全膝关节置换术后胫骨假体旋转的测量:哪种方法最佳
本研究对70例全膝关节置换术后患者,由3名独立观察者分别采用Berger(二维CT)、Mayo(三维CT)和CTTT(二维轴位CT上胫骨托中心至胫骨结节尖的距离)三种方案评估胫骨假体旋转。结果显示三种方案观察者内信度均为「很好」,Mayo与Berger观察者间信度「很好」,CTTT为「好」;CTTT与Mayo方法r²=0.73,CTTT≤6 mm者92%胫骨假体内旋<9°,CTTT≥10 mm者93%内旋≥9°。三维CT是测量胫骨假体旋转的金标准,CTTT可作为快速筛查工具。
要点
- Mayo(三维CT)观察者内信度0.96、观察者间信度0.87,均为「很好」。
- CTTT观察者内信度0.85、观察者间信度0.79,分别为「很好」和「好」。
- CTTT与Mayo方法r²=0.73,CTTT≤6 mm者92%内旋<9°,CTTT≥10 mm者93%内旋≥9°。
核心结论
- 三维CT是测量胫骨假体旋转对线的金标准。
- CTTT与Mayo方法相关性最强,可作为快速筛查工具可靠使用。
研究设计与样本
- 对70例全膝关节置换术后患者的胫骨假体旋转对线进行评估。
- 由3名独立观察者分别采用Berger(二维CT)、Mayo(三维CT)和CTTT三种方案测量。
- 计算观察者间与观察者内组内相关系数、测量间平均差值及平均测量时间。
主要发现
- 三种方案观察者内信度均为「很好」:Mayo 0.96、Berger 0.85、CTTT 0.85。
- 观察者间信度Mayo 0.87、Berger 0.83均为「很好」,CTTT 0.79为「好」。
- CTTT与Mayo方法比较r²=0.73。
- CTTT测量值≤6 mm者中92%胫骨假体内旋<9°。
- CTTT测量值≥10 mm者中93%胫骨假体内旋≥9°。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Tibial component malrotation is associated with pain, stiffness, and altered patellofemoral kinematics in total knee arthroplasty (TKA). However, measuring tibial component rotation following TKA is difficult. Proposed protocols utilizing computed tomography (CT) lack validity and can be time-consuming. This study aimed to (1) compare the reproducibility of the Berger (two-dimensional CT) and Mayo (three-dimensional CT) protocols and (2) validate a simple measurement technique using an anatomical distance on two-dimensional axial CT-the Center of the Tibial tray to the tip of the Tibial Tubercle (CTTT). METHODS: Rotational alignment of 70 TKA patients was evaluated by 3 independent observers using the Berger, Mayo, and CTTT protocols. The inter-rater and intra-rater interclass correlation coefficients, mean difference between measurements, and the mean measurement times were calculated. RESULTS: The intra-rater reliability for all 3 protocols was rated as "very good" (Mayo 0.96, Berger 0.85, and CTTT 0.85). The inter-rater reliability for the Mayo and the Berger method was rated as "very good" (0.87 and 0.83, respectively), and the CTTT was rated as "good" (0.79). Comparing the CTTT to the Mayo method produced an r2 value of 0.73 with 92% of CTTT measurements ≤6 mm having <9° of tibial component internal rotation and 93% of patients with a CTTT ≥10 mm having ≥9° internal rotation. CONCLUSION: Three-dimensional CT is the gold standard for measuring tibial component rotational alignment. The CTTT has the strongest correlation to the Mayo method and can be reliably used as a rapid screening tool.
引用
- Saffi M, Spangehl MJ, Clarke HD, et al. Measuring Tibial Component Rotation Following Total Knee Arthroplasty: What Is the Best Method? J Arthroplasty. 2018. PMID: 30473230. doi:10.1016/j.arth.2018.10.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。