文献速递关节外科

使用倾角仪能否改善全髋关节置换术中髋臼假体的定位

Can the use of an inclinometer improve the positioning of the acetabular component in total hip arthroplasty?
PubMed 文献 · Bone Joint J · 2018-01-01

本研究回顾了167例由同一术者施行的初次全髋关节置换术,最终纳入120例,比较使用倾角仪(68例)与不使用倾角仪(52例)对髋臼假体倾斜角的影响。结果显示倾角仪组平均倾斜角为42.9°,对照组为46.5°,差异有统计学意义(p<0.001),不使用倾角仪者倾斜角>50°的风险约为使用者的三倍(OR 2.8,p=0.036)。作者结论认为使用简易倾角仪可显著减少倾斜角超出安全区的例数。

要点

  • 倾角仪组髋臼假体平均倾斜角为42.9°(95%CI 41.7°至44.0°),对照组为46.5°(95%CI 45.2°至47.7°),p<0.001。
  • 回归分析显示使用倾角仪使倾斜角差异为9.1%(p<0.001)。
  • 不使用倾角仪者倾斜角>50°的风险约为使用者的三倍(OR 2.8,p=0.036)。

核心结论

  • 与徒手技术相比,使用简易倾角仪可显著减少髋臼假体倾斜角超出安全区的例数。

研究设计与样本

  • 回顾性 review 了14个月内由同一术者施行的167例初次全髋关节置换术,最终纳入120例,其中倾角仪组68例、对照组52例。
  • 手术在两个机构进行:住院医院使用倾角仪(倾角仪组),门诊中心不使用倾角仪(对照组),原因为倾角仪无法充分灭菌。
  • 排除47例BMI>40 kg/m2、年龄>68岁或手术指征非骨关节炎且无法在门诊中心治疗的患者。
  • 倾斜角由两名未参与手术的盲法研究者从去标识化X线平片上测量,采用多因素回归分析评估倾角仪使用对倾斜角的影响。

主要发现

  • 倾角仪组平均倾斜角为42.9°(95%CI 41.7°至44.0°;范围29.0°至63.8°),对照组为46.5°(95%CI 45.2°至47.7°;范围32.8°至63.2°),p<0.001。
  • 回归分析显示使用倾角仪导致的倾斜角差异为9.1%(p<0.001)。
  • 不使用倾角仪的全髋关节置换术出现倾斜角>50°的可能性为使用者的三倍(OR 2.8,p=0.036)。
  • 两名研究者测量值的观察者间信度相关系数为0.95(95%CI 0.93至0.97)。

关键数值与推荐

  • 髋臼假体倾斜角安全区定义为30°至50°。
  • 不使用倾角仪者倾斜角>50°的OR为2.8(p=0.036)。

临床怎么用

  • 原文结论认为使用简易倾角仪可显著减少倾斜角超出安全区的例数,未给出具体临床操作推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Accurate placement of the acetabular component is essential in total hip arthroplasty (THA). The purpose of this study was to determine if the ability to achieve inclination of the acetabular component within the 'safe-zone' of 30° to 50° could be improved with the use of an inclinometer. PATIENTS AND METHODS: We reviewed 167 primary THAs performed by a single surgeon over a period of 14 months. Procedures were performed at two institutions: an inpatient hospital, where an inclinometer was used (inclinometer group); and an ambulatory centre, where an inclinometer was not used as it could not be adequately sterilized (control group). We excluded 47 patients with a body mass index (BMI) of > 40 kg/m2, age of > 68 years, or a surgical indication other than osteoarthritis whose treatment could not be undertaken in the ambulatory centre. There were thus 120 patients in the study, 68 in the inclinometer group and 52 in the control group. The inclination angles of the acetabular component were measured from de-identified plain radiographs by two blinded investigators who were not involved in the surgery. The effect of the use of the inclinometer on the inclination angle was determined using multivariate regression analysis. RESULTS: The mean inclination angle for the THAs in the inclinometer group was 42.9° (95% confidence interval (CI) 41.7° to 44.0°; range 29.0° to 63.8°) and 46.5° (95% CI 45.2° to 47.7°; range 32.8° to 63.2°) in the control group (p < 0.001). Regression analysis identified a 9.1% difference in inclination due to the use of an inclinometer (p < 0.001), and THAs performed without the inclinometer were three times more likely to result in inclination angles of > 50° (odds ratio (OR) 2.8, p = 0.036). The correlation coefficient for the interobserver reliability of the measurement of the two investigators was 0.95 (95% CI 0.93 to 0.97). CONCLUSION: The use of a simple inclinometer resulted in a significant reduction in the number of outliers compared with a freehand technique. Cite this article: Bone Joint J 2018;100-B:862-6.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Darrith B, Bell JA, Culvern C, et al. Can the use of an inclinometer improve the positioning of the acetabular component in total hip arthroplasty? Bone Joint J. 2018. PMID: 29954211. doi:10.1302/0301-620X.100B7.BJJ-2017-1607.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。