聚乙烯髋关节表面置换术治疗严重髋臼功能不全性关节炎
2001至2011年间,232例因严重髋臼发育不良继发晚期关节炎的Crowe II或III型患者接受聚乙烯表面置换髋关节成形术,平均随访10年假体生存率为96%(95%CI 89-98),8髋(3.5%)转为全髋关节置换,功能评分显著改善。
要点
- 聚乙烯双件式髋臼表面置换治疗Crowe II/III型严重髋臼发育不良,平均10年假体生存率96%(95%CI 89-98)。
- 8髋(3.5%)因髋臼松动(1)、股骨颈骨折(2)、股骨坏死(2)、感染(2)或持续疼痛(1)转为全髋关节置换。
- 术后2年Harris髋关节评分从术前均值55改善至97,UCLA活动评分从5改善至8。
核心结论
- 使用双件式聚乙烯髋臼组件对严重发育不良行髋关节表面置换,在中期随访中获得了优异的功能和假体生存率,并发症率低。
研究设计与样本
- 2001年至2011年间连续实施232例聚乙烯表面置换髋关节成形术,纳入201例因发育不良导致严重髋臼功能不全的晚期关节炎患者,所有患者均为Crowe II或III型,手术时平均年龄43岁。
主要发现
- 平均随访10年期间,8髋(3.5%)转为全髋关节置换,原因为髋臼松动(1例)、股骨颈骨折(2例)、股骨坏死(2例)、感染(2例)或持续疼痛(1例),假体平均生存率为96%(95%CI 89-98)。
- 无待定翻修,无脱位。
- 术后2年,Harris髋关节评分从术前均值55改善至97,UCLA活动评分从5改善至8。
关键数值与推荐
- 植入带穹顶螺钉的非骨水泥双件式髋臼表面置换壳和高交联聚乙烯内衬,以提供可靠固定、早期负重和稳定髋关节,未使用附加结构性植骨和/或内固定。
- 股骨侧使用骨水泥型或非骨水泥型表面置换假体。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Hip dysplasia is the leading cause of hip arthritis in young adults. These patients often participate in active lifestyles that require a full and stable range of motion. METHODS: Between 2001 and 2011, 232 consecutive polyethylene resurfacing arthroplasties were performed in 201 patients with advanced arthritis from severe acetabular insufficiency due to dysplasia. All patients had Crowe II or III disease. Their mean age at surgery was 43 years. A 2-piece cementless acetabular resurfacing shell with dome screws and a highly cross-linked polyethylene liner were implanted to provide secure fixation, early weight bearing, and a stable hip. Additional structural bone grafts and/or fixation were not used. A cemented or cementless resurfacing prosthesis was used on the femur. RESULTS: During a mean follow-up of 10 years, 8 hips (3.5%) were converted to a total hip arthroplasty due to acetabular loosening (1), femoral neck fracture (2), femoral osteonecrosis (2), infection (2), or persistent pain (1), resulting in a mean survival of the resurfacing prostheses of 96% (95% confidence interval 89-98). There were no pending revisions and no dislocations. At 2 years postoperative, Harris Hip Scores improved from a preoperative mean of 55 to 97 and University of California Los Angeles activity scores improved from 5 to 8. CONCLUSION: Hip resurfacing using a 2-piece polyethylene acetabular component for advanced dysplasia has resulted in excellent function and implant survivorship with a low rate of complications at mid-term follow-up.
引用
- Pritchett JW. Polyethylene Hip Resurfacing to Treat Arthritis and Severe Acetabular Insufficiency. J Arthroplasty. 2018. PMID: 30131198. doi:10.1016/j.arth.2018.07.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。