文献速递关节外科创伤骨科

杯笼重建治疗严重髋臼骨缺损与骨盆不连续:35例连续病例的中期结果

Cup-cage reconstruction for severe acetabular bone loss and pelvic discontinuity: Mid-term Results of a Consecutive Series of 35 Cases.
PubMed 文献 · Bone Joint J · 2018-01-01

回顾性单中心系列35髋(34例)采用小梁金属杯联合钛笼的杯笼重建治疗严重髋臼骨缺损,平均随访47个月;5年因任何原因翻修的假体生存率为89%(95%CI 72-96),Harris髋关节评分从术前平均30显著改善至末次随访71(p<0.001),作者认为杯笼重建是涉及后柱的大段骨缺损和骨盆不连续的可选方案。

要点

  • 5年因任何原因翻修的假体生存率为89%(95%CI 72-96),无异无菌性松动需翻修。
  • Harris髋关节评分从术前平均30改善至末次随访71(p<0.001)。
  • 并发症包括髋关节脱位2例(6%)、假体周围感染2例(6%)及坐骨神经刺激需去除笼坐骨翼1例(3%)。

核心结论

  • 作者认为杯笼重建是涉及后柱的大段骨缺损和骨盆不连续的可选方案。
  • 该技术可使髋臼中心得到充分恢复,总体稳定性良好,术后功能满意。
  • 不稳定和感染仍是这些复杂翻修病例的缺点。

研究设计与样本

  • 回顾性单中心连续病例系列,纳入2011年至2015年间因严重髋臼骨缺损接受杯笼重建(小梁金属壳联合钛笼)的35髋(34例,男7例、女27例)。
  • 手术时平均年龄70岁(42至85岁),所有患者髋臼缺损为Paprosky 2C型至3B型,其中24髋(69%)存在骨盆不连续。
  • 平均随访47个月(25至84个月)。

主要发现

  • 以任何原因翻修计算的5年累积假体生存率为89%(95%CI 72-96),有8髋处于风险中。
  • 无异无菌性松动需翻修;1例1髋(3%)因坐骨神经刺激需去除笼的坐骨翼。
  • 2例(6%;2髋)发生髋关节脱位,其中1例1髋需翻修,将双动髋臼假体骨水泥固定于固定良好的杯笼结构内。
  • 2例(6%;2髋)发生假体周围感染,1例经两阶段翻修手术成功控制,另1例因严重内科合并症行关节切除术。
  • Harris髋关节评分从术前平均30(15至51)显著改善至末次随访71(40至89)(p < 0.001)。

临床怎么用

  • 作者认为杯笼重建是涉及后柱的大段骨缺损和骨盆不连续的可选方案。
  • 作者指出该技术可使髋臼中心得到充分恢复,总体稳定性良好,术后功能满意。
  • 作者指出不稳定和感染仍是这些复杂翻修病例的缺点。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Severe acetabular bone loss and pelvic discontinuity (PD) present particular challenges in revision total hip arthroplasty. To deal with such complex situations, cup-cage reconstruction has emerged as an option for treating this situation. We aimed to examine our success in using this technique for these anatomical problems. PATIENTS AND METHODS: We undertook a retrospective, single-centre series of 35 hips in 34 patients (seven male, 27 female) treated with a cup-cage construct using a trabecular metal shell in conjunction with a titanium cage, for severe acetabular bone loss between 2011 and 2015. The mean age at the time of surgery was 70 years (42 to 85) and all patients had an acetabular defect graded as Paprosky Type 2C through to 3B, with 24 hips (69%) having PD. The mean follow-up was 47 months (25 to 84). RESULTS: The cumulative five-year survivorship of the implant with revision for any cause was 89% (95% confidence interval (CI) 72 to 96) with eight hips at risk. No revision was required for aseptic loosening; however, one patient with one hip (3%) required removal of the ischial flange of the cage due to sciatic nerve irritation. Two patients (6%; two hips) suffered from hip dislocation, whereas one patient (one hip) required revision surgery with cement fixation of a dual-mobility acetababular component into a well-fixed cup-cage construct. Two patients (6%; two hips) developed periprosthetic infection. One patient was successfully controlled with a two-stage revision surgery, while the other patient underwent excision arthroplasty due to severe medical comorbidities. For the whole series, the Harris Hip Score significantly improved from a mean of 30 (15 to 51) preoperatively to 71 (40 to 89) at the latest follow-up (p < 0.001). CONCLUSION: Our findings suggest that cup-cage reconstruction is a viable option for major segmental bone defects involving the posterior column and PD. It allows adequate restoration of the acetabulum centre with generally good stability and satisfactory postoperative function. Instability and infection remain drawbacks in these challenging revision cases. Cite this article: Bone Joint J 2018;100-B:1442-48.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Hipfl C, Janz V, Löchel J, et al. Cup-cage reconstruction for severe acetabular bone loss and pelvic discontinuity: Mid-term Results of a Consecutive Series of 35 Cases. Bone Joint J. 2018. PMID: 30418066. doi:10.1302/0301-620X.100B11.BJJ-2018-0481.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。