功能性安全区优于Lewinnek安全区用于全髋关节置换术:为何Lewinnek安全区不总能预测稳定性
本研究回顾分析320髋(291例)初次全髋关节置换术(THA)患者,296髋(92.5%)位于Lewinnek安全区。其中254髋(85.8%)同时位于功能性安全区,42髋位于功能性安全区外,被认为是脱位风险。股骨活动度是预测位于功能性安全区外的最佳因素。
要点
- 在Lewinnek安全区内的296髋中,85.8%同时位于功能性安全区,14.2%位于功能性安全区外。
- 位于功能性安全区外的预测因素包括股骨活动度增加、脊柱骨盆活动度降低和骨盆入射角。
- 股骨活动度是术前和术后预测位于功能性安全区外的最佳因素,而非矢状面髋臼杯位置。
核心结论
- 在Lewinnek安全区内的髋中,14.2%位于功能性安全区外,这可能是髋关节脱位的一个潜在原因,即使髋臼杯角度正常。
研究设计与样本
- 回顾性综述(证据等级III),320髋(291例患者)接受计算机导航初次全髋关节置换术,所有患者均有术前和术后站立位及坐位脊柱骨盆侧位X线片。
主要发现
- 296髋(92.5%)位于Lewinnek安全区(外倾角40°±10°,前倾角15°±10°),其中254髋(85.8%)同时位于功能性安全区。
- 42例患者基于联合矢状面指数(CSI)位于功能性安全区外,其中19例站立位CSI增加,23例坐位CSI降低,均被认为存在脱位风险。
- 位于功能性安全区外的预测因素为股骨活动度增加(P < .001, r = 0.632)、脊柱骨盆活动度降低(P < .001, r = 0.455)和骨盆入射角(P < .001, r = 0.400)。
局限性
- 证据等级III,回顾性综述。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The Lewinnek "safe zone" is not always predictive of stability after total hip arthroplasty (THA). Recent studies have focused on functional hip motion as observed on lateral spine-pelvis-hip x-rays. The purpose of this study was to assess the correlation between the Lewinnek safe zone and the functional safe zone based on hip and pelvic motion in the sagittal plane. METHODS: Three hundred twenty hips (291 patients) underwent primary THA using computer navigation. Two hundred ninety-six of these hips (92.5%) were within the Lewinnek safe zone as determined by inclination of 40° ± 10° and anteversion of 15° ± 10°. All patients had preoperative and postoperative standing and sitting lateral spinopelvic x-rays. The combined sagittal index (CSI), a combination of sagittal acetabular and femoral position, was measured for each patient and used to assess the functional safe zone. Data analysis was performed to identify hips in the Lewinnek safe zone inside and outside the sagittal functional safe zone. Predictive factors for hips outside the functional safe zone were identified. RESULTS: Of the 296 hips within the Lewinnek safe zone, 254 (85.8%) were also in the functional safe zone. Forty-two patients were outside the functional safe zone based on CSI; 19 had an increased standing CSI and 23 had a decreased sitting CSI, all were considered at risk for dislocation. Predictive factors for falling outside the functional safe zone were increased femoral mobility (P < .001, r = 0.632), decreased spinopelvic mobility (P < .001, r = 0.455), and pelvic incidence (P < .001, r = 0.400). CONCLUSION: In this study, 14.2% of hips within the Lewinnek safe zone were outside the functional safe zone, identifying a potential reason hips dislocate despite having "normal" cup angles. The best predictor for falling outside the functional safe zone, both preoperatively and postoperatively, was femoral mobility, not the sagittal cup position (ie, cup anteinclination). LEVEL OF EVIDENCE: Level III, retrospective review.
引用
- Tezuka T, Heckmann ND, Bodner RJ, et al. Functional Safe Zone Is Superior to the Lewinnek Safe Zone for Total Hip Arthroplasty: Why the Lewinnek Safe Zone Is Not Always Predictive of Stability. J Arthroplasty. 2018. PMID: 30454867. doi:10.1016/j.arth.2018.10.034
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。