侧卧位骨盆方向的可变性:外部对准导引器是否可信?
该研究分析了一位术者在侧卧位下连续实施的248例全髋关节置换术(THA)的术前站立位与术中骨盆正位X线片,评估骨盆倾斜与旋转的变异性。结果显示,仅62.1%的病例术中体位在术前倾斜与轴向旋转10°以内,骨盆位置不良总体发生率为38%。结论认为侧卧位骨盆方向变异性大,应使用解剖标志引导髋臼假体定位。
要点
- 侧卧位THA中骨盆倾斜与旋转在术前与术中X线片间常出现差异,骨盆位置不良总体发生率为38%。
- 骨盆倾斜在188例(76%)中位置合适,旋转在202例(81%)中位置合适,但仅154例(62.1%)两者均在10°以内。
- 作者认为应使用解剖标志引导髋臼假体定位。
核心结论
- 侧卧位骨盆方向存在广泛变异,术前与术中骨盆正位X线片间骨盆倾斜和旋转常出现差异。
- 作者认为应使用解剖标志引导髋臼假体定位。
研究设计与样本
- 分析一位术者在侧卧位下连续实施的248例全髋关节置换术(THA)的术前站立位与术中骨盆正位X线片,评估骨盆倾斜与旋转。
- 术中位置合适定义为术前与术中X线片间倾斜或旋转变化小于10°。
主要发现
- 骨盆倾斜方面,术中位置合适188例(76%),倾斜差异10°-20°者43例(17.5%),大于20°者16例(6.5%)。
- 骨盆旋转方面,术中位置合适202例(81%),旋转差异10°-20°者38例(15.4%),大于20°者7例(2.8%)。
- 248例中仅154例(62.1%)术中位置在术前倾斜与轴向旋转10°以内。
- 骨盆位置不良总体发生率为38%。
临床怎么用
- 作者认为应使用解剖标志引导髋臼假体定位。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The position of the acetabular component in total hip arthroplasty (THA) is critical for success. However, this remains the most variable aspect of the surgery. We hypothesized that there is wide variation in pelvic orientation in the lateral decubitus position. We sought to determine the variability in pelvic positioning and the frequency of pelvic malposition during THA in lateral decubitus with regard to pelvic tilt and pelvic rotation. METHODS: We analyzed preoperative standing and intraoperative anteroposterior pelvis X-rays in 248 consecutive THAs performed in lateral decubitus by one surgeon. Pelvic tilt and rotation were determined for preoperative and intraoperative X-rays. Proper intraoperative positioning was defined as less than 10° change in tilt or rotation between preoperative and intraoperative X-rays. RESULTS: With regard to pelvic tilt, the intraoperative position was proper in 188 (76%) cases. There was a pelvic tilt discrepancy of 10°-20° in 43 (17.5%) cases and greater than 20° in 16 (6.5%) patients. With regard to pelvic rotation, the intraoperative position was proper in 202 (81%) cases. There was a pelvic rotation discrepancy of 10°-20° in 38 (15.4%) cases and greater than 20° in 7 (2.8%) cases. In 248 cases, only 154 (62.1%) had intraoperative positioning within 10° of preoperative tilt and axial rotation. Pelvic malposition occurred in 38% of cases overall. CONCLUSION: There is wide variation in pelvic orientation in lateral decubitus and frequent discrepancy in pelvic tilt and rotation between preoperative and intraoperative anteroposterior X-rays. Anatomic landmarks should be used to guide acetabular component positioning. LEVEL OF EVIDENCE III: Diagnostic.
引用
- Otero JE, Fehring KA, Martin JR, et al. Variability of Pelvic Orientation in the Lateral Decubitus Position: Are External Alignment Guides Trustworthy? J Arthroplasty. 2018. PMID: 30150153. doi:10.1016/j.arth.2018.07.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。