发育不良型Walch C型肩胛盂的特征分析
这项解剖学研究分析了29例发育不良型肩胛盂的CT形态,测量后倾角、倾斜角、高度、宽度、曲率半径、表面积、深度、肱骨头半脱位及Goutallier脂肪浸润分级。C型肩胛盂占转诊肩关节的1.8%,平均后倾37°,典型表现为单凹后倾形态、后下缘及肩胛颈骨缺损和深度减小。
要点
- C型肩胛盂平均后倾37°、倾斜3°、高度46 mm、宽度30 mm,典型呈单凹后倾形态。
- 后盂缘呈圆形或「懒J」形,18肩(62%)肩胛颈骨缺损,平均肱骨头后脱位90%。
- 发育不良程度:轻度4肩、中度14肩、重度11肩;Goutallier分级<2者25肩(86%)。
核心结论
- 发育不良型C型肩胛盂特征为单凹后倾形态、后下缘及肩胛颈骨缺损和深度减小,这些发现有助于手术规划和为这类患者开发假体组件。
研究设计与样本
- 解剖学研究,分析29例发育不良型肩胛盂肩关节,采用CT测量后倾角、倾斜角、高度、宽度、曲率半径、表面积、深度、肱骨头半脱位及Goutallier脂肪浸润分级。
主要发现
- C型肩胛盂占转诊至三级中心的肩关节的1.8%。
- 肩胛盂平均后倾37°、倾斜3°、高度46 mm、宽度30 mm、曲率半径37°、表面积1284 mm3、深度16 mm。
- 平均肱骨头后脱位90%;Goutallier分级<2者25肩(86%)。
- 发育不良程度轻度4肩、中度14肩、重度11肩;后盂缘典型呈圆形或「懒J」形;肩胛颈骨缺损18肩(62%)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The Walch Type C dysplastic glenoid is characterized by excessive retroversion. This anatomical study describes its morphology. PATIENTS AND METHODS: A total of 29 shoulders with a dysplastic glenoid were analyzed. CT was used to measure retroversion, inclination, height, width, radius-of-curvature, surface area, depth, subluxation of the humeral head and the Goutallier classification of fatty infiltration. The severity of dysplasia and deficiency of the posterior rim of the glenoid were recorded. RESULTS: A type C glenoid occurred in 1.8% of shoulders referred to our tertiary centres. The mean retroversion, inclination, height, width, radius-of-curvature, surface area, and depth of the glenoid were 37°, 3°, 46 mm, 30 mm, 37°, 1284 mm3, and 16 mm, respectively. The mean posterior subluxation was 90%. The Goutallier class was < 2 in 25 shoulders (86%). Glenoid dysplasia was mild in four, moderate in 14, and severe in 11 shoulders. The typical appearance of the posterior glenoid rim had a rounded or 'lazy J' morphology. The glenoid neck was deficient in 18 shoulders (62%). CONCLUSION: A dysplastic Type C glenoid characteristically has a uniconcave retroverted morphology, a deficient posteroinferior rim and scapular neck, and a reduced depth. These findings help to define the unique anatomical variations and may aid the planning of surgery and the development of components for these patients. Cite this article: Bone Joint J 2018;100-B:1074-9.
引用
- Paul R, Knowles N, Chaoui J, et al. Characterization of the dysplastic Walch type C glenoid. Bone Joint J. 2018. PMID: 30062949. doi:10.1302/0301-620X.100B8.BJJ-2018-0116.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。