假体宽度与深度对颈椎间盘置换术后异位骨化的影响
回顾性分析102例接受Prestige-LP椎间盘置换的患者,按McAfee分类分为异位骨化组35例与非异位骨化组67例,平均随访47.7个月,总体异位骨化发生率为34.3%(35/102)。异位骨化组假体宽度比与深度比均小于非异位骨化组(0.869 vs 0.897,P=0.033;0.888 vs 0.948,P<0.001),异位骨化组手术节段活动度小于非异位骨化组(5.3° vs 9.0°),但临床评分无显著差异。
要点
- 假体对终板宽度和深度覆盖不足可能与异位骨化形成有关。
- 异位骨化组手术节段活动度低于非异位骨化组(5.3° vs 9.0°)。
- 两组VAS、NDI、JOA评分及C2-7角、节段角无显著差异。
核心结论
- 部分假体在宽度和深度上对终板覆盖不足,覆盖不足可能诱导异位骨化形成。
- 异位骨化可降低手术节段活动度,但不影响临床结局。
研究设计与样本
- 回顾性分析本研究所接受Prestige-LP椎间盘颈椎间盘置换术的患者,按McAfee分类分为异位骨化组(35例)与非异位骨化组(67例)。
- 计算假体宽度与深度分别对终板的比值(Rw与Rd),并进行影像学与临床评估。
- 证据等级为3级。
主要发现
- 平均随访47.7个月,末次随访时异位骨化总体发生率为34.3%(35/102)。
- 总体Rw为0.887±0.057,总体Rd为0.927±0.048。
- 异位骨化组Rw小于非异位骨化组(0.869 vs 0.897,P=0.033),异位骨化组Rd小于非异位骨化组(0.888 vs 0.948,P<0.001)。
- 两组VAS、NDI、JOA评分、C2-7角及节段角无显著差异。
- 异位骨化组手术节段活动度小于非异位骨化组(5.3° vs 9.0°)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Retrospective analysis. OBJECTIVE: To investigate the effect of width and depth of the inserted cervical disc prosthesis on heterotopic ossification (HO) after cervical disc arthroplasty, and to explore the relationship between clinical outcome and HO. SUMMARY OF BACKGROUND DATA: The mechanism of HO formation still remains unknown. Footprint mismatch of cervical disc prosthesis was common in cervical arthroplasty. Compared with endplate, some inserted prostheses were smaller in width and length. METHODS: Retrospectively analyze the patients who underwent cervical disc arthroplasty with Prestige-LP Disc in our institute. Patients were divided into HO group or non-HO group according to the McAfee classification. The ratios of the width (Rw) and depth (Rd) of prosthesis to endplate were calculated. Radiographic and clinical assessments included: C2-7 angle, segmental angle, range of motion (ROM) of the index level, visual analogue scale, neck disability index, and Japanese orthopaedic association scores. RESULTS: The mean follow-up time was 47.7 months. At the last follow-up, the overall incidence of HO was 34.3% (35/102). There were 35 patients in the HO-group, and 67 patients in the non-HO group. The overall Rw and Rd were 0.887 ± 0.057 and 0.927 ± 0.048, respectively. Both the Rw and Rd of HO-group were smaller than those of non-HO group (0.869 vs. 0.897, P = 0.033; 0.888 vs. 0.948, P < 0.001). There were no significant differences in visual analogue scale, neck disability index, or Japanese orthopaedic association scores, C2-7 angle, or segmental angle between the two groups. But the HO group had less ROM of the index level than the non-HO group (5.3° vs. 9.0°). CONCLUSION: Some of prosthesis had insufficient coverage to the endplate in width and depth. Insufficient coverage of endplate in width and depth may induce the formation of HO. HO could reduce the ROM of the index level, but did not influence the clinical outcome. LEVEL OF EVIDENCE: 3.
引用
- Zeng J, Liu H, Chen H, et al. Effect of Prosthesis Width and Depth on Heterotopic Ossification After Cervical Disc Arthroplasty. Spine (Phila Pa 1976). 2019. PMID: 30395084. doi:10.1097/BRS.0000000000002915
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。