文献速递创伤骨科

使用95°角钢板挽救长期双膦酸盐治疗相关非典型股骨转子下骨折内固定失败

Salvage of failed osteosynthesis for an atypical subtrochanteric femoral fracture associated with long-term bisphosphonate treatment using a 95° angled blade plate.
PubMed 文献 · Bone Joint J · 2018-01-01

本研究评估95°角钢板用于长期双膦酸盐相关非典型股骨转子下骨折内固定失败后的挽救手术效果,并与非双膦酸盐相关典型转子下骨折内固定失败病例比较。非典型组14例(均为女性,平均年龄67.8岁)中12例(85.7%)平均8.4个月愈合,典型组21例中18例(85.7%)平均7.9个月愈合;两组末次随访Harris髋关节评分无显著差异(83.1分 vs 86.8分,p=0.522)。作者认为95°角钢板是非典型转子下骨折不愈合的有效固定方式,愈合率高且功能改善,与双膦酸盐无关骨折相当。

要点

  • 非典型组14例中12例(85.7%)平均8.4个月愈合,典型组21例中18例(85.7%)平均7.9个月愈合。
  • 两组末次随访平均Harris髋关节评分无显著差异(83.1分 vs 86.8分,p=0.522)。
  • Sanders功能评级优良率非典型组78.6%,典型组81.0%。

核心结论

  • 95°角钢板被证明是非典型股骨转子下骨折不愈合的有效固定方式,愈合率高且功能改善,与双膦酸盐无关骨折后相当。

研究设计与样本

  • 2008年10月至2016年7月,14例长期双膦酸盐相关非典型股骨转子下骨折内固定失败患者采用角钢板治疗(非典型组),平均年龄67.8岁(60至74岁),均为女性;同期21例典型股骨转子下骨折内固定失败患者采用角钢板再稳定(典型组)。

主要发现

  • 非典型组12例(85.7%)平均8.4个月(4至12个月)愈合,平均随访31.2个月(12至92个月)。
  • 非典型组1例钢板断裂需更长钢板及支撑植骨进一步稳定,另1例固定失败伴骨折部位内翻成角拒绝进一步手术。
  • 典型组18例(85.7%)平均7.9个月(4至12个月)愈合。
  • 两组末次随访平均Harris髋关节评分无显著差异(非典型组83.1分 vs 典型组86.8分;p=0.522)。
  • Sanders功能评级优良率非典型组78.6%,典型组81.0%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to evaluate the outcomes of a salvage procedure using a 95° angled blade plate for failed osteosynthesis of atypical subtrochanteric femoral fractures associated with the long-term use of bisphosphonates. These were compared with those for failed osteosynthesis of subtrochanteric fractures not associated with bisphosphonate treatment. PATIENTS AND METHODS: Between October 2008 and July 2016, 14 patients with failed osteosynthesis of an atypical subtrochanteric femoral fracture were treated with a blade plate (atypical group). Their mean age was 67.8 years (60 to 74); all were female. During the same period, 21 patients with failed osteosynthesis of a typical subtrochanteric fracture underwent restabilization using a blade plate (typical group). Outcome variables included the time of union, postoperative complications, Harris Hip Score, and Sanders functional rating scale. RESULTS: In the atypical group, union was achieved in 12 patients (85.7%) at a mean of 8.4 months (4 to 12). The mean follow-up was 31.2 months (12 to 92) The plate broke in one patient requiring further stabilization with a longer plate and strut-allograft. Another patient with failure of fixation and varus angulation at the fracture site declined further surgery. In the typical group, union was achieved in 18 patients (85.7%) at a mean of 7.9 months (4 to 12). There was no difference in the mean Harris Hip Score between the two groups (83.1 points vs 86.8 points; p = 0.522) at the time of final follow-up. Sanders functional rating scores were good or excellent in 78.6% of the atypical group and in 81.0% of the typical group. CONCLUSION: The 95° angled blade plate was shown to be an effective fixation modality for nonunion of atypical subtrochanteric fractures with a high rate of union and functional improvement, comparable to those after fractures not associated with bisphosphonate treatment. Cite this article: Bone Joint J 2018;100-B:1511-17.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Kim SM, Rhyu KH, Lim SJ, et al. Salvage of failed osteosynthesis for an atypical subtrochanteric femoral fracture associated with long-term bisphosphonate treatment using a 95° angled blade plate. Bone Joint J. 2018. PMID: 30418051. doi:10.1302/0301-620X.100B11.BJJ-2018-0306.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。