文献速递创伤骨科关节外科

骨水泥与非骨水泥假体治疗移位股骨颈骨折的随机对照试验:四年随访

A randomized controlled trial of cemented versus cementless arthroplasty in patients with a displaced femoral neck fracture: a four-year follow-up.
PubMed 文献 · Bone Joint J · 2018-01-01

这项随机对照试验四年随访纳入141例移位股骨颈骨折患者,比较骨水泥(n=67)与非骨水泥(n=74)股骨柄在半髋或全髋置换中的功能与影像学结局。早期骨水泥组功能评分更优,但至48个月时差异不再有统计学意义;非骨水泥组因假体周围骨折再次手术5例(6.8%),骨水泥组2例(3%),原文报告该差异有统计学意义(p=0.4)。作者认为非骨水泥组短期功能结局较差,其发现不支持在这类老年患者中常规使用非骨水泥柄。

要点

  • 48个月时骨水泥组与非骨水泥组功能结局无统计学显著差异。
  • 非骨水泥组5例(6.8%)、骨水泥组2例(3%)因假体周围骨折再次手术,原文报告p=0.4。
  • 术后1至4年两组均无因不稳定或感染再次手术者。

核心结论

  • 移位股骨颈骨折患者使用骨水泥或非骨水泥股骨柄行关节置换,术后四年功能良好且并发症少。
  • 由于非骨水泥组短期功能结局较差,作者认为其发现不支持在这类老年患者中常规使用非骨水泥柄。

研究设计与样本

  • 随机对照研究的四年随访,纳入141例因移位股骨颈骨折接受手术的患者。
  • 患者随机接受骨水泥股骨柄(n=67)或非骨水泥股骨柄(n=74),手术方式为半髋置换(n=83)或全髋置换(n=58)。

主要发现

  • 采用Harris髋关节评分、短版肌肉骨骼功能评估问卷和EuroQol-5D评估,早期功能结局骨水泥组更优,随时间推移差异减弱,48个月时无统计学显著差异。
  • 骨水泥组2例(3%)、非骨水泥组5例(6.8%)因假体周围骨折再次手术,原文报告该差异有统计学意义(p=0.4)。
  • 术后1至4年无患者因不稳定或感染再次手术。
  • 两组死亡率和影像学结局相似。

关键数值与推荐

  • 骨水泥组因假体周围骨折再次手术2例(3%),非骨水泥组5例(6.8%),原文报告p=0.4。
  • 48个月时Harris髋关节评分、短版肌肉骨骼功能评估问卷和EuroQol-5D评分两组间无统计学显著差异。

临床怎么用

  • 作者认为,由于非骨水泥组短期功能结局较差,其发现不支持对这类老年移位股骨颈骨折患者常规使用非骨水泥股骨柄。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to compare the functional and radiological outcomes in patients with a displaced fracture of the hip who were treated with a cemented or a cementless femoral stem. PATIENTS AND METHODS: A four-year follow-up of a randomized controlled study included 141 patients who underwent surgery for a displaced femoral neck fracture. Patients were randomized to receive either a cemented (n = 67) or a cementless (n = 74) stem at hemiarthroplasty (HA; n = 83) or total hip arthroplasty (THA; n = 58). RESULTS: Early differences in functional outcome, assessed using the Harris Hip Score, the Short Musculoskeletal Functional Assessment score and EuroQol-5D, with better results in cemented group, deteriorated over time and there were no statistically significant differences at 48 months. Two (3%) patients in the cemented group and five (6.8%) in the cementless group underwent further surgery for a periprosthetic fracture. This difference was statistically significant (p = 0.4). No patient underwent further surgery for instability or infection between one and four years postoperatively. The mortality and the radiological outcomes were similar in both groups. CONCLUSION: Patients with a displaced femoral neck fracture treated with an arthroplasty using a cemented or cementless stem had good function and few complications up to four years postoperatively. However, due to the poor short-term functional outcomes in the cementless group, the findings do not support their routine use in the treatment of these elderly patients. Cite this article: Bone Joint J 2018;100-B:1087-93.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Barenius B, Inngul C, Alagic Z, et al. A randomized controlled trial of cemented versus cementless arthroplasty in patients with a displaced femoral neck fracture: a four-year follow-up. Bone Joint J. 2018. PMID: 30062941. doi:10.1302/0301-620X.100B8.BJJ-2017-1593.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。