髋臼重建中结构性同种异体骨的整合与重塑:13例骨盆取回标本的多尺度微形态学分析
研究对13例翻修术后取回的髋臼标本采用接触放射摄影、高分辨率外周定量CT、未脱钙组织学和定量背散射电子成像进行多尺度分析,发现10例界面100%直接接触并重叠,同种异体骨小梁结构完整且矿化高于宿主骨,平均当前重叠2.3±1.0 mm、总长入7.2±2.3 mm;缺乏完全整合未导致至术后22年植骨塌陷。
要点
- 13例中10例界面100%直接接触并重叠,3例直接接触占25%至80%。
- 同种异体骨小梁结构完整,矿化显著高于宿主骨。
- 平均当前重叠2.3±1.0 mm,总长入平均7.2±2.3 mm。
核心结论
- 沿大部分界面出现骨重塑及宿主骨与同种异体骨的相互连接,导致同种异体骨充分整合。
- 移植物缺乏完全整合未导致翻修术后至22年植骨塌陷。
研究设计与样本
- 取回13例髋臼尸检标本,采用接触放射摄影、高分辨率外周定量CT、未脱钙标本组织学分析和定量背散射电子成像的分层影像技术分析同种异体骨整合特性。
- 评估当前同种异体骨与宿主骨边界间距(当前重叠)及原始同种异体骨与宿主骨边界间距(总长入)。
主要发现
- 13例中10例整个界面(100%)表现为同种异体骨与宿主骨直接接触并额外重叠,其余3例直接接触占界面的25%至80%。
- 同种异体骨显示完整骨小梁结构,矿化显著高于宿主骨。
- 平均当前重叠为2.3±1.0 mm,最大值为5.3±2.4 mm;总长入达平均7.2±2.3 mm(最大值10.5±4.0 mm)。
- 同种异体骨在位时间及宿主骨与同种异体骨接触程度均与当前重叠不相关,在位时间与总长入不相关。
临床怎么用
- 作者认为本研究首次对成功植入的结构性同种异体骨进行系统多尺度评估,为其在翻修全髋关节置换术中的临床使用提供科学基础。
局限性
- 既往研究限于临床数据或纳入病例极少,同种异体骨随时间整合程度仍不清楚。
- 本研究结论基于13例取回标本的多尺度分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Total hip arthroplasty (THA) is frequently accompanied by acetabular bone loss, which constitutes a major challenge in revision procedures. Structural allografts can be implanted to restore a stable osseous foundation for the acetabular prosthesis. As previous studies were limited to clinical data or included very few cases, the extent to which the graft bone is incorporated over time has remained unclear. METHODS: Thirteen acetabula were retrieved post mortem, and the incorporation properties of the bone allografts were analyzed using a hierarchical approach of imaging techniques including contact radiography, high-resolution peripheral quantitative computed tomography (HR-pQCT), histological analysis of undecalcified specimens, and quantitative backscattered electron imaging (qBEI). The distance between the current allograft bone and host bone borders (i.e., current overlap) as well as the distance between the original allograft bone and host bone borders (i.e., total ingrowth) were assessed. RESULTS: In 10 of 13 cases, the complete interface (100%) was characterized by direct contact and additional overlap of the allograft bone and host bone, while the remaining 3 cases demonstrated direct contact along 25% to 80% of the interface. The allograft bone showed an intact trabecular structure and significantly higher mineralization compared with the host bone. The mean current overlap (and standard deviation) was 2.3 ± 1.0 mm, with a maximum of 5.3 ± 2.4 mm. Importantly, the total ingrowth reached much further, to a mean of 7.2 ± 2.3 mm (maximum, 10.5 ± 4.0 mm). Neither the time that the allograft was in situ nor the degree of contact between the host and allograft bone correlated with the current overlap and the time in situ did not correlate with total ingrowth. CONCLUSIONS: This study showed bone remodeling with subsequent interconnection of the host and allograft bone along the majority of the interface, leading to adequate incorporation of the allograft. The lack of complete incorporation of the graft did not lead to graft collapse up to 22 years after revision surgery. CLINICAL RELEVANCE: Our study provides the first systematic multiscale evaluation of successfully implanted structural allografts and forms the scientific basis for their clinical use in revision THA.
引用
- Butscheidt S, Moritz M, Gehrke T, et al. Incorporation and Remodeling of Structural Allografts in Acetabular Reconstruction: Multiscale, Micro-Morphological Analysis of 13 Pelvic Explants. J Bone Joint Surg Am. 2018. PMID: 30106822. doi:10.2106/JBJS.17.01636
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。