文献速递创伤骨科

在大鼠体内模型中用微型计算机断层扫描和生物力学测试对胫骨骨折放射愈合评分(RUST)的实验验证

Experimental Validation of the Radiographic Union Score for Tibial Fractures (RUST) Using Micro-Computed Tomography Scanning and Biomechanical Testing in an in-Vivo Rat Model.
PubMed 文献 · J Bone Joint Surg Am · 2018-01-01

研究纳入29只成年雄性大鼠,行中段截骨并聚醚醚酮板修复,在5至17周终点行X线检查并由2名骨科创伤专科医生独立评分RUST与mRUST,随后行微型CT扫描和生物力学扭转测试。结果显示RUST与mRUST的组内相关系数分别为0.89和0.86,二者与微型CT及生物力学参数存在相关性,RUST评分10分或mRUST评分15分可考虑为钢板固定骨「愈合」的阈值。

要点

  • RUST与mRUST的组内相关系数分别为0.89(95%CI:0.78至0.94)和0.86(95%CI:0.74至0.93),属「几乎完全一致」类别。
  • RUST评分10分或mRUST评分15分可考虑为钢板固定骨「愈合」的阈值,此时修复股骨分别达到对侧完整股骨失败扭矩的120%或140%。
  • RUST与mRUST均与微型CT及生物力学参数显示强统计学相关性。

核心结论

  • RUST与mRUST均与微型CT和生物力学参数显示强统计学相关性。
  • RUST评分10分或mRUST评分15分可考虑为钢板固定骨「愈合」的阈值。

研究设计与样本

  • 成年雄性大鼠(n=29)行截骨术,中段骨折间隙用聚醚醚酮板修复。
  • 在5、6、7、8、9和17周终点处死大鼠前拍摄修复股骨正侧位X线片,由2名经过专科培训的骨科创伤外科医生独立对修复股骨进行RUST和mRUST评分。
  • 随后解剖修复侧和对侧完整股骨,进行微型CT扫描和生物力学扭转测试。

主要发现

  • RUST评分范围为5至12分,mRUST评分范围为5至16分。
  • RUST的组内相关系数为0.89(95%CI:0.78至0.94),mRUST为0.86(95%CI:0.74至0.93),均属「几乎完全一致」类别。
  • Spearman秩相关系数显示RUST(RS范围0.456至0.818)和mRUST(RS范围0.519至0.862)与微型CT测量的矿化骨痂体积(BV)、总骨痂体积(TV)及BV/TV比值相关,但与骨矿物质密度(BMD)相关性较弱。
  • RUST(RS范围0.524至0.863)和mRUST(RS范围0.434至0.850)与部分生物力学特性相关。
  • RUST评分10分或mRUST评分15分时,修复股骨分别达到对侧完整股骨失败扭矩的120%或140%。

关键数值与推荐

  • RUST评分10分或mRUST评分15分可考虑为钢板固定骨「愈合」的阈值,此时修复股骨分别达到对侧完整股骨失败扭矩的120%或140%。

临床怎么用

  • RUST和mRUST评分系统为临床医生提供了经过验证、可靠且可用的工具来评估骨折愈合进展。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The Radiographic Union Score for Tibial fractures (RUST) and the modified version of the system, mRUST, are popular standards for assessing fracture-healing progress with use of radiographs. To our knowledge, this is the first study to experimentally validate the ability of RUST and mRUST to accurately assess bone-healing progression with use of both micro-computed tomography (micro-CT) scanning and biomechanical testing. METHODS: Adult male rats (n = 29) underwent osteotomy with a midshaft fracture gap repaired with use of a polyetheretherketone plate. Anteroposterior and lateral radiographs were made of the repaired femora prior to rat death at end points of 5, 6, 7, 8, 9, and 17 weeks, and 2 fellowship-trained orthopaedic trauma surgeons independently assigned RUST and mRUST scores to repaired femora. The repaired and intact contralateral femora were then dissected. Bones underwent dissection, micro-CT scanning, and biomechanical torsion testing at the end points. RESULTS: RUST scores ranged from 5 to 12 and mRUST scores ranged from 5 to 16. Intraclass correlation coefficients (ICCs) were 0.89 (95% confidence interval [CI]: 0.78 to 0.94) for RUST and 0.86 (95% CI: 0.74 to 0.93) for mRUST, which fall within the "almost perfect agreement" category for ICCs. Spearman rank correlation coefficients (RS) showed correlation of RUST (RS range, 0.456 to 0.818) and mRUST (RS range, 0.519 to 0.862) with micro-CT measurements of mineralized callus volume (BV), total callus volume (TV), and BV/TV ratio, but less so with bone mineral density (BMD). Additionally, RUST (RS range, 0.524 to 0.863) and mRUST (RS range, 0.434 to 0.850) were correlated with some biomechanical properties. A RUST score of 10 or an mRUST score of 15 may be considered the threshold above which a plated bone is "healed" because, at these scores, 120% or 140% of failure torque, respectively, was achieved by the repaired femora as compared with the intact contralateral femora. CONCLUSIONS: RUST and mRUST both show strong statistical correlations with micro-CT and biomechanical parameters. CLINICAL RELEVANCE: RUST and mRUST scoring systems provide clinicians with validated, reliable, and available tools to assess the progress of fracture-healing.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Fiset S, Godbout C, Crookshank MC, et al. Experimental Validation of the Radiographic Union Score for Tibial Fractures (RUST) Using Micro-Computed Tomography Scanning and Biomechanical Testing in an in-Vivo Rat Model. J Bone Joint Surg Am. 2018. PMID: 30399082. doi:10.2106/JBJS.18.00035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。