文献速递关节外科运动医学

反式全肩关节置换术后肩胛骨切迹:利用患者特异性骨解剖、假体位置和肩关节运动进行预测

Scapular Notching After Reverse Total Shoulder Arthroplasty: Prediction Using Patient-Specific Osseous Anatomy, Implant Location, and Shoulder Motion.
PubMed 文献 · J Bone Joint Surg Am · 2018-01-01

研究纳入29例接受Grammont设计反式全肩关节置换术且有术前CT的患者,术后至少随访2年,结合视频运动分析、术后三维CT和标准X线片,用定制模拟软件确定骨性撞击区域及其与肩胛骨切迹的关系。17例(59%)出现切迹,切迹与盂球安放不够偏下或不够偏后相关;仅需小幅调整假体位置即可避免撞击,提示术前确定理想假体位置可能有助于避免切迹。

要点

  • 17例(59%)出现肩胛骨切迹,均位于肩胛颈后下方,其中3例同时位于前下方。
  • 切迹组盂球下移均值-0.3±3.4 mm vs 无切迹组3.0±2.9 mm(p=0.01),后移均值-0.3±3.5 mm vs 4.2±2.2 mm(p<0.001)。
  • 盂球更偏下(平均3.4±2.3 mm)或更偏外(平均6.2±1.4 mm)可避免多数撞击。

核心结论

  • 利用患者实际术后活动度和假体位置识别的骨性撞击与影像学肩胛骨切迹位置相符。
  • 盂球偏下、偏外和偏后均是避免切迹的重要因素,仅需小幅改变假体位置即可避免撞击,提示术前确定理想假体位置可能是有助于避免切迹的手术规划工具。

研究设计与样本

  • 29例有术前CT、接受Grammont设计反式全肩关节置换术的患者,术后至少随访2年,接受视频运动分析、术后三维CT和标准X线片评估。
  • 将视频运动分析显示的盂肱活动度和CT上的术后假体位置输入定制模拟软件,确定肱骨假体与肩胛骨之间的骨性撞击区域及其与术后CT肩胛骨切迹的关系。
  • 有切迹与无切迹患者通过单变量和多变量分析比较,以确定与切迹相关的因素。

主要发现

  • 17例(59%)出现肩胛骨切迹,全部沿肩胛颈后下方,其中3例沿肩胛颈前下方。
  • 骨性撞击发生于16/17例手臂垂于体侧的外旋、3例手臂垂于体侧的内旋和12例外展。
  • 其余12例患者无切迹或骨性撞击。
  • 切迹与盂球安放不够偏下相关(切迹组下移均值-0.3±3.4 mm vs 无切迹组3.0±2.9 mm;p=0.01),也与盂球安放不够偏后相关(均值-0.3±3.5 mm vs 4.2±2.2 mm;p<0.001)。

关键数值与推荐

  • 双变量模型显示盂球偏下和偏后(AUC 0.887;p<0.001)、偏下和偏外(AUC 0.892;p<0.001)、偏后和偏外(AUC 0.892;p<0.001)位置是避免肩胛骨切迹能力的显著预测因素。
  • 将盂球安放得更偏下(平均3.4±2.3 mm)或更偏外(平均6.2±1.4 mm)可避免患者给定活动度下的多数撞击。

临床怎么用

  • 作者认为,使用该假体设计时,术前确定理想假体位置可能是有助于避免切迹的手术规划工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Scapular notching is frequently observed following reverse total shoulder arthroplasty (rTSA), although the etiology is not well understood. METHODS: Twenty-nine patients with preoperative computed tomography (CT) scans who underwent rTSA with a Grammont design were evaluated after a minimum of 2 years of follow-up with video motion analysis (VMA), postoperative three-dimensional (3D) CT, and standard radiographs. The glenohumeral range of motion demonstrated by the VMA and the postoperative implant location on the CT were used in custom simulation software to determine areas of osseous impingement between the humeral implant and the scapula and their relationship to scapular notching on postoperative CT. Patients with and without notching were compared with one another by univariable and multivariable analyses to determine factors associated with notching. RESULTS: Seventeen patients (59%) had scapular notching, which was along the posteroinferior aspect of the scapular neck in all of them and along the anteroinferior aspect of the neck in 3 of them. Osseous impingement occurred in external rotation with the arm at the side in 16 of the 17 patients, in internal rotation with the arm at the side in 3, and in adduction in 12. The remaining 12 patients did not have notching or osseous impingement. Placing the glenosphere in a position that was more inferior (by a mean of 3.4 ± 2.3 mm) or lateral (by a mean of 6.2 ± 1.4 mm) would have avoided most impingement in the patients' given range of motion. Notching was associated with glenosphere placement that was insufficiently inferior (mean inferior translation, -0.3 ± 3.4 mm in the notching group versus 3.0 ± 2.9 mm in the no-notching group; p = 0.01) or posterior (mean, -0.3 ± 3.5 mm versus 4.2 ± 2.2 mm; p < 0.001). Two-variable models showed inferior and posterior (area under the curve [AUC], 0.887; p < 0.001), inferior and lateral (AUC, 0.892; p < 0.001), and posterior and lateral (AUC, 0.892; p < 0.001) glenosphere positions to be significant predictors of the ability to avoid scapular notching. CONCLUSIONS: Osseous impingement identified using patients' actual postoperative range of motion and implant position matched the location of scapular notching seen radiographically. Inferior, lateral, and posterior glenosphere positions are all important factors in the ability to avoid notching. Only small changes in implant position were needed to avoid impingement, suggesting that preoperative determination of the ideal implant position may be a helpful surgical planning tool to avoid notching when using this implant design. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Kolmodin J, Davidson IU, Jun BJ, et al. Scapular Notching After Reverse Total Shoulder Arthroplasty: Prediction Using Patient-Specific Osseous Anatomy, Implant Location, and Shoulder Motion. J Bone Joint Surg Am. 2018. PMID: 29975263. doi:10.2106/JBJS.17.00242

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。