文献速递关节外科

全髋关节置换术后新型手术数据采集系统的验证

Validation of a Novel Surgical Data Capturing System Following Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2018-07-17

本研究在单中心2016年1月至4月由15名外科医生完成的100例初次全髋关节置换术和100例翻修全髋关节置换术中,前瞻性将OrthoMiDaS(骨科最小数据集)诊疗事件(OME)数据库与传统手术记录进行对比。结果显示OME数据库在41%(39/96)的变量上完成率显著更高,54%(52/96)的变量匹配比例>0.90;结论认为OME是一种高效、用户友好、全面且准确的数据记录工具,可能成为未来骨科研究的有价值工具。

要点

  • OME数据库在41%(39/96)的变量上完成率显著高于传统手术记录。
  • 54%(52/96)的变量在手术记录与OME数据间匹配比例>0.90,79%(76/96)>0.80。
  • 25%(24/96)的变量一致性几乎完美,29%(28/96)为实质性一致。

核心结论

  • OME数据采集系统是记录全髋关节置换术手术细节的高效工具,用户友好、全面且准确,可能成为未来骨科研究的有价值工具。

研究设计与样本

  • 本研究纳入2016年1月至4月单中心15名外科医生完成的最初100例初次全髋关节置换术和100例翻修全髋关节置换术的数据,外科医生术后前瞻性将手术细节录入OME。
  • 比较OME数据库与手术记录的完成率和一致性,完成率采用McNemar检验(带连续性校正),一致性采用Cohen kappa(κ)和一致性相关系数分析。

主要发现

  • OME数据库在41%(39/96)的变量上完成率显著更高。
  • 手术记录与OME数据匹配的数据点比例中,54%(52/96)的变量匹配比例>0.90,79%(76/96)的变量匹配比例>0.80。
  • 一致性方面,25%(24/96)的变量几乎完美一致,29%(28/96)为实质性一致,14%(13/96)为中度一致。
  • 仅4%(4/96)的变量为一般一致,8%(8/96)为轻微一致,6%(6/96)为差一致。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The OrthoMiDaS (Orthopedic Minimal Data Set) Episode of Care (OME) database was developed in an effort to advance orthopedic outcome measurements on a national scale. This study was designed to evaluate if the OME data capture system would increase the quality of data collected in the context of primary and revision total hip arthroplasty (THA) compared to conventional operative notes. METHODS: This study includes data from the first 100 primary THAs and 100 revision THAs performed by 15 surgeons at a single institution from January through April 2016. Surgeons prospectively entered procedural details into OME following surgery. The OME database and operative notes were compared to evaluate completion rates and agreement. Completion rates were compared using McNemar's test (with continuity correction), while agreement was analyzed using Cohen's kappa (κ) and concordance correlation coefficient. RESULTS: The OME database had significantly higher completion rates for 41% (39/96) of the variables. Proportion of data points that matched between the operative notes and OME data revealed that 54% (52/96) had a proportion agreement >0.90, and 79% (76/96) had a proportion agreement >0.80. In regard to measured agreement, 25% (24/96) of variables had almost perfect agreement, 29% (28/96) had substantial agreement, and 14% (13/96) had moderate agreement. Only 4% (4/96) had fair agreement, 8% (8/96) had slight agreement, and 6% (6/96) had poor agreement. CONCLUSION: The OME data capture system is an efficient tool to document procedural details following THA. The system is user-friendly, comprehensive, and accurate. It has the potential to be a valuable tool for future orthopedic research.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Curtis GL, Tariq MB, Brigati DP, et al. Validation of a Novel Surgical Data Capturing System Following Total Hip Arthroplasty. J Arthroplasty. 2018. PMID: 30093265. doi:10.1016/j.arth.2018.07.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。