脊柱内固定术前评估骨质量的Hounsfield单位值测量技术与效用:当前文献综述
本系统综述评估CT衰减Hounsfield单位(HU)评估骨质量的临床效用。HU测量与腰椎椎间融合、后外侧融合、 cage沉降、邻近节段骨折、椎弓根螺钉松动及 incidental durotomy 风险相关,且信度优异。作者认为HU测量简单快速,应在所有已有CT扫描的患者中进行,但需更多前瞻性研究验证。
要点
- HU测量与腰椎椎间融合成功(133.7 vs 107.3 HU)及后外侧融合(167 vs 139.8 HU)相关。
- HU值在并发症组更低:cage沉降(112.4 vs 140.2 HU)、邻近节段骨折(145.6 vs 199.4 HU)、螺钉松动(116.4 vs 132.7 HU 和 99.1 vs 141.2 HU)、硬膜撕裂风险(149.2 vs 177.0 HU)。
- L1 HU阈值110 HU检测骨质疏松、135 HU检测骨量减少的Specificity均为90%。
核心结论
- HU值测量是一种简单快速的骨质量评估技术,应在所有已有CT扫描的患者中进行。
- HU测量具有优异的组内和组间信度,可在轴位或矢状位图像上进行。
- 在严重退行性疾病患者中,HU值应给予更多信任。
- 需要额外的高质量前瞻性研究比较HU和DEXA值与患者结局,以验证CT测量在术前评估中的作用。
研究设计与样本
- 系统综述,检索MEDLINE、Cochrane Library和EMBASE中HU与骨密度及脊柱手术结局相关的研究。
主要发现
- HU测量与腰椎椎间融合成功相关(133.7 vs 107.3 HU)。
- HU测量与后外侧融合成功相关(167 vs 139.8 HU)。
- HU测量与cage沉降相关(112.4 vs 140.2 HU)。
- HU测量与邻近节段骨折相关(145.6 vs 199.4 HU)。
- HU测量与椎弓根螺钉松动相关(116.4 vs 132.7 HU)和(99.1 vs 141.2 HU),与incidental durotomy风险相关(149.2 vs 177.0 HU)。
关键数值与推荐
- 组内和组间信度系数分别为0.964和0.975。
- 非退行性疾病患者中HU值与骨密度的相关性r=0.52,退行性疾病患者中r=0.18。
- L1 HU阈值110 HU检测骨质疏松、135 HU检测骨量减少的Specificity均为90%。
临床怎么用
- 作者认为HU值测量是一种简单快速的骨质量评估技术,应在所有已有CT扫描的患者中进行。
- 作者认为HU测量可在轴位或矢状位图像上进行。
- 作者认为在严重退行性疾病患者中,HU值应给予更多信任。
局限性
- 需要额外的高质量前瞻性研究比较HU和DEXA值与患者结局,以验证CT测量在术前评估中的作用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: A systematic review. OBJECTIVE: The aim of this study was to evaluate the clinical utility of assessing bone quality using computed tomography (CT) attenuation in Hounsfield units (HU). SUMMARY OF BACKGROUND DATA: Assessing bone quality before spine instrumentation is an essential step of preoperative planning. Dual energy x-ray absorptiometry (DEXA) has been the gold standard for assessing bone mineral density (BMD); however, DEXA can result in spuriously elevated BMD measurements in patients with degenerative disease, compression fractures, and/or vascular calcifications. Measuring vertebral HU values has been proposed as an alternate method of assessing BMD and bone quality. METHODS: We searched MEDLINE, Cochrane Library, and EMBASE for studies correlating HU to BMD and to spine surgery outcomes. RESULTS: HU measurements correlate with success of lumbar interbody fusion (133.7 vs. 107.3 HU) and posterolateral fusion (167 vs. 139.8 HU), cage subsidence (112.4 vs. 140.2 HU), adjacent segment fractures (145.6 vs. 199.4 HU), pedicle screw loosening (116.4 vs. 132.7 HU) and (99.1 vs. 141.2 HU), and risk of incidental durotomy (149.2 vs. 177.0 HU). Intra and inter-rater reliability coefficients are 0.964 and 0.975. The correlation between HU values and BMD in nondegenerative patients is r = 0.52 compared with HU versus BMD in degenerative patients r = 0.18. CONCLUSION: HU value measurement is a simple and rapid technique to assess bone quality that should be performed in all patients with pre-existing CT scans. HU measurement has excellent inter and intra-rater reliability and can be performed on axial or sagittal images. L1 HU threshold values of 110 HU for detecting osteoporosis, and 135 HU for detecting osteopenia are 90% specific. In patients with significant degenerative disease, HU values should be given more credence. Additional high-quality prospective studies comparing HU and DEXA values to patient outcomes are necessary to validate the role of CT measurements in preoperative evaluation. LEVEL OF EVIDENCE: 4.
引用
- Zaidi Q, Danisa OA, Cheng W, et al. Measurement Techniques and Utility of Hounsfield Unit Values for Assessment of Bone Quality Prior to Spinal Instrumentation: A Review of Current Literature. Spine (Phila Pa 1976). 2019. PMID: 30063528. doi:10.1097/BRS.0000000000002813
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。