文献速递关节外科

全膝关节置换术中软组织平衡的判断准确性如何

How Accurately Can Soft Tissue Balance Be Determined in Total Knee Arthroplasty?
PubMed 文献 · J Arthroplasty · 2018-10-11

研究前瞻性分析322例机械对线全膝关节置换术,比较术者判断与压力传感器数据在10°、45°、90°屈膝时的膝关节平衡一致性。术者判断准确率分别为63%、57.5%、63.8%,总体敏感度81%、特异度37.7%,屈膝角度越大判断不平衡的能力越差,传感器使用无时间学习效应。

要点

  • 术者判断与传感器数据相比准确率在10°、45°、90°分别为63%、57.5%、63.8%。
  • 术者判断总体敏感度81%、特异度37.7%,识别不平衡膝关节能力有限。
  • 屈膝角度增大时术者判断特异度下降,10°、45°、90°分别为53.5%、34.8%、24.8%。

核心结论

  • 与传感器数据相比,术者判断是真实软组织平衡的较差预测指标,尤其在判断膝关节是否不平衡时。
  • 增加传感器使用并未提高术者判断膝关节平衡的能力。

研究设计与样本

  • 前瞻性分析308例患者共322例机械对线全膝关节置换术,在置入股骨与胫骨试模后于10°、45°、90°屈膝时比较术者判断与传感器数据。

主要发现

  • 术者判断与传感器数据相比准确率在10°、45°、90°屈膝时分别为63%、57.5%、63.8%。
  • 术者判断总体敏感度81%、特异度37.7%。
  • 术者判断特异度在10°、45°、90°分别为53.5%、34.8%、24.8%,10° vs 45° P=0.0004,10° vs 90° P<0.0001。
  • Cohen kappa系数在10°为0.29(fair agreement),45°和90°分别为0.14和0.12(poor agreement)。
  • 传感器使用对判断膝关节平衡能力无时间学习效应。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Soft tissue balance is believed to be a major determinant of improved outcomes in total knee arthroplasty (TKA). We conducted this study to assess the accuracy of surgeon-defined assessment (SDA) of knee balance compared to pressure sensor data. We also assessed for any association between experience (learning curve) and accuracy of SDA. METHODS: A total of 308 patients undergoing 322 mechanically aligned TKA were prospectively analyzed. Femoral and tibial trial implants were inserted before performing knee balancing. We compared the surgeon determination on knee balance at 10°, 45°, and 90° of flexion to sensor data at the same flexion angles. RESULTS: Accuracy of SDA was 63%, 57.5%, and 63.8% at 10°, 45°, and 90°, respectively, when compared to sensor data. SDA had an overall sensitivity of 81% and specificity of 37.7%. Capacity to determine an unbalanced knee worsened at higher knee flexion angles with SDA test specificity of 53.5%, 34.8%, and 24.8% at 10°, 45°, and 90°, respectively (P = .0004 at 10° vs 45°, P < .0001 at 10° vs 90°). Cohen's kappa coefficient was 0.29 at 10° indicating fair agreement, and 0.14 and 0.12 at 45° and 90°, respectively, indicating poor agreement. The use of sensor had no time-based learning effect on capacity to determine knee balance. CONCLUSION: SDA is a poor predictor of the true soft tissue balance when compared to sensor data, particularly in assessing whether a knee is unbalanced. In addition, increased use of sensors did not improve surgeon capacity to determine knee balance.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. MacDessi SJ, Gharaibeh MA, Harris IA, et al. How Accurately Can Soft Tissue Balance Be Determined in Total Knee Arthroplasty? J Arthroplasty. 2018. PMID: 30389257. doi:10.1016/j.arth.2018.10.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。