文献速递关节外科创伤骨科

挪威髋部骨折登记研究:治疗髋部骨折时,抛光锥形柄骨水泥半髋置换术后假体周围骨折再手术率高于解剖型与直柄

More reoperations for periprosthetic fracture after cemented hemiarthroplasty with polished taper-slip stems than after anatomical and straight stems in the treatment of hip fractures: a study from the Norwegian Hip Fracture Register 2005 to 2016.
PubMed 文献 · Bone Joint J · 2018-01-01

抛光锥形柄假体周围骨折再手术几乎独占,Lubinus SP2、Charnley与Spectron EF柄一年后再手术风险低于Exeter柄。

要点

  • 抛光锥形柄(Exeter与CPT)假体周围骨折再手术几乎仅见于此类柄。
  • 一年后再手术风险:Lubinus SP2 HR 0.77(95%CI 0.60-0.97)、Charnley HR 0.64(95%CI 0.48-0.86)、Spectron EF HR 0.44(95%CI 0.29-0.67),均低于Exeter柄。
  • 作者结论认为解剖型与直柄在再手术率上似乎优于抛光锥形柄。

核心结论

  • 骨水泥半髋置换治疗髋部骨折的假体生存率高。
  • 再手术率差异似乎有利于解剖型和直柄,抛光锥形柄假体周围骨折风险更高。

研究设计与样本

  • 基于挪威髋部骨折登记(NHFR)的大规模登记研究,纳入2005至2016年70岁以上股骨颈骨折行初次骨水泥双极半髋置换共20532例。
  • 抛光锥形柄组n=12065(Exeter和CPT),直柄组n=5545(Charnley、Charnley Modular和Spectron EF),解剖型柄组n=2922(Lubinus SP2)。
  • 以任何再手术为终点采用Kaplan-Meier法计算假体生存率及危险比(HR),不同再手术指征采用Cox回归分析。

主要发现

  • 一年生存率:Exeter柄96.0%(95%CI 95.6-96.4),Lubinus SP2柄97.0%(95%CI 96.4-97.6),Charnley柄97.6%(95%CI 97.0-98.2),Spectron EF柄98.1%(95%CI 97.3-98.9),Charnley Modular柄96.4%(95%CI 95.6-97.2)。
  • 与Exeter柄相比,一年后再手术风险:Lubinus SP2 HR 0.77(95%CI 0.60-0.97),Charnley HR 0.64(95%CI 0.48-0.86),Spectron EF HR 0.44(95%CI 0.29-0.67)。
  • 假体周围骨折再手术几乎仅发生于抛光锥形柄使用后。

临床怎么用

  • 作者结论认为再手术率差异似乎有利于解剖型和直柄,抛光锥形柄假体周围骨折风险更高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this large registry-based study was to compare mid-term survival rates of cemented femoral stems of different designs used in hemiarthroplasty for a fracture of the femoral neck. PATIENTS AND METHODS: From the Norwegian Hip Fracture Register (NHFR), 20 532 primary cemented bipolar hemiarthroplasties, which were undertaken in patients aged > 70 years with a femoral neck fracture between 2005 and 2016, were included. Polished tapered stems (n = 12 065) (Exeter and CPT), straight stems (n = 5545) (Charnley, Charnley Modular, and Spectron EF), and anatomical stems (n = 2922) (Lubinus SP2) were included. The survival of the implant with any reoperation as the endpoint was calculated using the Kaplan-Meier method and hazard ratios (HRs), and the different indications for reoperation were calculated using Cox regression analysis. RESULTS: The one-year survival was 96.0% (95% confidence interval (CI) 95.6 to 96.4) for the Exeter stem, 97.0% (95% CI 96.4 to 97.6) for the Lubinus SP2 stem, 97.6% (95% CI 97.0 to 98.2) for the Charnley stem, 98.1% (95% CI 97.3 to 98.9) for the Spectron EF stem, and 96.4% (95% CI 95.6 to 97.2) for the Charnley Modular stem, respectively. The hazard ratio for reoperation after one year was lower for Lubinus SP2 (HR 0.77, 95% CI 0.60 to 0.97), Charnley (HR 0.64, 95% CI 0.48 to 0.86), and Spectron EF stems (HR 0.44, 95% CI 0.29 to 0.67) compared with the Exeter stem. Reoperation for periprosthetic fracture occurred almost exclusively after the use of polished tapered stems. CONCLUSION: We were able to confirm that implant survival after cemented hemiarthroplasty for a hip fracture is high. Differences in rates of reoperation seem to favour anatomical and straight stems compared with polished tapered stems, which had a higher risk of periprosthetic fracture.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Kristensen TB, Dybvik E, Furnes O, et al. More reoperations for periprosthetic fracture after cemented hemiarthroplasty with polished taper-slip stems than after anatomical and straight stems in the treatment of hip fractures: a study from the Norwegian Hip Fracture Register 2005 to 2016. Bone Joint J. 2018. PMID: 30499310. doi:10.1302/0301-620X.100B12.BJJ-2018-0262.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。