文献速递关节外科

骨关节炎患者机器人植入全髋关节置换术中自体股骨颈前倾角与最终股骨柄前倾角变异性评估

Evaluation of Native Femoral Neck Version and Final Stem Version Variability in Patients With Osteoarthritis Undergoing Robotically Implanted Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2018-06-28

这项多中心研究纳入362例接受机器人植入全髋关节置换术的骨关节炎患者,用CT规划测量股骨颈前倾角(FNV)、术中测量股骨柄前倾角(SV)、髋臼假体前倾角(AV)与联合前倾角(CV)。结果示FNV均值5.0°±9.6°、SV均值6.4°±9.7°,二者中度相关(R=0.48,P<.001),SV与CV强相关(R=0.89,P<.001);SV<5°时CV<25°的相对风险为8.6倍(P<.001)。作者认为使用非骨水泥单楔形直柄时SV变异大,低SV难以纠正。

要点

  • FNV均值5.0°±9.6°,SV均值6.4°±9.7°,二者差值平均1.6°±9.8°。
  • FNV与SV中度相关(R=0.48,P<.001),SV与CV强相关(R=0.89,P<.001)。
  • SV<5°时CV<25°的相对风险为8.6倍(P<.001)。

核心结论

  • 使用非骨水泥单楔形直柄时,股骨柄前倾角(SV)变异很大。
  • SV与自体股骨颈前倾角(FNV)中度相关,但SV可部分受术者影响。
  • 低SV难以纠正,带来低联合前倾角(CV)的高风险。

研究设计与样本

  • 多中心研究,纳入2012年至2016年3个骨科中心的362例接受全髋关节置换术的患者。
  • 所有患者接受CT规划测量股骨颈前倾角(FNV),并用机器人器械术中测量股骨柄前倾角(SV)、髋臼假体前倾角(AV)与联合前倾角(CV)。

主要发现

  • FNV均值5.0°±9.6°,SV均值6.4°±9.7°,FNV与SV平均差值1.6°±9.8°。
  • FNV与SV中度相关(R=0.48,P<.001);SV与CV强相关(R=0.89,P<.001)。
  • SV在5°至20°之间的患者有174例(48%)。
  • CV均值28.2°±7.9°;CV<25°的患者有109例(30.1%)。
  • 3个中心之间SV存在显著差异(P<.001);SV<5°时CV<25°的相对风险为8.6倍(P<.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Combined anteversion in total hip arthroplasty influences both dislocation risk and range of motion. One of its components, stem version (SV), could be dictated by many factors, from native femoral anatomy to stem geometry and surgeon's choice. In the present multicenter study, robotic technology was used to assess the influence of native femoral version on final SV and combined anteversion using a straight, uncemented stem. METHODS: Three hundred sixty-two patients undergoing total hip arthroplasty were enrolled from 3 different orthopedic centers from 2012 and 2016. All patients underwent computed tomography planning with measurement of femoral neck version (FNV) and intraoperative measurement of stem version (SV), acetabular component version (AV), and combined version (CV) with robotic instrumentation. RESULTS: Mean FNV was 5.0° ± 9.6°, and SV was 6.4° ± 9.7°. The average difference between FNV and SV was 1.6° ± 9.8°. A moderate correlation was found between FNV and SV (R = 0.48, P < .001). SV was between 5° and 20° in 174 patients (48%). Mean CV was 28.2° ± 7.9°. A strong correlation was found between SV and CV (R = 0.89, P < .001). A significant difference in SV was found between the 3 centers (P < .001). CV was <25° in 109 patients (30.1%). Relative risk of CV < 25° was 8.6 times greater with SV < 5° (P < .001). CONCLUSION: With the use of an uncemented, single-wedge, straight stem, SV is highly variable. Despite being moderately correlated with native FNV, SV can be partially influenced by the surgeon. A low SV could be hardly corrected, bringing high risk of low CV.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Marcovigi A, Ciampalini L, Perazzini P, et al. Evaluation of Native Femoral Neck Version and Final Stem Version Variability in Patients With Osteoarthritis Undergoing Robotically Implanted Total Hip Arthroplasty. J Arthroplasty. 2018. PMID: 30017219. doi:10.1016/j.arth.2018.06.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。