文献速递关节外科

辐照同种异体骨用于髋臼重建的长期结果

Long-term results of acetabular reconstruction using irradiated allograft bone.
PubMed 文献 · Bone Joint J · 2018-01-01

该研究回顾了1990年至2000年间123髋(110例)因无菌性松动行髋臼重建的病例,采用冷冻、辐照、磨碎股骨头打压植骨联合骨水泥髋臼假体。平均随访16.9年,23髋(18.7%)接受翻修,15年生存率80.6%,20年生存率73.7%,作者认为该方法长期结果满意。

要点

  • 平均随访16.9年,23髋(18.7%)翻修,其中感染10髋、无菌性松动8髋、脱位3髋。
  • 可再评估的66髋中50髋(75.6%)功能满意,所有存活假体植骨均愈合。
  • 全因生存率15年80.6%(95%CI 71.1-87.2),20年73.7%(95%CI 61.6-82.5)。

核心结论

  • 采用冷冻、辐照、磨碎同种异体骨打压植骨联合骨水泥髋臼假体行髋臼重建是一种有效的治疗方法,长期结果满意,与其他重建类型相当。

研究设计与样本

  • 1990年至2000年间,123髋(110例患者)因无菌性松动行髋臼重建,使用冷冻、辐照、磨碎股骨头打压植骨联合骨水泥髋臼假体;55例男性、55例女性,翻修时平均年龄64.3岁(范围26至97岁)。

主要发现

  • 平均随访16.9年,共23髋(18.7%)翻修,包括感染10髋、无菌性松动8髋、脱位3髋。
  • 可再评估的66髋(58例患者)中,50髋(42例患者;75.6%)功能仍满意。
  • 所有存活假体的植骨均愈合。
  • 全因生存率15年为80.6%(55例有风险,95%CI 71.1至87.2),20年为73.7%(8例有风险,95%CI 61.6至82.5)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The management of acetabular defects at the time of revision hip arthroplasty surgery is a challenge. This study presents the results of a long-term follow-up study of the use of irradiated allograft bone in acetabular reconstruction. PATIENTS AND METHODS: Between 1990 and 2000, 123 hips in 110 patients underwent acetabular reconstruction for aseptic loosening, using impaction bone grafting with frozen, irradiated, and morsellized femoral heads and a cemented acetabular component. A total of 55 men and 55 women with a mean age of 64.3 years (26 to 97) at the time of revision surgery are included in this study. RESULTS: At a mean follow-up of 16.9 years, there had been 23 revisions (18.7%), including ten for infection, eight for aseptic loosening, and three for dislocation. Of the 66 surviving hips (58 patients) that could be reassessed, 50 hips (42 patients; 75.6%) were still functioning satisfactorily. Union of the graft had occurred in all hips with a surviving implant. Survival analysis for all indications was 80.6% at 15 years (55 patients at risk, 95% confidence interval (CI) 71.1 to 87.2) and 73.7% at 20 years (eight patients at risk, 95% CI 61.6 to 82.5). CONCLUSION: Acetabular reconstruction using frozen, irradiated, and morsellized allograft bone and a cemented acetabular component is an effective method of treatment. It gives satisfactory long-term results and is comparable to other types of reconstruction. Cite this article: Bone Joint J 2018;100-B:1449-54.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Green CM, Buckley SC, Hamer AJ, et al. Long-term results of acetabular reconstruction using irradiated allograft bone. Bone Joint J. 2018. PMID: 30418060. doi:10.1302/0301-620X.100B11.BJJ-2018-0478.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。