有限序列MRI对早发性脊柱侧凸患者神经轴异常的检出率达100%,同时将MRI时间缩短68%
本研究为诊断准确性研究,回顾性纳入2017年2月至12月连续50例接受颈椎、胸椎和腰椎MRI的早发性脊柱侧凸(EOS)患者,比较仅阅读矢状位T1和矢状位T2两个序列与基于全部标准序列的既往放射科报告对神经轴异常的检出情况。全MRI检出10例(20%)神经轴异常,矢状位T1+矢状位T2组合全部检出,灵敏度100%;标准MRI耗时66±20分钟、麻醉90±22分钟,有限序列耗时21±7分钟(P<0.0001),MRI时间减少68%。
要点
- 50例EOS患者中全MRI检出10例(20%)神经轴异常。
- 矢状位T1+矢状位T2两序列检出全部神经轴异常,灵敏度100%。
- 有限序列MRI耗时21±7分钟,标准MRI耗时66±20分钟(P<0.0001),时间减少68%。
核心结论
- 对EOS患者采用矢状位T1和T2有限序列MRI检测神经轴异常灵敏度为100%,可使MRI时长减少68%并显著减少麻醉时间。
研究设计与样本
- 诊断准确性研究,回顾性连续纳入2017年2月至12月接受颈、胸、腰段脊柱MRI的EOS患者50例。
- 由一名儿童神经放射学主治医师在另一时间仅阅读矢状位T1和矢状位T2两个序列,并与基于全部标准MRI序列的既往放射科报告比较。
主要发现
- 50例中10例(20%)经全MRI检出神经轴异常,全部在矢状位T1+矢状位T2组合上检出。
- 标准MRI时长66±20分钟,患者麻醉时长90±22分钟。
- 矢状位T1+矢状位T2序列时长21±7分钟(P<0.0001)。
关键数值与推荐
- 有限序列MRI(矢状位T1、矢状位T2)检测神经轴异常灵敏度100%。
- MRI时长减少68%,麻醉时间显著减少(P<0.0001)。
局限性
- 证据等级为3级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Diagnostic accuracy. OBJECTIVE: The purpose of this study was to determine if neural axis abnormalities in early onset scoliosis (EOS) patients can be reliably detected with limited magnetic resonance imaging (MRI) sequences (sagittal T1, sagittal T2). SUMMARY OF BACKGROUND DATA: MRIs are often performed in EOS patients as studies have shown there are neural axis abnormalities in up to 40% of this population. MRIs are expensive, lengthy, and often require general anesthesia. In young children prolonged or repeated exposure to general anesthesia may be associated with neurocognitive damage. METHODS: A retrospective review of consecutive EOS patients from February to December 2017 who received an MRI of the cervical, thoracic, and lumbar spine was conducted. MRI images were reviewed for neural axis abnormalities. Two sequences (sagittal T1, sagittal T2) of these previously reviewed MRIs were read at a separate time by an attending pediatric neuroradiologist. The imaging findings from these two select sequences were then compared with the prior radiology report based on all of the standard MRI sequences. RESULTS: Fifty patients met criteria. Ten patients (20%) had neural axis abnormalities detected by the full MRI. All of these neural axis abnormalities were detected on the combination of sagittal T1 + sagittal T2 images. Standard MRIs lasted 66 ± 20 minutes and patients required 90 ± 22 minutes of anesthesia. Sagittal T1 + sagittal T2 sequences lasted 21 ± 7 minutes (P < 0.0001). CONCLUSION: Limited sequence MRIs with sagittal T1 and T2 sequences for EOS patients had 100% sensitivity for the detection of neural axis abnormalities and would allow for a 68% reduction in the length of MRI and significant reduction in anesthesia time. LEVEL OF EVIDENCE: 3.
引用
- Murgai RR, Tamrazi B, Illingworth KD, et al. Limited Sequence MRIs for Early Onset Scoliosis Patients Detected 100% of Neural Axis Abnormalities While Reducing MRI Time by 68. Spine (Phila Pa 1976). 2019. PMID: 30540716. doi:10.1097/BRS.0000000000002966
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。