文献速递关节外科创伤骨科

氧化铝陶瓷非铰链型骨水泥固定全肘关节置换术治疗类风湿关节炎患者的中期结果

Mid-term results of alumina ceramic unlinked total elbow arthroplasty with cement fixation for patients with rheumatoid arthritis.
PubMed 文献 · Bone Joint J · 2018-01-01

回顾性分析75例类风湿关节炎患者87个肘关节,2003年8月至2012年12月行骨水泥固定J-氧化铝陶瓷肘(JACE)非铰链型全肘关节置换术,随访率96%,平均随访9年。Mayo肘关节性能指数(MEPI)从术前平均40分显著改善至末次随访95分(p<0.0001)。并发症10肘(11%),以任何翻修手术为终点14年生存率93%(95%CI 83.9至96.6),以取出假体的翻修为终点为99%(95%CI 91.9至99.8)。

要点

  • 骨水泥固定JACE全肘关节置换术后MEPI从术前平均40分改善至末次随访95分(p<0.0001)。
  • 10肘(11%)出现并发症,1肘因深部感染行取出假体的翻修术。
  • 以任何翻修为终点14年生存率93%(95%CI 83.9至96.6),以取出假体翻修为终点99%(95%CI 91.9至99.8)。

核心结论

  • 在适应证合适的情况下,骨水泥固定JACE全肘关节置换术治疗类风湿关节炎患者的中期临床性能可靠,与其他成熟全肘关节置换术相当。

研究设计与样本

  • 回顾性综述2003年8月至2012年12月期间75例类风湿关节炎患者(72女3男,平均年龄62岁,范围35至79岁)的87个肘关节,均行骨水泥固定JACE非铰链型全肘关节置换术,随访率96%,平均随访9年(范围2至14年)。
  • 术前术后临床状况采用Mayo肘关节性能指数(MEPI,0至100分)评估。
  • 影像学松动定义为假体周围完全环周、进展性>1 mm的透亮线。

主要发现

  • MEPI评分从术前平均40分(范围10至75)显著改善至末次随访平均95分(范围30至100)(p<0.0001)。
  • 10肘(10例患者,11%)出现并发症:2肘术中肱骨骨折经固定愈合,1肘术后尺骨鹰嘴骨折经保守治疗愈合,1肘桡神经病变缓解。
  • 1肘因脱位、3肘因尺神经病变、1肘因术后肱骨骨折需再次手术;1肘因深部感染行取出假体的翻修术。
  • 无影像学证据显示假体周围松动。
  • Kaplan-Meier分析:以任何翻修手术为终点14年生存率93%(95%CI 83.9至96.6),以取出假体的翻修为终点99%(95%CI 91.9至99.8)。

临床怎么用

  • 原文结论认为在适应证合适的情况下,骨水泥固定JACE全肘关节置换术治疗类风湿关节炎患者的中期临床性能可靠,与其他成熟全肘关节置换术相当。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to report the mid-term clinical outcome of cemented unlinked J-alumina ceramic elbow (JACE) arthroplasties when used in patients with rheumatoid arthritis (RA). PATIENTS AND METHODS: We retrospectively reviewed 87 elbows, in 75 patients with RA, which was replaced using a cemented JACE total elbow arthroplasty (TEA) between August 2003 and December 2012, with a follow-up of 96%. There were 72 women and three men, with a mean age of 62 years (35 to 79). The mean follow-up was nine years (2 to 14). The clinical condition of each elbow before and after surgery was assessed using the Mayo Elbow Performance Index (MEPI, 0 to 100 points). Radiographic loosening was defined as a progressive radiolucent line of >1 mm that was completely circumferential around the prosthesis. RESULTS: The mean MEPI scores significantly improved from 40 (10 to 75) points preoperatively to 95 (30 to 100) points at final follow-up (p < 0.0001). Complications were noted in ten elbows (ten patients; 11%). Two had an intraoperative humeral fracture which was treated by fixation and united. One had a postoperative fracture of the olecranon which united with conservative treatment and one had a radial neuropathy which resolved. Further surgery was required for one with a dislocation, three with an ulnar neuropathy and one with a postoperative humeral fracture. Revision with removal of the components was performed in one elbow due to deep infection. There was no radiographic evidence of loosening around the components. With any revision surgery or revision with implant removal as the endpoint, the rates of survival up to 14 years were 93% (95% confidence interval (CI), 83.9 to 96.6) and 99% (95% CI 91.9 to 99.8), respectively, as determined by Kaplan-Meier analysis. CONCLUSION: With the appropriate indications, the mid-term clinical performance of the cemented JACE TEA is reliable and comparable to other established TEAs in the management of the elbow in patients with RA. Cite this article: Bone Joint J 2018;100-B:1066-73.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Nishida K, Hashizume K, Nasu Y, et al. Mid-term results of alumina ceramic unlinked total elbow arthroplasty with cement fixation for patients with rheumatoid arthritis. Bone Joint J. 2018. PMID: 30062938. doi:10.1302/0301-620X.100B8.BJJ-2017-1451.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。