文献速递关节外科

金属对聚乙烯全髋关节置换术后因不良局部组织反应行翻修术与早期重大并发症高风险相关

Revision for adverse local tissue reaction following metal-on-polyethylene total hip arthroplasty is associated with a high risk of early major complications.
PubMed 文献 · Bone Joint J · 2018-01-01

研究纳入33例因锥部磨损(trunnionosis)导致金属对聚乙烯全髋关节置换术后不良局部组织反应(ARMD)而行翻修的患者,均更换为带钛套的陶瓷头。翻修后6例(18.2%)脱位、3例(9.1%)深部感染、6例(18.2%)持续疼痛,1例股动脉血栓。作者认为此类翻修严重并发症风险高,广泛组织损伤时推荐使用限制性内衬或双动构造。

要点

  • 33例金属对聚乙烯全髋因锥部磨损致ARMD翻修,均更换为带钛套陶瓷头。
  • 翻修后6例(18.2%)脱位,其中4例需再次翻修。
  • 3例(9.1%)深部感染,6例(18.2%)无明确原因的持续疼痛。

核心结论

  • 金属对聚乙烯全髋关节置换术后因锥部磨损相关ARMD行翻修术,严重并发症风险高。
  • 作者建议:存在广泛组织损伤时,此类患者推荐使用限制性内衬或双动构造。

研究设计与样本

  • 共识别36例因锥部磨损导致ARMD而行翻修的金属对聚乙烯全髋关节置换患者,排除3例翻修至另一金属头者。
  • 其余33例翻修至带钛套的陶瓷头,描述其表现、翻修所见及并发症风险。

主要发现

  • 患者表现为疼痛、肿胀、僵硬或不稳,影像学确认炎性肿块。
  • 所有患者均见锥部宏观材料沉积,与ARMD相关。
  • 翻修后6例(18.2%)脱位,其中4例需进一步翻修。
  • 3例(9.1%)发生深部感染,6例(18.2%)有显著持续疼痛且无明确原因。
  • 1例在切除髂股假性肿瘤后发生股动脉血栓,需血栓切除术。

临床怎么用

  • 作者建议:存在广泛组织损伤时,此类患者推荐使用限制性内衬或双动构造。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Fretting and corrosion at the modular head/neck junction, known as trunnionosis, in total hip arthroplasty (THA) is a cause of adverse reaction to metal debris (ARMD). We describe the outcome of revision of metal-on-polyethylene (MoP) THA for ARMD due to trunnionosis with emphasis on the risk of major complications. PATIENTS AND METHODS: A total of 36 patients with a MoP THA who underwent revision for ARMD due to trunnionosis were identified. Three were excluded as their revision had been to another metal head. The remaining 33 were revised to a ceramic head with a titanium sleeve. We describe the presentation, revision findings, and risk of complications in these patients. RESULTS: The patients presented with pain, swelling, stiffness, or instability and an inflammatory mass was confirmed radiologically. Macroscopic material deposition on the trunnion was seen in all patients, associated with ARMD. Following revision, six (18.2%) dislocated, requiring further revision in four. Three (9.1%) developed a deep infection and six (18.2%) had significant persistent pain without an obvious cause. One developed a femoral artery thrombosis after excision of an iliofemoral pseudotumor, requiring a thrombectomy. CONCLUSION: The risk of serious complications following revision MoP THA for ARMD associated with trunnionosis is high. In the presence of extensive tissue damage, a constrained liner or dual mobility construct is recommended in these patients. Cite this article: Bone Joint J 2018;100-B:720-4.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Waterson HB, Whitehouse MR, Greidanus NV, et al. Revision for adverse local tissue reaction following metal-on-polyethylene total hip arthroplasty is associated with a high risk of early major complications. Bone Joint J. 2018. PMID: 29855241. doi:10.1302/0301-620X.100B6.BJJ-2017-1466.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。