形态学优化股骨柄直接前入路全髋关节置换术:常规手术台、无透视

Direct Anterior Approach Total Hip Arthroplasty Using a Morphometrically Optimized Femoral Stem, a Conventional Operating Table, Without Fluoroscopy.
PubMed 文献 · J Arthroplasty · 2018-10-26

单外科医生回顾性系列研究纳入1017例直接前入路全髋关节置换术,使用形态学优化的干骺端-骨干匹配锥形股骨柄(非短柄)、常规手术台且无术中透视。至少2年随访时Harris髋关节评分从术前40.7±5.1改善至95.3±4.2,脱位3例(0.3%),翻修15例(1.5%)。作者结论认为该假体设计联合所述技术及要素在2年时显示优异结果,患者需继续随访以证明该装置与技术的持久性。

要点

  • 1017例直接前入路全髋关节置换术在常规手术台、无透视下使用形态学优化锥形股骨柄完成。
  • 至少2年随访Harris髋关节评分从40.7±5.1改善至95.3±4.2,脱位率0.3%,翻修率1.5%。
  • 作者结论认为使用该股骨柄而非短柄可减少组件位置不良并最小化松动风险。

核心结论

  • 作者结论认为,使用形态学优化的干骺端-骨干匹配锥形股骨柄而非短柄可减少组件位置不良并最小化松动风险。
  • 作者认为,联合使用该假体设计与本队列所述技术及要素在2年时显示优异结果。
  • 作者指出患者需继续随访,以证明该装置与技术相较于其他直接前入路全髋关节置换术的进一步持久性。

研究设计与样本

  • 回顾性综述单外科医生系列初次直接前入路全髋关节置换术。
  • 所有手术均在常规手术台上、无透视下使用非骨水泥锥形股骨柄完成。
  • 临床、功能与影像学结果在至少2年时评估。

主要发现

  • 共完成1017例初次全髋关节置换术,术前Harris髋关节评分为40.7±5.1,至少2年随访时改善至95.3±4.2。
  • 脱位3例(0.3%),翻修15例(1.5%):感染7例(0.7%)、假体周围骨折4例(0.4%)、不稳定2例(0.2%)、松动1例(0.1%)、疼痛1例(0.1%)。
  • 5例患者(0.5%)需要输血,1例患者发生深静脉血栓和肺栓塞。
  • 无术中骨折、穿孔或全髋关节置换术相关死亡发生,98.3%确认股骨柄中立位对线。
  • 平均髋臼杯外倾角为38.8°±5.1°,前倾角为16.2°±3.5°;平均腿长差异从术前1.2±0.2 cm矫正至术后0.2±0.1 cm。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Our experience with direct anterior approach total hip arthroplasty (THA) suggests that it can be performed successfully with a morphometrically optimized metaphyseal-diaphyseal engaging femoral stem (NOT a short stem), a regular operating room table (NOT a special custom table), and WITHOUT intraoperative fluoroscopy. We report our minimum 2-year results. METHODS: A retrospective review of a single-surgeon series of primary direct anterior approach THAs was performed. All procedures were performed on a regular table, without fluoroscopy, using a cementless tapered femoral stem. Clinical, functional, and radiographic outcomes were evaluated at a minimum of 2 years. RESULTS: In total, 1017 primary THAs were performed. The preoperative Harris Hip Score was 40.7 ± 5.1 and improved to 95.3 ± 4.2 at minimum 2-year follow-up. There were 3 dislocations (0.3%) and 15 revisions (1.5%): 7 for infection (0.7%), 4 for periprosthetic fractures (0.4%), 2 for instability (0.2%), 1 for loosening (0.1%), and 1 for pain (0.1%). Five patients (0.5%) required blood transfusion. One patient developed deep vein thrombosis and pulmonary embolism. No intraoperative fractures, perforation, or THA-related mortality occurred. Neutral stem alignment was confirmed in 98.3%. Mean cup inclination was 38.8° ± 5.1° and anteversion was 16.2° ± 3.5°. The mean leg-length discrepancy was corrected from 1.2 ± 0.2 cm preoperatively to 0.2 ± 0.1 cm postoperatively. CONCLUSION: Using a morphometrically optimized metaphyseal-diaphyseal engaging tapered femoral stem instead of a short stem reduces component malposition and minimizes risk of loosening. Combining the use of this implant design and the technique and elements described in our cohort demonstrated to have excellent results at 2 years. The patients will need continued follow-up to demonstrate further durability of this device and technique compared to others performing direct anterior THA.