文献速递关节外科

计算机导航对单髁膝关节置换术后并发症发生率的影响

Effect of Computer Navigation on Complication Rates Following Unicompartmental Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2018-06-30

基于2005至2014年Medicare数据库,比较1025例导航单髁膝关节置换与9228例年龄性别匹配的非导航单髁膝关节置换。导航组与非导航组在2年转为全膝关节置换率(3.8% vs 4.7%,P=0.218)、2年膝关节切开术率(1.3% vs 1.6%,P=0.379)及90天深静脉血栓率(1.4% vs 2.0%,P=0.157)均无显著差异。

要点

  • 导航单髁膝关节置换2年转为全膝关节置换率为3.8%,非导航组为4.7%,差异无统计学意义(P=0.218)。
  • 导航组2年膝关节切开术率为1.3%,非导航组为1.6%,差异无统计学意义(P=0.379)。
  • 导航组90天深静脉血栓率为1.4%,非导航组为2.0%,差异无统计学意义(P=0.157)。

核心结论

  • 导航单髁膝关节置换与非导航单髁膝关节置换在并发症和翻修率上无显著差异,尤其转为全膝关节置换率无差异,该结果与临床决策直接相关。

研究设计与样本

  • 基于2005至2014年Medicare数据库的行政索赔数据,纳入接受单次单髁膝关节置换且随访至少2年的患者。
  • 比较1025例导航单髁膝关节置换与9228例年龄和性别匹配的非导航单髁膝关节置换。
  • 使用国际疾病分类第九版编码识别术后并发症,并在30天、90天和2年进行评估。

主要发现

  • 2年随访时,导航组转为全膝关节置换率为3.8%,非导航组为4.7%,P=0.218。
  • 2年随访时,导航组膝关节切开术率为1.3%,非导航组为1.6%,P=0.379。
  • 90天随访时,导航组深静脉血栓率为1.4%,非导航组为2.0%,P=0.157。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We evaluated whether the complication and revision rates of unicompartmental knee arthroplasty (UKA) performed with intraoperative computer-based navigation differ from standard UKAs performed without intraoperative computer-based navigation. METHODS: A Medicare database containing administrative claims data from 2005 to 2014 was queried. Patients who underwent a single UKA and had a minimum of 2 years of follow-up were included in the study. Data from 1025 UKAs performed with navigation were compared against 9228 age and gender-matched UKAs performed without it. Postoperative complications were identified using International Classification of Diseases, Ninth Revision, codes and evaluated at 30 days, 90 days, and 2 years. RESULTS: Orthopedic complications after UKA are rare, and the use of navigation did not affect the rate of conversion to total knee arthroplasty at 2-year follow-up (3.8% in navigated UKAs vs 4.7% in standard UKAs, P = .218). There were also no significant differences in the rates of knee arthrotomy at 2-year follow-up (1.3% in navigated UKAs vs 1.6% in standard UKAs, P = .379). The rates of deep vein thrombosis at 90-day follow-up did not significantly differ between the 2 groups (1.4% in navigated UKAs vs 2.0% in standard UKAs, P = .157). CONCLUSION: This is one of the first studies to use a large cohort to compare outcomes in computer-assisted surgery-UKA against standard UKAs without navigation. The results, particularly that there was not a difference in the rate of conversion to total knee arthroplasty, are directly relevant to clinical decision-making when surgeons are considering employing navigation during UKA.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Chona D, Bala A, Huddleston JI, et al. Effect of Computer Navigation on Complication Rates Following Unicompartmental Knee Arthroplasty. J Arthroplasty. 2018. PMID: 30033063. doi:10.1016/j.arth.2018.06.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。