文献速递关节外科创伤骨科

中东人群股骨颈骨折全髋关节置换术中双动杯的死亡率和中期结局

Mortality Rate and Mid-Term Outcomes of Total Hip Arthroplasty Using Dual Mobility Cups for the Treatment of Femoral Neck Fractures in a Middle Eastern Population.
PubMed 文献 · J Arthroplasty · 2018-11-01

研究评估中东人群股骨颈骨折行双动杯全髋关节置换术后的死亡率、临床和功能结局。初始174例患者(177髋)中18例(10.3%)死亡,最终125例(125髋)无脱位、无菌性松动或感染,平均改良髋关节Harris评分为94.8±8.4。作者认为双动杯植入物显示出优异的临床和功能结果。

要点

  • 最终125例(125髋)中无脱位、无菌性松动或感染发生。
  • 平均改良髋关节Harris评分为94.8±8.4。
  • 40例有极端髋部体位习俗的患者中36例(90%)术后描述其髋为「被遗忘的髋」。

核心结论

  • 双动杯植入物显示出优异的临床和功能结果。
  • 大多数有涉及极端髋部体位仪式和习俗的患者能够恢复日常活动。
  • 观察到的低死亡率应促使未来研究探讨其与双动杯使用之间的相关性。

研究设计与样本

  • 研究纳入初始样本174例患者(177个手术髋),最终样本为125例患者(125髋),评估股骨颈骨折行双动杯全髋关节置换术后的死亡率、临床和功能结局。

主要发现

  • 初始174例患者(177髋)中18例(10.3%)患者(20髋)在平均39.6±13.8个月(范围2至49个月)后死亡,其中仅3例(1.7%)发生在术后第一年。
  • 12例患者(13髋)失访,19例患者(19髋)放射学数据不完整。
  • 最终125例患者(125髋)中未遇到脱位、无菌性松动或感染。
  • 平均改良髋关节Harris评分为94.8±8.4;40例经常练习东方坐姿或祈祷的患者平均改良髋关节Harris评分为94.1±3.1。
  • 术后,这40例患者中36例(90%)将他们的髋描述为「被遗忘的髋」;多变量分析仅发现死亡率与心血管合并症之间存在相关性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The dual mobility cups (DMCs) were shown to reduce dislocation rate following total hip arthroplasty for any etiology, including femoral neck fractures. No reported studies evaluating DMC results for femoral neck fracture in a Middle Eastern population were found in the literature. METHODS: This study aims to look for mortality rate, clinical, and functional outcomes in a population having specific rituals involving extreme hip positions as part of their daily activities. RESULTS: Of an initial sample of 174 patients (177 operated hips), 18 (10.3%) patients (20 hips) died after a mean of 39.6 ± 13.8 months (ranging from 2 to 49 months) with only 3 (1.7%) during the first post-operative year. Twelve patients (13 hips) were lost to follow-up and 19 patients (19 hips) had their radiological data incomplete. In the final sample of 125 patients (125 hips), no dislocation, aseptic loosening, or infection was encountered. The mean modified Hip Harris Score was of 94.8 ± 8.4. The mean modified Hip Harris Score of 40 patients who used to practice regularly oriental sitting position or prayers was 94.1 ± 3.1. After surgery, 36 of these 40 patients (90%) described their hip as "a forgotten hip." Multivariate analyses found correlation only between mortality and cardiovascular co-morbidities. CONCLUSION: DMC implants showed excellent clinical and functional results. The majority of patients having rituals and customs involving extreme hip positions were able to resume their daily activities. The observed low mortality rate should incite future research to investigate its correlation with the use of DMCs.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Assi CC, Barakat HB, Caton JH, et al. Mortality Rate and Mid-Term Outcomes of Total Hip Arthroplasty Using Dual Mobility Cups for the Treatment of Femoral Neck Fractures in a Middle Eastern Population. J Arthroplasty. 2018. PMID: 30459008. doi:10.1016/j.arth.2018.10.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。