文献速递运动医学关节外科

肩袖部分层撕裂中未撕裂关节侧肌腱的完整性:撕裂层与未撕裂层凋亡活性的比较研究

Integrity of the Untorn Articular-Sided Tendon in Bursal-Sided Partial-Thickness Rotator Cuff Tear: A Comparative Study of Apoptotic Activity in Torn and Untorn Layers.
PubMed 文献 · Am J Sports Med · 2018-07-05

该对照实验室研究比较了20例肩袖部分层撕裂患者撕裂滑囊侧与未撕裂关节侧肌腱的凋亡基因表达,并以10例肱骨近端骨折髓内钉固定患者肌腱为对照。结果显示两层caspase活性均显著高于对照(P<.05),但两层间无显著差异(P>.05),未撕裂关节层同样存在凋亡增加。作者认为未撕裂关节层异常,治疗该异常层在滑囊侧部分层撕裂中至关重要。

要点

  • 肩袖部分层撕裂未撕裂关节侧肌腱caspase活性显著高于对照(P<.05)。
  • 撕裂滑囊侧与未撕裂关节侧肌腱caspase活性无显著差异(P>.05)。
  • 未撕裂关节层存在凋亡增加,作者认为治疗该异常层至关重要。

核心结论

  • 肩袖部分层撕裂中,凋亡基因表达不仅在撕裂滑囊层升高,在未撕裂关节层也升高。
  • 作者认为未撕裂关节层异常,会引发术后疼痛和进一步肩袖撕裂,因此治疗滑囊侧部分层撕裂中的异常未撕裂关节层至关重要。

研究设计与样本

  • 对照实验室研究,实验组为20例因肩袖部分层撕裂行关节镜手术的患者,从撕裂滑囊侧肌腱和未撕裂关节侧肌腱2个部位取材。
  • 对照组为10例肱骨近端骨折行髓内钉固定时取材的肌腱组织。

主要发现

  • H&E染色显示未撕裂肌腱胶原束方向紊乱,但与对照肌腱相比细胞核形态无差异。
  • TUNEL染色显示未撕裂肌腱与撕裂肌腱相似,均存在细胞凋亡。
  • 免疫组化显示caspase 3、8、9在未撕裂和撕裂肌腱中同步增加。
  • 未撕裂关节层和撕裂滑囊层的所有caspase活性均显著高于对照组(P<.05)。
  • 未撕裂关节层与撕裂滑囊层之间caspase活性无显著差异(P>.05)。

临床怎么用

  • 作者认为,肩袖部分层撕裂的未撕裂关节层异常,会引发术后疼痛和进一步肩袖撕裂,因此治疗滑囊侧部分层撕裂中的异常未撕裂关节层至关重要。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Conversion to full-thickness tear in partial-thickness rotator cuff tears (PTRCTs) is based on the quality and thickness of the normal-looking untorn rotator cuff layer. However, whether the untorn tendon is a healthy tissue remains to be elucidated. PURPOSE: To compare the apoptotic gene expression of the untorn articular layer with the torn bursal layer in PTRCTs. STUDY DESIGN: Controlled laboratory study. METHODS: Tendon tissues were harvested from 20 patients undergoing arthroscopic surgery for partial-thickness rotator cuff repair. As a control group, the tissues were harvested during intramedullary nail fixation in 10 proximal humeral fractures. In the experimental group, the samples were harvested from 2 sites: the torn bursal-sided tendon and the untorn articular-sided tendon. Hematoxylin and eosin (H&E) staining was conducted for basic histological evaluation, and terminal deoxynucleotidyl transferase-mediated dUTP nick end labeling (TUNEL) staining was used to detect apoptosis of tissue cells. The expression of caspase 3, 8, and 9 was confirmed immunohistochemically. Western blot analysis was used to assay the caspase activities. RESULTS: In H&E staining, the direction of collagen bundles in untorn tendon was disoriented when compared with those of control tendon. However, the shape of the nuclei was not different, although the nuclei of the untorn tendon showed apoptosis in the TUNEL staining similar to those of the torn tendon. The immunohistochemical staining of caspase 3, 8, and 9 was increased concomitantly in untorn and torn tendons. All of the caspase activities in the untorn articular layer and torn bursal layer were significantly higher than in controls ( P < .05). However, no significant differences were found between the two layers ( P > .05). CONCLUSION: The study demonstrates that apoptotic gene expression is increased not only in the torn bursal layer but also in the untorn articular layer of PTRCTs. CLINICAL RELEVANCE: The untorn articular layer of PTRCTs is abnormal, which triggers postoperative pain and further rotator cuff tears. Therefore, treatment of the abnormal untorn articular layer is essential in bursal-sided PTRCTs.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Yang H, Lee HJ, Lee YG, et al. Integrity of the Untorn Articular-Sided Tendon in Bursal-Sided Partial-Thickness Rotator Cuff Tear: A Comparative Study of Apoptotic Activity in Torn and Untorn Layers. Am J Sports Med. 2018. PMID: 29975554. doi:10.1177/0363546518782975

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。