文献速递小儿骨科

新生儿筛查与选择性超声影像在发育性髋关节发育不良诊断中的应用

Neonatal screening and selective sonographic imaging in the diagnosis of developmental dysplasia of the hip.
PubMed 文献 · Bone Joint J · 2018-01-01

这项前瞻性队列研究对四年新生儿髋关节筛查项目进行观察评估,所有新生儿在出生72小时内接受Barlow或Ortolani手法检查,阳性者转诊至一站式筛查门诊进行临床和超声评估。共124名新生儿转诊,5例发现临床髋关节不稳定,超声显示92例Graf I型、12例Graf II型、20例Graf IV型。临床筛查阳性预测值为4.0%,超声阳性预测值为16.1%,并导致DDH手术率增加。与既往10年和15年研究相比,转诊者阳性预测值明显下降,呈现转诊增加、阳性预测值下降与手术率增加的矛盾现象。

要点

  • 所有新生儿在出生72小时内接受Barlow或Ortolani手法检查,阳性者转诊至一站式筛查门诊。
  • 124名转诊新生儿中,临床筛查阳性预测值为4.0%,超声阳性预测值为16.1%。
  • 与既往10年和15年研究相比,转诊者阳性预测值明显下降,同时DDH手术率增加。

核心结论

  • 与既往发表的10年和15年研究相比,因潜在髋关节不稳定而转诊者的阳性预测值明显下降。
  • 存在矛盾现象:转诊增加、阳性预测值下降,同时新生儿发育性髋关节发育不良的手术率增加。

研究设计与样本

  • 前瞻性队列研究,对四年新生儿髋关节筛查项目进行观察评估。
  • 所有新生儿在出生72小时内接受Barlow或Ortolani手法检查,阳性发现者转诊至一站式筛查门诊进行临床和超声评估。
  • 结果与本单位既往发表的研究进行比较。

主要发现

  • 共124名新生儿因Barlow或Ortolani手法阳性、弹响阳性或「不稳定」而转诊。
  • 5名新生儿发现临床髋关节不稳定。
  • 超声检查显示92名新生儿为Graf I型髋,12名为Graf II型髋,20名为Graf IV型髋。
  • 临床筛查的阳性预测值为4.0%,超声的阳性预测值为16.1%。
  • 上述结果导致DDH手术率增加。

关键数值与推荐

  • 临床筛查阳性预测值为4.0%。
  • 超声阳性预测值为16.1%。
  • 124名转诊新生儿中,5名发现临床髋关节不稳定。
  • 超声分型:Graf I型92名,Graf II型12名,Graf IV型20名。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this prospective cohort study was to evaluate the effectiveness of the neonatal hip instability screening programme. PATIENTS AND METHODS: The study involved a four-year observational assessment of a neonatal hip screening programme. All newborns were examined using the Barlow or Ortolani manoeuvre within 72 hours of birth; those with positive findings were referred to a 'one-stop' screening clinic for clinical and sonographic assessment of the hip. The results were compared with previous published studies from this unit. RESULTS: A total of 124 newborns with a positive Barlow or Ortolani manoeuvre, clunk positive, or 'unstable' were referred. Five were found to have clinical instability of the hip. Sonographically, 92 newborns had Graf Type I hips, 12 had Graf Type II hips, and 20 had Graf Type IV hips. The positive predictive value (PPV) of clinical screening was 4.0% and the PPV of sonography was 16.1%. This has led to an increased rate of surgery for DDH. CONCLUSION: Compared with previously published ten-year and 15-year studies, there has been a marked deterioration in the PPV in those referred with potential instability of the hip. There appears to be a paradox, with rising referrals and a decreasing PPV combined with an increasing rate of surgery in newborns with developmental dysplasia of the hip. Cite this article: Bone Joint J 2018;100-B:806-10.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Choudry QA, Paton RW. Neonatal screening and selective sonographic imaging in the diagnosis of developmental dysplasia of the hip. Bone Joint J. 2018. PMID: 29855244. doi:10.1302/0301-620X.100B6.BJJ-2017-1389.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。