要发现
- 患者自报步行距离不准确,自报误差均值术前超过50%(p=0.002)、术后超过50%(p<0.001)。
- 误差幅度均值术前69%(SD 58%)、术后93%(SD 86%),且随时间增大(p=0.001)。
临床怎么用
- 作者认为,临床医生解读患者自报活动水平时应谨慎。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Patients often are asked to report walking distances before joint arthroplasty and when discussing their results after surgery, but little evidence demonstrates whether patient responses accurately represent their activity. QUESTIONS/PURPOSES: Are patients accurate in reporting distance walked, when compared with distance measured by an accelerometer, within a 50% margin of error? METHODS: Patients undergoing THA or TKA were recruited over a 16-month period. One hundred twenty-one patients were screened and 66 patients (55%) were enrolled. There were no differences in mean age (p = 0.68), proportion of hips versus knees (p = 0.95), or sex (p = 0.16) between screened and enrolled patients. Each patient wore a FitBit Zip accelerometer for 1 week and was blinded to its measurements. The patients reported their perceived walking distance in miles daily. Data were collected preoperatively and 6 to 8 weeks postoperatively. Responses were normalized against the accelerometer distances and Wilcoxon one-tailed signed-rank testing was performed to compare the mean patient error with a 50% margin of error, our primary endpoint. RESULTS: We found that patients' self-reported walking distances were not accurate. The mean error of reporting was > 50% both preoperatively (p = 0.002) and postoperatively (p < 0.001). The mean magnitude of error was 69% (SD 58%) preoperatively and 93% (SD 86%) postoperatively and increased with time (p = 0.001). CONCLUSIONS: Patients' estimates of daily walking distances differed substantially from those patients' walking distances as recorded by an accelerometer, the accuracy of which has been validated in treadmill tests. Providers should exercise caution when interpreting patient-reported activity levels. LEVEL OF EVIDENCE: Level III, diagnostic study.
引用
- Vaughn NH, Dunklebarger MF, Mason MW, et al. Individual Patient-reported Activity Levels Before and After Joint Arthroplasty Are Neither Accurate nor Reproducible. Clin Orthop Relat Res. 2019. PMID: 30543533. doi:10.1097/CORR.0000000000000591
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。