文献速递关节外科

金属对聚乙烯全髋关节置换术头颈锥度腐蚀翻修术后早期并发症的相关风险因素

Risk Factors Associated With Early Complications of Revision Surgery for Head-Neck Taper Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2018-06-09

本研究评估了39例金属对聚乙烯全髋关节置换术患者因头颈锥度腐蚀行翻修术的早期并发症与结局,共40次连续翻修。总体并发症率为25%,再手术率为10%。翻修前MRI显示实性病灶伴外展肌缺陷及术中组织损伤与翻修术后并发症显著相关。

要点

  • 金属对聚乙烯全髋关节置换术头颈锥度腐蚀翻修术后早期并发症率为25%,再手术率为10%。
  • 翻修前MRI显示实性病灶伴外展肌缺陷与翻修术后并发症显著相关(P < .01)。
  • 术中组织损伤与翻修术后并发症显著相关(P = .02)。

核心结论

  • 金属对聚乙烯全髋关节置换术头颈锥度腐蚀相关不良局部组织反应翻修术后早期并发症率高(25%),再翻修率为10%。
  • 翻修前MRI显示实性病灶伴外展肌缺陷和术中组织损伤是与翻修术后并发症发生相关的风险因素。

研究设计与样本

  • 对39例(男16例,女23例)金属对聚乙烯全髋关节置换术患者共40次连续翻修手术进行评估。
  • 翻修术后随访时间至少14个月(范围14-45个月)。
  • 翻修手术指征为MRI上存在症状性不良局部组织反应且金属离子水平升高。

主要发现

  • 总体并发症率为25%,再手术率为10%。
  • 翻修前血清钴离子中位水平为8.2 μg/L(范围1.2-56.1 μg/L),翻修后降至3.1 μg/L(范围0.2-14.0 μg/L),差异有统计学意义(P < .01)。
  • 82%的取出植入物中观察到高摩擦腐蚀分级(Goldberg评分≥3)。
  • MRI显示实性病灶伴外展肌缺陷与翻修术后并发症显著相关(P < .01)。
  • 术中组织损伤与翻修术后并发症显著相关(P = .02)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Adverse local tissue reactions (ALTRs) due to tribocorrosion of head-neck taper junctions in contemporary metal-on-polyethylene (MoP) total hip arthroplasty (THA) are emerging as an important reason for failure requiring revision surgery. This study aimed at: (1) reporting early complication rates and outcome, and (2) identifying risk factors associated with complications of revision surgery for head-neck taper corrosion in patients with MoP THA. METHODS: Forty consecutive revision surgeries in 39 patients (male, 16; female, 23) with MoP THA were evaluated. The follow-up period after revision was a minimum of 14 months (range, 14-45). The indication for revision surgery was the presence of symptomatic ALTR on magnetic resonance imaging (MRI) with elevated metal ion levels. RESULTS: The overall complication rate was 25% and the reoperation rate was 10%. The median serum level of cobalt ions decreased significantly 8.2 μg/L (1.2-56.1 μg/L) pre-revision to 3.1 μg/L (0.2-14.0 μg/L) post-revision (P < .01). High fretting and corrosion grades (Goldberg score ≥ 3) were observed in 82% of retrieved implants. MRI findings of solid lesion(s) with abductor deficiency (P < .01) and intraoperative tissue damage at revision (P = .02) were significantly associated with post-revision complications. CONCLUSION: A high rate of early complications (25%) and re-revisions (10%) was observed after revision of ALTR associated with head-neck taper corrosion. Pre-revision MRI findings of solid lesion(s) with abductor deficiency and intraoperative tissue damage were risk factors associated with the occurrence of a complication after revision surgery. This information provides clinically useful information for clinical decision-making and preoperative counseling of MoP THA patients undergoing revision surgery for head-neck taper corrosion.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kwon YM, Rossi D, MacAuliffe J, et al. Risk Factors Associated With Early Complications of Revision Surgery for Head-Neck Taper Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty. 2018. PMID: 29958755. doi:10.1016/j.arth.2018.05.046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。