股骨假体与髋臼假体的配合:股骨前倾角与联合前倾角对交联聚乙烯磨损的影响

Femoral-Acetabular Mating: The Effect of Femoral and Combined Anteversion on Cross-Linked Polyethylene Wear.
PubMed 文献 · J Arthroplasty · 2018-06-13

研究纳入36例患者共42髋初次全髋关节置换,由单一术者经后路完成,随访至少5年(平均7.1年),采用经验证的计算机辅助边缘检测算法测量交联聚乙烯线性磨损。股骨前倾角与线性磨损显著相关,呈倒抛物线关系,前倾角约18.2°时磨损最小(P=0.02);联合前倾角同样显著相关,约38.1°时磨损最小(P<0.001)。

要点

  • 股骨前倾角与交联聚乙烯线性磨损显著相关,约18.2°时磨损最小(P=0.02)。
  • 联合前倾角与线性磨损显著相关,约38.1°时磨损最小(P<0.001)。
  • 联合前倾角24.6°至50.4°范围内线性磨损率低于0.1 mm/y。

核心结论

  • 作者认为这是首个将股骨前倾角确定为影响交联聚乙烯磨损独立因素的研究,磨损最小出现在约18°。
  • 在5至10年随访中,联合前倾角25°至50°范围内交联聚乙烯平均线性磨损低于0.1 mm/y,磨损最小在约38°。
  • 股骨假体与髋臼假体的配合是两者共同作用的结果,股骨假体前倾角和联合前倾角对磨损的影响大于髋臼假体外倾角。
  • 作者指出需要进一步研究,但认为这些结果表明结合前倾角评估可提高磨损研究的敏感性。

研究设计与样本

  • 由单一术者经后路完成的42髋初次全髋关节置换(36例患者),随访至少5年(平均7.1年,范围5.0-10.3年)。
  • 所有髋均使用模块化交联聚乙烯内衬,轴承直径≥36 mm。
  • 股骨前倾角在改良Budin位X线片上测量,磨损采用经验证的计算机辅助边缘检测算法在X线片上测量。
  • 采用线性和多项式回归分析评估股骨前倾角和联合前倾角对交联聚乙烯磨损的影响。

主要发现

  • 平均髋臼假体外倾角为40.4°(范围22.6°-50.3°),平均髋臼假体前倾角为19.1°(范围11.3°-27.5°),两者均与磨损无显著相关性。
  • 股骨前倾角平均18.4°(范围6.8°-30.7°),与线性磨损(平均0.06 mm/y,范围0-0.16)显著相关,呈倒抛物线关系,磨损最小在18.2°(P=0.02)。
  • 联合前倾角平均37.2°(范围21.8°-54.3°),与线性磨损呈类似显著关系,磨损最小在38.1°(P<0.001)。
  • 基于回归分析,联合前倾角在24.6°至50.4°之间时线性磨损率低于0.1 mm/y。

关键数值与推荐

  • 股骨前倾角与线性磨损呈倒抛物线关系,磨损最小在18.2°(P=0.02)。
  • 联合前倾角与线性磨损显著相关,磨损最小在38.1°(P<0.001)。
  • 联合前倾角在24.6°至50.4°之间时线性磨损率低于0.1 mm/y。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 作者指出需要进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Cross-linked polyethylene (XLPE) has generally low rates of wear and osteolysis at 10 years, but component position may become important with longer follow-up. At 5-13 years, neither acetabular component lateral opening angle nor version were significantly correlated to wear. In the present study, we analyzed the effects of femoral anteversion and combined anteversion on XLPE wear. METHODS: Forty-two well-functioning primary total hip arthroplasties in 36 patients, performed by a single surgeon via a posterior approach, were followed for a minimum of 5 years (mean, 7.1 years; range, 5.0-10.3). All hips had a modular, XLPE liner with a ≥36-mm bearing. Femoral anteversion was measured on the modified Budin view. Wear was measured on radiographs using a validated, computer-assisted, edge-detection-based algorithm. The mean lateral opening angle was 40.4° (range, 22.6°-50.3°). The mean acetabular version was 19.1° (range, 11.3°-27.5°). Neither of these variables was significantly correlated to wear. Effects of femoral anteversion and combined anteversion on XLPE wear were assessed using linear and polynomial regression analysis. RESULTS: Femoral anteversion (mean, 18.4°; range, 6.8°-30.7°) was significantly correlated to linear wear (mean, 0.06 mm/y; range, 0-0.16), showing an inverse parabolic relationship with the least wear occurring at 18.2° (P = .02). Combined anteversion (mean, 37.2°; range, 21.8°-54.3°) showed a similar significant relationship with the least wear at 38.1° (P < .001). Based on regression, combined anteversion between 24.6° and 50.4° resulted in linear wear rates less than 0.1 mm/y. CONCLUSION: To the authors' knowledge, this is the first study to identify femoral anteversion as an independent factor influencing XLPE wear, with least wear occurring around 18°. At 5-10 years, average linear wear of XLPE is below 0.1 mm/y over a 25°-50° range of combined anteversion, with the least wear around 38°. Femoral-acetabular mating is a product of both components. Femoral component version and combined anteversion had a greater effect on wear than acetabular component lateral opening angle. Additional studies are warranted, but these results indicate that the sensitivity of wear studies is increased with version assessments.