缝线纽扣与下胫腓螺钉治疗下胫腓联合损伤:随机对照试验的Meta分析
该Meta分析纳入5项随机对照试验,比较缝线纽扣(SB)与下胫腓螺钉(SS)固定下胫腓联合损伤的疗效,共143例SB组与142例SS组患者。SB组术后美国足踝外科协会(AOFAS)评分更高(95.3 vs 86.7,P<.001),内置物断裂率(0.0% vs 25.4%,P<.001)、内置物取出率(6.0% vs 22.4%,P=.01)及关节复位不良率(0.8% vs 11.5%,P=.05)均更低。作者认为SB技术优于SS技术,并据此提出A级推荐。
要点
- SB组术后平均20.8个月AOFAS评分95.3,高于SS组的86.7(P<.001)。
- SB组内置物断裂率0.0%,低于SS组的25.4%(P<.001)。
- SB组内置物取出率6.0%、关节复位不良率0.8%,分别低于SS组的22.4%(P=.01)和11.5%(P=.05)。
核心结论
- SB技术可改善功能结局,并降低内置物断裂和关节复位不良的发生率。
- 基于该Meta分析结果,作者认为SB技术相较SS技术治疗下胫腓联合损伤 warrants A级推荐。
研究设计与样本
- 研究设计为Meta分析,按照PRISMA指南进行文献检索,纳入比较SB与SS技术治疗下胫腓联合损伤的随机对照试验。
- 共纳入5项临床研究,SB组143例患者,SS组142例患者。
- 证据等级依据牛津循证医学中心(Oxford Centre for Evidence-Based Medicine)标准评估,统计分析使用RevMan软件,P值≤.05视为有统计学意义。
主要发现
- SB组术后平均20.8个月AOFAS评分为95.3,SS组为86.7(P<.001)。
- SB组内置物断裂率为0.0%,SS组为25.4%(P<.001)。
- SB组内置物取出率为6.0%,SS组为22.4%(P=.01)。
- SB组关节复位不良率为0.8%,SS组为11.5%(P=.05)。
关键数值与推荐
- SB组术后平均20.8个月AOFAS评分95.3 vs SS组86.7(P<.001)。
- SB组内置物断裂率0.0% vs SS组25.4%(P<.001)。
- SB组内置物取出率6.0% vs SS组22.4%(P=.01)。
- SB组关节复位不良率0.8% vs SS组11.5%(P=.05)。
- 作者基于该Meta分析结果提出SB技术相较SS技术治疗下胫腓联合损伤的A级推荐。
临床怎么用
- 对于不稳定性下胫腓联合损伤,原文作者基于该Meta分析结果提出SB技术相较SS技术的A级推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Operative treatment is indicated for unstable syndesmosis injuries, and approximately 20% of all ankle fractures require operative fixation for syndesmosis injuries. PURPOSE: To perform a meta-analysis of randomized controlled trials evaluating clinical outcomes between suture button (SB) and syndesmotic screw (SS) fixation techniques for syndesmosis injuries of the ankle. STUDY DESIGN: Meta-analysis. METHODS: A literature search was performed according to the PRISMA guidelines to identify randomized controlled trials comparing the SB and SS techniques for syndesmosis injuries. Level of evidence was assessed per the criteria of the Oxford Centre for Evidence-Based Medicine. Statistical analysis was performed with RevMan, and a P value ≤.05 was considered statistically significant. RESULTS: Five clinical studies were identified, allowing comparison of 143 patients in the SB group with 142 patients in the SS group. Patients treated with the SB technique had a higher postoperative American Orthopaedic Foot & Ankle Society score at a mean 20.8 months (95.3 vs 86.7, P < .001). The SB group resulted in a lower rate of broken implants (0.0% vs 25.4%, P < .001), implant removal (6.0% vs 22.4%, P = .01), and joint malreduction (0.8% vs 11.5%, P = .05) as compared with the SS group. CONCLUSION: The SB technique results in improved functional outcomes as well as lower rates of broken implant and joint malreduction. Based on the findings of this meta-analysis, the SB technique warrants a grade A recommendation by comparison with the SS technique for the treatment of syndesmosis injuries.
引用
- Shimozono Y, Hurley ET, Myerson CL, et al. Suture Button Versus Syndesmotic Screw for Syndesmosis Injuries: A Meta-analysis of Randomized Controlled Trials. Am J Sports Med. 2018. PMID: 30475639. doi:10.1177/0363546518804804
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。