肩袖修复术后锚钉周围囊肿形成的随时间变化:影响因素与结局
前瞻性纳入40例连续接受关节镜下中大型肩袖撕裂修复并使用同一种生物复合材料内排锚钉的患者,于术后6个月和18个月行MRI评估锚钉周围囊肿形成、锚钉吸收及愈合失败。囊肿发生率从6个月的60.0%降至18个月的18.4%,18个月时73.7%患者锚钉完全或近完全吸收。持续性囊肿与撕裂前后径更大(P=.002)及回缩更大(P<.001)相关,但与愈合失败和功能结局无差异。
要点
- 术后6个月锚钉周围囊肿发生率60.0%,18个月降至18.4%,发生率和严重程度随时间下降。
- 6个月时无锚钉吸收,18个月时73.7%患者锚钉完全或近完全吸收。
- 持续性锚钉周围囊肿与撕裂前后径更大(P=.002)及回缩更大(P<.001)相关。
核心结论
- 锚钉周围囊肿的发生率和严重程度随时间下降,大多数生物复合材料缝合锚钉在术后18个月被吸收。
- 持续性锚钉周围囊肿与撕裂前后径更大和回缩更大相关。
研究设计与样本
- 病例对照研究,证据等级3。
- 前瞻性连续纳入40例因中大型肩袖撕裂接受关节镜修复并使用单一类型生物复合材料(聚左旋乳酸/聚乙醇酸-β磷酸三钙)内排锚钉的患者,平均年龄61.10±5.79岁。
- 于术后2个时间点(6个月和18个月)行磁共振成像(MRI),评估锚钉周围囊肿形成、锚钉吸收和愈合失败;收集人口学和临床数据,评估术后至少18个月的功能结局。
主要发现
- 术后6个月,24例患者(60.0%总计;1级35.0%;2级10.0%;3级7.5%;4级7.5%)观察到锚钉周围囊肿。
- 术后18个月,7例患者(18.4%总计;1级7.9%;2级5.3%;3级2.6%;4级2.6%)存在持续性锚钉周围囊肿。
- 6个月时无锚钉吸收,但18个月时73.7%患者显示完全或近完全吸收。
- 持续性锚钉周围囊肿患者的前后径撕裂尺寸显著更大(P=.002)且回缩更大(P<.001)。
- 有无持续性锚钉周围囊肿的患者在愈合失败和功能结局方面无差异(所有P>.05);大结节与小节结插入的锚钉在锚钉周围囊肿形成和锚钉吸收方面无差异(所有P>.05)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: There is a lack of knowledge about the changes in perianchor cysts over time and the factors related to perianchor cysts. PURPOSE: To evaluate the changes in perianchor cyst formation and anchor absorption over time after arthroscopic rotator cuff repair with a biocomposite suture anchor and to evaluate the factors affecting perianchor cyst persistence and their relationship with patient outcomes. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: Forty consecutive patients (mean age, 61.10 ± 5.79 years) who underwent arthroscopic repair for medium- to large-sized rotator cuff tears using a single type of biocomposite (poly-L-lactic acid/polyglycolic acid-beta tricalcium phosphate) medial-row anchor were prospectively enrolled. Postoperative magnetic resonance imaging (MRI) at 2 different time points (6 and 18 months) was performed, and perianchor cyst formation, anchor absorption, and healing failures were evaluated using postoperative MRI. Demographic and clinical data were collected, and functional outcomes at a minimum of 18 months after surgery were assessed. RESULTS: Perianchor cysts were observed in 24 patients (60.0% total; grade 1: 35.0%; grade 2: 10.0%; grade 3: 7.5%; grade 4: 7.5%) at 6 months, and 7 patients (18.4% total; grade 1: 7.9%; grade 2: 5.3%; grade 3: 2.6%; grade 4: 2.6%) had a persistent perianchor cyst at 18 months after surgery. No anchors were absorbed at 6 months, but 73.7% of patients revealed complete or near-full absorption at 18 months. Patients with persistent perianchor cysts showed a significantly larger tear size in the anteroposterior dimension ( P = .002) and greater retraction ( P < .001). There were no differences in healing failures and functional outcomes between patients with and without persisting perianchor cysts (all P > .05). No differences were found in perianchor cyst formation and anchor absorption between anchors inserted in the greater tuberosity and the lesser tuberosity (all P > .05). CONCLUSION: The incidence and severity of perianchor cysts decreased with time, and most biocomposite suture anchors were absorbed at 18 months after surgery. Persisting perianchor cysts correlated with a larger tear size in the anteroposterior dimension and greater retraction.
引用
- Chung SW, Lee YS, Kim JY, et al. Changes in Perianchor Cyst Formation Over Time After Rotator Cuff Repair: Influential Factors and Outcomes. Am J Sports Med. 2018. PMID: 30485118. doi:10.1177/0363546518810517
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。