孤立性内侧间室骨关节炎患者远端股骨旋转与术前胫骨近端内翻角无关
本研究纳入孤立性内侧间室骨关节炎患者,检验术前负重长腿X线片上胫骨平台-胫骨干(TPTS)角与临床后髁角(cPCA)的相关性。结果未发现TPTS角与cPCA相关(P = .15),轻度内翻组(TPTS ≤4°)与中度内翻组(TPTS >4°)的cPCA无统计学显著差异(P = .62)。作者认为不能通过胫骨内翻预测股骨远端旋转。
要点
- TPTS角与cPCA无相关性(P = .15)。
- 轻度内翻组与中度内翻组cPCA无统计学显著差异(P = .62)。
- 作者认为不应使用胫骨近端内翻术前预测股骨假体外旋。
核心结论
- 本研究不支持既往研究的结论,提示不能通过术前长腿X线片测量的胫骨内翻来预测股骨远端旋转量。
- 作者认为,对于孤立性内侧间室骨关节炎患者,不应使用胫骨近端内翻来术前预测股骨假体的外旋。
研究设计与样本
- 本研究为以孤立性内侧间室骨关节炎患者为对象的临床研究,需至少68例患者以达到80%检验效能。
- 纳入标准为原发性内侧间室骨关节炎,排除外翻机械轴患者。
- 临床后髁角(cPCA)定义为解剖经上髁轴与后髁线之间的角度。
- 按TPTS角将患者分为两组:TPTS ≤4°(轻度内翻)和TPTS >4°(中度内翻)。
- 采用相关性分析检验TPTS与cPCA之间的关系,组间机械轴和旋转测量采用独立t检验比较。
主要发现
- 平均机械轴为内翻6.9°,平均TPTS角为内翻4.8°。
- 平均cPCA为5.0°(标准差[SD] 1.4°;范围2.4°-7.9°)。
- TPTS角与cPCA之间未发现相关性(P = .15)。
- 轻度内翻组(n = 28例)平均cPCA为5.2°(SD 1.5°;范围2.7°-7.9°),中度内翻组(n = 45例)平均cPCA为4.4°(SD 1.7°;范围0.6°-7.5°)。
- 两组间cPCA无统计学显著差异(P = .62)。
关键数值与推荐
- TPTS ≤4°定义为轻度内翻,TPTS >4°定义为中度内翻。
- cPCA定义为解剖经上髁轴与后髁线之间的角度。
临床怎么用
- 作者认为,不应使用胫骨近端内翻来术前预测孤立性内侧间室骨关节炎患者股骨假体的外旋。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Prior studies have found that greater proximal tibial varus was associated with increased external femoral rotation at time of total knee arthroplasty. These works suggest that measuring the tibial plateau-tibial shaft (TPTS) angle on preoperative weight-bearing long leg radiographs could predict significant variations in the posterior condylar angle. METHODS: A minimum of 68 patients were needed to reach 80% power. Patients were included if they had primary medial compartment osteoarthritis and excluded if they had a valgus mechanical axis. The clinical posterior condylar angle (cPCA) was defined as the angle between the anatomic transepicondylar axis and posterior condylar line. Correlation analyses were performed to test for any relationship between the TPTS and cPCA. Two patient groups were created based on TPTS angle: TPTS ≤4° (mild varus) and TPTS >4° (moderate varus). Mechanical axis and rotational measurements were compared between the groups using independent t-tests. RESULTS: The mean mechanical axis and TPTS angle were 6.9° and 4.8° of varus, respectively. The mean cPCA was 5.0° (standard deviation [SD], 1.4°; range, 2.4°-7.9°). No correlation was found between the TPTS angle and cPCA (P = .15). The mean cPCA in the mild varus group (n = 28 patients) was 5.2° (SD, 1.5°; range, 2.7°-7.9°), and the mean cPCA in the moderate varus group (n = 45 patients) was 4.4° (SD, 1.7°; range, 0.6°-7.5°). These groups were not statistically significantly different from each other (P = .62). CONCLUSION: The present study does not support the conclusions of previous works and suggests that the amount of distal femoral rotation cannot be predicted by tibial varus alignment measured on preoperative long leg radiographs. Consequently, we believe that proximal tibial varus should not be used to preoperatively predict external rotation of the femoral component in patients with isolated medial compartment osteoarthritis.
引用
- Conti MS, Kleeblad LJ, Jones CW, et al. Distal Femoral Rotation is not Associated With Preoperative Proximal Tibial Varus Angle in Patients With Isolated Medial Compartment Osteoarthritis. J Arthroplasty. 2018. PMID: 30377013. doi:10.1016/j.arth.2018.09.080